Technical Measures to Mitigate Load Fluctuation for Large-Scale Customers to Improve Power System Energy Efficiency

Industrial equipment such as electric arc furnaces and steel mills are often associated with rapid and high load disturbances, so their power systems require additional control equipment to limit the frequency. However, proper ancillary service fees are not paid in these cases with extreme and varia...

Full description

Bibliographic Details
Main Authors: Yongsik Lee, Hyunchul Lee, Jaehyeon Gim, Inyong Seo, Guenjoon Lee
Format: Article
Language:English
Published: MDPI AG 2020-09-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/13/18/4812
id doaj-1d2a0221769947879b06b0e22109dec9
record_format Article
spelling doaj-1d2a0221769947879b06b0e22109dec92020-11-25T03:06:47ZengMDPI AGEnergies1996-10732020-09-01134812481210.3390/en13184812Technical Measures to Mitigate Load Fluctuation for Large-Scale Customers to Improve Power System Energy EfficiencyYongsik Lee0Hyunchul Lee1Jaehyeon Gim2Inyong Seo3Guenjoon Lee4Director of Research, SRENG Corp., Suncheon 58023, KoreaDepartment of Electrical Engineering, Woosuk University, Wanju 55338, KoreaDepartment of Electrical Engineering, Sunchon National University, Suncheon 57922, KoreaCollege of Information and Computer Engineering, Sungkyunkwan University, Suwon 16419, KoreaDepartment of Electric Energy Systems, Chungbuk Provincial University, Okcheon 29046, KoreaIndustrial equipment such as electric arc furnaces and steel mills are often associated with rapid and high load disturbances, so their power systems require additional control equipment to limit the frequency. However, proper ancillary service fees are not paid in these cases with extreme and variable load demands. The frequency regulation reserve equipment adds to power generation costs. Therefore, variable power generation loads lead to increases in the cost of energy production. We propose a load frequency control method that is applied on the customer end instead of the power supply end to reduce the operating reserve required to improve the energy efficiency of the power system. We analyzed the load fluctuation of steel mill customers using real data sampled at two-second intervals from the energy management system in Korea. We developed an automatic generation control program to simulate the power system’s frequency characteristics. We also propose compensation techniques for mitigation of the system’s frequency deviation at the customer end based on an energy storage system, pump storage hydro generator, customer generator, and plant process adjustment. To recover the frequency deviation, we calculated the compensation facility capacity and analyzed static characteristics, and we proved the feasibility via simulations.https://www.mdpi.com/1996-1073/13/18/4812load fluctuationoperating reserveload frequency controlautomatic generation control
collection DOAJ
language English
format Article
sources DOAJ
author Yongsik Lee
Hyunchul Lee
Jaehyeon Gim
Inyong Seo
Guenjoon Lee
spellingShingle Yongsik Lee
Hyunchul Lee
Jaehyeon Gim
Inyong Seo
Guenjoon Lee
Technical Measures to Mitigate Load Fluctuation for Large-Scale Customers to Improve Power System Energy Efficiency
Energies
load fluctuation
operating reserve
load frequency control
automatic generation control
author_facet Yongsik Lee
Hyunchul Lee
Jaehyeon Gim
Inyong Seo
Guenjoon Lee
author_sort Yongsik Lee
title Technical Measures to Mitigate Load Fluctuation for Large-Scale Customers to Improve Power System Energy Efficiency
title_short Technical Measures to Mitigate Load Fluctuation for Large-Scale Customers to Improve Power System Energy Efficiency
title_full Technical Measures to Mitigate Load Fluctuation for Large-Scale Customers to Improve Power System Energy Efficiency
title_fullStr Technical Measures to Mitigate Load Fluctuation for Large-Scale Customers to Improve Power System Energy Efficiency
title_full_unstemmed Technical Measures to Mitigate Load Fluctuation for Large-Scale Customers to Improve Power System Energy Efficiency
title_sort technical measures to mitigate load fluctuation for large-scale customers to improve power system energy efficiency
publisher MDPI AG
series Energies
issn 1996-1073
publishDate 2020-09-01
description Industrial equipment such as electric arc furnaces and steel mills are often associated with rapid and high load disturbances, so their power systems require additional control equipment to limit the frequency. However, proper ancillary service fees are not paid in these cases with extreme and variable load demands. The frequency regulation reserve equipment adds to power generation costs. Therefore, variable power generation loads lead to increases in the cost of energy production. We propose a load frequency control method that is applied on the customer end instead of the power supply end to reduce the operating reserve required to improve the energy efficiency of the power system. We analyzed the load fluctuation of steel mill customers using real data sampled at two-second intervals from the energy management system in Korea. We developed an automatic generation control program to simulate the power system’s frequency characteristics. We also propose compensation techniques for mitigation of the system’s frequency deviation at the customer end based on an energy storage system, pump storage hydro generator, customer generator, and plant process adjustment. To recover the frequency deviation, we calculated the compensation facility capacity and analyzed static characteristics, and we proved the feasibility via simulations.
topic load fluctuation
operating reserve
load frequency control
automatic generation control
url https://www.mdpi.com/1996-1073/13/18/4812
work_keys_str_mv AT yongsiklee technicalmeasurestomitigateloadfluctuationforlargescalecustomerstoimprovepowersystemenergyefficiency
AT hyunchullee technicalmeasurestomitigateloadfluctuationforlargescalecustomerstoimprovepowersystemenergyefficiency
AT jaehyeongim technicalmeasurestomitigateloadfluctuationforlargescalecustomerstoimprovepowersystemenergyefficiency
AT inyongseo technicalmeasurestomitigateloadfluctuationforlargescalecustomerstoimprovepowersystemenergyefficiency
AT guenjoonlee technicalmeasurestomitigateloadfluctuationforlargescalecustomerstoimprovepowersystemenergyefficiency
_version_ 1724672388298178560