Effect of using immobilization device in fluoroscopic study in pediatric patient: Focused on radiation dose reduction in voiding cystourethrogram.

INTRODUCTION:To prove objective effect of using mechanical device for immobilization of pediatric patient during voiding cystourethrogram (VCUG) compare immobilization by hand-holding. METHODS:This study included 77 patients, who underwent VCUG in our center from April to October 2017, who had a cli...

Full description

Bibliographic Details
Main Authors: Hyun-Hae Cho, So Mi Lee, Sun Kyoung You
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2019-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0224063
id doaj-1e230559aae044c593bc7ece8d613060
record_format Article
spelling doaj-1e230559aae044c593bc7ece8d6130602021-03-03T21:14:00ZengPublic Library of Science (PLoS)PLoS ONE1932-62032019-01-011410e022406310.1371/journal.pone.0224063Effect of using immobilization device in fluoroscopic study in pediatric patient: Focused on radiation dose reduction in voiding cystourethrogram.Hyun-Hae ChoSo Mi LeeSun Kyoung YouINTRODUCTION:To prove objective effect of using mechanical device for immobilization of pediatric patient during voiding cystourethrogram (VCUG) compare immobilization by hand-holding. METHODS:This study included 77 patients, who underwent VCUG in our center from April to October 2017, who had a clinically suspicious urinary tract infection. Patients were classified into one of two groups based on whether examination was done before (Group A) or after (Group B) adaptation of immobilization device. Patient-related data, image quality related score and dose-related data were collected and compared between two groups. RESULTS:Group A included 36 patients and group B included 41. Patient related data including mean age, sex, body weight and height didn't show significant difference between two groups (p > 0.05 for all). Among the image quality scoring, overall image quality, motion artifact, showed significant difference between two groups with improved inadequate timing and centering after adaptation of immobilization device. Dose related data showed significantly decreased shot number, mean fluoroscopic time with decreased mean dose area product (DAP) value and effective dose after adaptation of immobilization device (p < 0.05 for all). CONCLUSION:Adaptation of immobilization device can improve overall image quality with decreased motion artifact and improved centering and timing with even shot number, mean fluoroscopic time with decreased mean DAP value and effective dose.https://doi.org/10.1371/journal.pone.0224063
collection DOAJ
language English
format Article
sources DOAJ
author Hyun-Hae Cho
So Mi Lee
Sun Kyoung You
spellingShingle Hyun-Hae Cho
So Mi Lee
Sun Kyoung You
Effect of using immobilization device in fluoroscopic study in pediatric patient: Focused on radiation dose reduction in voiding cystourethrogram.
PLoS ONE
author_facet Hyun-Hae Cho
So Mi Lee
Sun Kyoung You
author_sort Hyun-Hae Cho
title Effect of using immobilization device in fluoroscopic study in pediatric patient: Focused on radiation dose reduction in voiding cystourethrogram.
title_short Effect of using immobilization device in fluoroscopic study in pediatric patient: Focused on radiation dose reduction in voiding cystourethrogram.
title_full Effect of using immobilization device in fluoroscopic study in pediatric patient: Focused on radiation dose reduction in voiding cystourethrogram.
title_fullStr Effect of using immobilization device in fluoroscopic study in pediatric patient: Focused on radiation dose reduction in voiding cystourethrogram.
title_full_unstemmed Effect of using immobilization device in fluoroscopic study in pediatric patient: Focused on radiation dose reduction in voiding cystourethrogram.
title_sort effect of using immobilization device in fluoroscopic study in pediatric patient: focused on radiation dose reduction in voiding cystourethrogram.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2019-01-01
description INTRODUCTION:To prove objective effect of using mechanical device for immobilization of pediatric patient during voiding cystourethrogram (VCUG) compare immobilization by hand-holding. METHODS:This study included 77 patients, who underwent VCUG in our center from April to October 2017, who had a clinically suspicious urinary tract infection. Patients were classified into one of two groups based on whether examination was done before (Group A) or after (Group B) adaptation of immobilization device. Patient-related data, image quality related score and dose-related data were collected and compared between two groups. RESULTS:Group A included 36 patients and group B included 41. Patient related data including mean age, sex, body weight and height didn't show significant difference between two groups (p > 0.05 for all). Among the image quality scoring, overall image quality, motion artifact, showed significant difference between two groups with improved inadequate timing and centering after adaptation of immobilization device. Dose related data showed significantly decreased shot number, mean fluoroscopic time with decreased mean dose area product (DAP) value and effective dose after adaptation of immobilization device (p < 0.05 for all). CONCLUSION:Adaptation of immobilization device can improve overall image quality with decreased motion artifact and improved centering and timing with even shot number, mean fluoroscopic time with decreased mean DAP value and effective dose.
url https://doi.org/10.1371/journal.pone.0224063
work_keys_str_mv AT hyunhaecho effectofusingimmobilizationdeviceinfluoroscopicstudyinpediatricpatientfocusedonradiationdosereductioninvoidingcystourethrogram
AT somilee effectofusingimmobilizationdeviceinfluoroscopicstudyinpediatricpatientfocusedonradiationdosereductioninvoidingcystourethrogram
AT sunkyoungyou effectofusingimmobilizationdeviceinfluoroscopicstudyinpediatricpatientfocusedonradiationdosereductioninvoidingcystourethrogram
_version_ 1714818038467919872