Core losses of an inverter-fed permanent magnet synchronous motor with an amorphous stator core under no-load

In this paper, an interior permanent magnet synchronous motor (IPMSM) with a stator core made of amorphous magnetic material (AMM) is presented. The IPMSM is driven by a voltage source three-phase inverter with classical pulse width modulation (PWM) control. The core losses under no-load condition a...

Full description

Bibliographic Details
Main Authors: Nicolas Denis, Yoshiyuki Kato, Masaharu Ieki, Keisuke Fujisaki
Format: Article
Language:English
Published: AIP Publishing LLC 2016-05-01
Series:AIP Advances
Online Access:http://dx.doi.org/10.1063/1.4943361
Description
Summary:In this paper, an interior permanent magnet synchronous motor (IPMSM) with a stator core made of amorphous magnetic material (AMM) is presented. The IPMSM is driven by a voltage source three-phase inverter with classical pulse width modulation (PWM) control. The core losses under no-load condition are measured by experiment and compared to an equivalent IPMSM with a stator core made of NO steel. Under these conditions, the core losses are influenced by the stator, rotor and magnet shapes but also by the PWM carrier signal that implies a high frequency harmonic in the magnetic flux density. It is demonstrated that the AMM can reduce the core losses by about 56 %.
ISSN:2158-3226