Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness
In developed countries like the UK, France, Italy and Germany, it is estimated that spending on maintenance and repair is practically the same as investment in new constructions. Therefore, this paper aims to study different ways of interfering in the corrosion kinetic using an accelerated corrosion...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Instituto Brasileiro do Concreto (IBRACON)
|
Series: | Revista IBRACON de Estruturas e Materiais |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952013000400004&lng=en&tlng=en |
id |
doaj-1d6ad439e0b749b5af634cb22517db03 |
---|---|
record_format |
Article |
spelling |
doaj-1d6ad439e0b749b5af634cb22517db032020-11-24T23:20:06ZengInstituto Brasileiro do Concreto (IBRACON)Revista IBRACON de Estruturas e Materiais1983-41956456158110.1590/S1983-41952013000400004S1983-41952013000400004Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thicknessE. Pereira0A. Resende1M. H. F. de Medeiros2L. C. Meneghetti3Universidade Estadual de Ponta GrossaUniversidade Estadual do Oeste do ParanáUniversidade Federal do ParanáUniversidade Estadual do Oeste do ParanáIn developed countries like the UK, France, Italy and Germany, it is estimated that spending on maintenance and repair is practically the same as investment in new constructions. Therefore, this paper aims to study different ways of interfering in the corrosion kinetic using an accelerated corrosion test - CAIM, that simulates the chloride attack. The three variables are: concrete cover thickness, use of silica fume and the water/binder ratio. It was found, by analysis of variance of the weight loss of the steel bars and chloride content in the concrete cover thickness, there is significant influence of the three variables. Also, the results indicate that the addition of silica fume is the path to improve the corrosion protection of low water/binder ratio concretes (like 0.4) and elevation of the concrete cover thickness is the most effective solution to increase protection of high water/binder ratio concrete (above 0.5).http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952013000400004&lng=en&tlng=encorrosionCAIMsilica fume, waterconcrete cover thickness |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
E. Pereira A. Resende M. H. F. de Medeiros L. C. Meneghetti |
spellingShingle |
E. Pereira A. Resende M. H. F. de Medeiros L. C. Meneghetti Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness Revista IBRACON de Estruturas e Materiais corrosion CAIM silica fume, water concrete cover thickness |
author_facet |
E. Pereira A. Resende M. H. F. de Medeiros L. C. Meneghetti |
author_sort |
E. Pereira |
title |
Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness |
title_short |
Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness |
title_full |
Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness |
title_fullStr |
Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness |
title_full_unstemmed |
Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness |
title_sort |
chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness |
publisher |
Instituto Brasileiro do Concreto (IBRACON) |
series |
Revista IBRACON de Estruturas e Materiais |
issn |
1983-4195 |
description |
In developed countries like the UK, France, Italy and Germany, it is estimated that spending on maintenance and repair is practically the same as investment in new constructions. Therefore, this paper aims to study different ways of interfering in the corrosion kinetic using an accelerated corrosion test - CAIM, that simulates the chloride attack. The three variables are: concrete cover thickness, use of silica fume and the water/binder ratio. It was found, by analysis of variance of the weight loss of the steel bars and chloride content in the concrete cover thickness, there is significant influence of the three variables. Also, the results indicate that the addition of silica fume is the path to improve the corrosion protection of low water/binder ratio concretes (like 0.4) and elevation of the concrete cover thickness is the most effective solution to increase protection of high water/binder ratio concrete (above 0.5). |
topic |
corrosion CAIM silica fume, water concrete cover thickness |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952013000400004&lng=en&tlng=en |
work_keys_str_mv |
AT epereira chlorideacceleratedtestinfluenceofsilicafumewaterbinderratioandconcretecoverthickness AT aresende chlorideacceleratedtestinfluenceofsilicafumewaterbinderratioandconcretecoverthickness AT mhfdemedeiros chlorideacceleratedtestinfluenceofsilicafumewaterbinderratioandconcretecoverthickness AT lcmeneghetti chlorideacceleratedtestinfluenceofsilicafumewaterbinderratioandconcretecoverthickness |
_version_ |
1725576091278508032 |