Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness

In developed countries like the UK, France, Italy and Germany, it is estimated that spending on maintenance and repair is practically the same as investment in new constructions. Therefore, this paper aims to study different ways of interfering in the corrosion kinetic using an accelerated corrosion...

Full description

Bibliographic Details
Main Authors: E. Pereira, A. Resende, M. H. F. de Medeiros, L. C. Meneghetti
Format: Article
Language:English
Published: Instituto Brasileiro do Concreto (IBRACON)
Series:Revista IBRACON de Estruturas e Materiais
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952013000400004&lng=en&tlng=en
id doaj-1d6ad439e0b749b5af634cb22517db03
record_format Article
spelling doaj-1d6ad439e0b749b5af634cb22517db032020-11-24T23:20:06ZengInstituto Brasileiro do Concreto (IBRACON)Revista IBRACON de Estruturas e Materiais1983-41956456158110.1590/S1983-41952013000400004S1983-41952013000400004Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thicknessE. Pereira0A. Resende1M. H. F. de Medeiros2L. C. Meneghetti3Universidade Estadual de Ponta GrossaUniversidade Estadual do Oeste do ParanáUniversidade Federal do ParanáUniversidade Estadual do Oeste do ParanáIn developed countries like the UK, France, Italy and Germany, it is estimated that spending on maintenance and repair is practically the same as investment in new constructions. Therefore, this paper aims to study different ways of interfering in the corrosion kinetic using an accelerated corrosion test - CAIM, that simulates the chloride attack. The three variables are: concrete cover thickness, use of silica fume and the water/binder ratio. It was found, by analysis of variance of the weight loss of the steel bars and chloride content in the concrete cover thickness, there is significant influence of the three variables. Also, the results indicate that the addition of silica fume is the path to improve the corrosion protection of low water/binder ratio concretes (like 0.4) and elevation of the concrete cover thickness is the most effective solution to increase protection of high water/binder ratio concrete (above 0.5).http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952013000400004&lng=en&tlng=encorrosionCAIMsilica fume, waterconcrete cover thickness
collection DOAJ
language English
format Article
sources DOAJ
author E. Pereira
A. Resende
M. H. F. de Medeiros
L. C. Meneghetti
spellingShingle E. Pereira
A. Resende
M. H. F. de Medeiros
L. C. Meneghetti
Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness
Revista IBRACON de Estruturas e Materiais
corrosion
CAIM
silica fume, water
concrete cover thickness
author_facet E. Pereira
A. Resende
M. H. F. de Medeiros
L. C. Meneghetti
author_sort E. Pereira
title Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness
title_short Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness
title_full Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness
title_fullStr Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness
title_full_unstemmed Chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness
title_sort chloride accelerated test: influence of silica fume, water/binder ratio and concrete cover thickness
publisher Instituto Brasileiro do Concreto (IBRACON)
series Revista IBRACON de Estruturas e Materiais
issn 1983-4195
description In developed countries like the UK, France, Italy and Germany, it is estimated that spending on maintenance and repair is practically the same as investment in new constructions. Therefore, this paper aims to study different ways of interfering in the corrosion kinetic using an accelerated corrosion test - CAIM, that simulates the chloride attack. The three variables are: concrete cover thickness, use of silica fume and the water/binder ratio. It was found, by analysis of variance of the weight loss of the steel bars and chloride content in the concrete cover thickness, there is significant influence of the three variables. Also, the results indicate that the addition of silica fume is the path to improve the corrosion protection of low water/binder ratio concretes (like 0.4) and elevation of the concrete cover thickness is the most effective solution to increase protection of high water/binder ratio concrete (above 0.5).
topic corrosion
CAIM
silica fume, water
concrete cover thickness
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952013000400004&lng=en&tlng=en
work_keys_str_mv AT epereira chlorideacceleratedtestinfluenceofsilicafumewaterbinderratioandconcretecoverthickness
AT aresende chlorideacceleratedtestinfluenceofsilicafumewaterbinderratioandconcretecoverthickness
AT mhfdemedeiros chlorideacceleratedtestinfluenceofsilicafumewaterbinderratioandconcretecoverthickness
AT lcmeneghetti chlorideacceleratedtestinfluenceofsilicafumewaterbinderratioandconcretecoverthickness
_version_ 1725576091278508032