Portable selfcentred device with calibrated rollers
The critical analysis of the self-centering devices for inner cylindrical surfaces highlights a number of advantages and disadvantages of these solutions. The key benefit is the precision but the most important disadvantage it is that doesn’t covers a sufficiently range of values for the inner diame...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2017-01-01
|
Series: | MATEC Web of Conferences |
Online Access: | https://doi.org/10.1051/matecconf/201711201001 |
id |
doaj-1d0f89abb4f845e6abec3972631f1c82 |
---|---|
record_format |
Article |
spelling |
doaj-1d0f89abb4f845e6abec3972631f1c822021-02-02T04:18:09ZengEDP SciencesMATEC Web of Conferences2261-236X2017-01-011120100110.1051/matecconf/201711201001matecconf_imane2017_01001Portable selfcentred device with calibrated rollersMunteanu AdrianaCioata FlorentinPaduraru EmilianThe critical analysis of the self-centering devices for inner cylindrical surfaces highlights a number of advantages and disadvantages of these solutions. The key benefit is the precision but the most important disadvantage it is that doesn’t covers a sufficiently range of values for the inner diameters and are very complex. In the present paper a solution of centering mechanism with calibrated rollers that eliminates the disadvantages mentioned above, with a medium complexity but ensuring a sufficient range of values for measured surfaces is proposed. The method used to obtain the specified range of values is graphic method.https://doi.org/10.1051/matecconf/201711201001 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Munteanu Adriana Cioata Florentin Paduraru Emilian |
spellingShingle |
Munteanu Adriana Cioata Florentin Paduraru Emilian Portable selfcentred device with calibrated rollers MATEC Web of Conferences |
author_facet |
Munteanu Adriana Cioata Florentin Paduraru Emilian |
author_sort |
Munteanu Adriana |
title |
Portable selfcentred device with calibrated rollers |
title_short |
Portable selfcentred device with calibrated rollers |
title_full |
Portable selfcentred device with calibrated rollers |
title_fullStr |
Portable selfcentred device with calibrated rollers |
title_full_unstemmed |
Portable selfcentred device with calibrated rollers |
title_sort |
portable selfcentred device with calibrated rollers |
publisher |
EDP Sciences |
series |
MATEC Web of Conferences |
issn |
2261-236X |
publishDate |
2017-01-01 |
description |
The critical analysis of the self-centering devices for inner cylindrical surfaces highlights a number of advantages and disadvantages of these solutions. The key benefit is the precision but the most important disadvantage it is that doesn’t covers a sufficiently range of values for the inner diameters and are very complex. In the present paper a solution of centering mechanism with calibrated rollers that eliminates the disadvantages mentioned above, with a medium complexity but ensuring a sufficient range of values for measured surfaces is proposed. The method used to obtain the specified range of values is graphic method. |
url |
https://doi.org/10.1051/matecconf/201711201001 |
work_keys_str_mv |
AT munteanuadriana portableselfcentreddevicewithcalibratedrollers AT cioataflorentin portableselfcentreddevicewithcalibratedrollers AT paduraruemilian portableselfcentreddevicewithcalibratedrollers |
_version_ |
1724306053533794304 |