Under the support from the Islamic Development Bank (IDB), Universitas Negeri Malang (UM) is going to build two-identical nine storey integrated classroom buildings. The buildings were designed to have green building certificate by proposing and fulfilling the requirements from the Green Building Co...

Full description

Bibliographic Details
Main Author: Hajji Apif M.
Format: Article
Language:English
Published: EDP Sciences 2019-01-01
Series:MATEC Web of Conferences
Online Access:https://www.matec-conferences.org/articles/matecconf/pdf/2019/25/matecconf_icancee2019_06023.pdf
id doaj-1db45c48078141d4b10dc4118c7d57b9
record_format Article
spelling doaj-1db45c48078141d4b10dc4118c7d57b92021-02-02T07:47:10ZengEDP SciencesMATEC Web of Conferences2261-236X2019-01-012760602310.1051/matecconf/201927606023matecconf_icancee2019_06023Toward energy efficiency measures for design of the IDB-funded integrated classroom building in Universitas Negeri MalangHajji Apif M.Under the support from the Islamic Development Bank (IDB), Universitas Negeri Malang (UM) is going to build two-identical nine storey integrated classroom buildings. The buildings were designed to have green building certificate by proposing and fulfilling the requirements from the Green Building Council Indonesia (GBCI) rating system. For design recognition (DR) phase, the system requires efforts and measures in energy efficiency. The paper analyses all design aspects and criteria included in the working drawings, technical specifications, and bill of quantities as provided in the buildings detailed-engineering-design (DED). The analysis covers the calculation of overall thermal transfer value (OTTV), artificial lighting, vertical transportation, and air conditioning system. By using energy modelling software, the OTTV for Building A and Building B, with 19,445.13 m2 of total floor area using VRF-AC system, are 31.78 W/m2 and 33.48 W/m2 respectively. The proposed annual energy use is 3510.90 MWh with the index of energy consumption is 180.55 kWh/m2 per-year. The results showed that by achieving 32.58% of energy efficiency, the DR of UM’s two classroom buildings is affordable to attain 11 points in the rating system.https://www.matec-conferences.org/articles/matecconf/pdf/2019/25/matecconf_icancee2019_06023.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Hajji Apif M.
spellingShingle Hajji Apif M.
Toward energy efficiency measures for design of the IDB-funded integrated classroom building in Universitas Negeri Malang
MATEC Web of Conferences
author_facet Hajji Apif M.
author_sort Hajji Apif M.
title Toward energy efficiency measures for design of the IDB-funded integrated classroom building in Universitas Negeri Malang
title_short Toward energy efficiency measures for design of the IDB-funded integrated classroom building in Universitas Negeri Malang
title_full Toward energy efficiency measures for design of the IDB-funded integrated classroom building in Universitas Negeri Malang
title_fullStr Toward energy efficiency measures for design of the IDB-funded integrated classroom building in Universitas Negeri Malang
title_full_unstemmed Toward energy efficiency measures for design of the IDB-funded integrated classroom building in Universitas Negeri Malang
title_sort toward energy efficiency measures for design of the idb-funded integrated classroom building in universitas negeri malang
publisher EDP Sciences
series MATEC Web of Conferences
issn 2261-236X
publishDate 2019-01-01
description Under the support from the Islamic Development Bank (IDB), Universitas Negeri Malang (UM) is going to build two-identical nine storey integrated classroom buildings. The buildings were designed to have green building certificate by proposing and fulfilling the requirements from the Green Building Council Indonesia (GBCI) rating system. For design recognition (DR) phase, the system requires efforts and measures in energy efficiency. The paper analyses all design aspects and criteria included in the working drawings, technical specifications, and bill of quantities as provided in the buildings detailed-engineering-design (DED). The analysis covers the calculation of overall thermal transfer value (OTTV), artificial lighting, vertical transportation, and air conditioning system. By using energy modelling software, the OTTV for Building A and Building B, with 19,445.13 m2 of total floor area using VRF-AC system, are 31.78 W/m2 and 33.48 W/m2 respectively. The proposed annual energy use is 3510.90 MWh with the index of energy consumption is 180.55 kWh/m2 per-year. The results showed that by achieving 32.58% of energy efficiency, the DR of UM’s two classroom buildings is affordable to attain 11 points in the rating system.
url https://www.matec-conferences.org/articles/matecconf/pdf/2019/25/matecconf_icancee2019_06023.pdf
work_keys_str_mv AT hajjiapifm towardenergyefficiencymeasuresfordesignoftheidbfundedintegratedclassroombuildinginuniversitasnegerimalang
_version_ 1724298737091608576