Efficiency of using cables on 6-110 kV with sticked polyethylene isolation

The expediency of using more expensive 6-10 kV cables with XLPE insulation was proved by us on the basis of the method of multi-purpose optimization, which took into account both the resulted costs for the construction and operation of cable lines, and the reliability of its operation, as well as th...

Full description

Bibliographic Details
Main Authors: Korotkevich Michail, Podgaisky Sergey, Golomuzdov Andrey
Format: Article
Language:English
Published: EDP Sciences 2017-01-01
Series:E3S Web of Conferences
Online Access:https://doi.org/10.1051/e3sconf/20172501010
id doaj-1d6f68bcc2324d308b0f5ce880835783
record_format Article
spelling doaj-1d6f68bcc2324d308b0f5ce8808357832021-04-02T11:23:58ZengEDP SciencesE3S Web of Conferences2267-12422017-01-01250101010.1051/e3sconf/20172501010e3sconf_rses2017_01010Efficiency of using cables on 6-110 kV with sticked polyethylene isolationKorotkevich MichailPodgaisky SergeyGolomuzdov AndreyThe expediency of using more expensive 6-10 kV cables with XLPE insulation was proved by us on the basis of the method of multi-purpose optimization, which took into account both the resulted costs for the construction and operation of cable lines, and the reliability of its operation, as well as the convenience of installation. Without compensation of capacitive currents, permissible difference in the height of the cable laying, the effect of cable lines on the environment.https://doi.org/10.1051/e3sconf/20172501010
collection DOAJ
language English
format Article
sources DOAJ
author Korotkevich Michail
Podgaisky Sergey
Golomuzdov Andrey
spellingShingle Korotkevich Michail
Podgaisky Sergey
Golomuzdov Andrey
Efficiency of using cables on 6-110 kV with sticked polyethylene isolation
E3S Web of Conferences
author_facet Korotkevich Michail
Podgaisky Sergey
Golomuzdov Andrey
author_sort Korotkevich Michail
title Efficiency of using cables on 6-110 kV with sticked polyethylene isolation
title_short Efficiency of using cables on 6-110 kV with sticked polyethylene isolation
title_full Efficiency of using cables on 6-110 kV with sticked polyethylene isolation
title_fullStr Efficiency of using cables on 6-110 kV with sticked polyethylene isolation
title_full_unstemmed Efficiency of using cables on 6-110 kV with sticked polyethylene isolation
title_sort efficiency of using cables on 6-110 kv with sticked polyethylene isolation
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2017-01-01
description The expediency of using more expensive 6-10 kV cables with XLPE insulation was proved by us on the basis of the method of multi-purpose optimization, which took into account both the resulted costs for the construction and operation of cable lines, and the reliability of its operation, as well as the convenience of installation. Without compensation of capacitive currents, permissible difference in the height of the cable laying, the effect of cable lines on the environment.
url https://doi.org/10.1051/e3sconf/20172501010
work_keys_str_mv AT korotkevichmichail efficiencyofusingcableson6110kvwithstickedpolyethyleneisolation
AT podgaiskysergey efficiencyofusingcableson6110kvwithstickedpolyethyleneisolation
AT golomuzdovandrey efficiencyofusingcableson6110kvwithstickedpolyethyleneisolation
_version_ 1724164883622133760