Fabrication of high-performance PVA/PAN composite pervaporation membranes crosslinked by PMDA for wastewater desalination
Abstract The pyromellitic dianhydride (PMDA) crosslinked poly(vinyl alcohol) (PVA) was coated on top of the PAN ultrafiltration membrane to form a PVA/PAN composite PV membranes for wastewater desalination. The composite membranes have high application value in industrial wastewater treatment. By va...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
SpringerOpen
2018-01-01
|
Series: | Petroleum Science |
Subjects: | |
Online Access: | http://link.springer.com/article/10.1007/s12182-017-0204-z |
id |
doaj-1cd109ccda994bc9b98dd5c5ece179be |
---|---|
record_format |
Article |
spelling |
doaj-1cd109ccda994bc9b98dd5c5ece179be2020-11-25T00:41:56ZengSpringerOpenPetroleum Science1672-51071995-82262018-01-0115114615610.1007/s12182-017-0204-zFabrication of high-performance PVA/PAN composite pervaporation membranes crosslinked by PMDA for wastewater desalinationRui Zhang0Xiaoying Xu1Bing Cao2Pei Li3College of Materials Science and Engineering, Beijing University of Chemical TechnologyCollege of Materials Science and Engineering, Beijing University of Chemical TechnologyCollege of Materials Science and Engineering, Beijing University of Chemical TechnologyCollege of Materials Science and Engineering, Beijing University of Chemical TechnologyAbstract The pyromellitic dianhydride (PMDA) crosslinked poly(vinyl alcohol) (PVA) was coated on top of the PAN ultrafiltration membrane to form a PVA/PAN composite PV membranes for wastewater desalination. The composite membranes have high application value in industrial wastewater treatment. By varying the membrane fabrication parameters including the weight percent (wt%) of the PMDA, the crosslink temperature and duration, membrane with the best desalination performance was obtained. The composite membrane with a 2-μm-thick PVA selective layer containing 20 wt% of PMDA and being crosslinked at 100 °C for 2 h showed the highest NaCl rejection of 99.98% with a water flux of 32.26 L/(m2 h) at 70 °C using the 35,000 ppm NaCl aqueous solution as feed. FTIR spectroscopy, wide-angle X-ray diffraction, thermogravimetric analysis and scanning electron microscope have been used to characterize the structures and properties of both the crosslinked PVA dense films and PVA/PAN composite membranes. The effects of the concentrations of PMDA, the crosslinking time and temperature to the membrane water contact angle, swelling degree, salt rejection and water flux were systematically studied.http://link.springer.com/article/10.1007/s12182-017-0204-zPervaporationDesalinationCrosslinked PVAComposite membranesWastewater treatment |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Rui Zhang Xiaoying Xu Bing Cao Pei Li |
spellingShingle |
Rui Zhang Xiaoying Xu Bing Cao Pei Li Fabrication of high-performance PVA/PAN composite pervaporation membranes crosslinked by PMDA for wastewater desalination Petroleum Science Pervaporation Desalination Crosslinked PVA Composite membranes Wastewater treatment |
author_facet |
Rui Zhang Xiaoying Xu Bing Cao Pei Li |
author_sort |
Rui Zhang |
title |
Fabrication of high-performance PVA/PAN composite pervaporation membranes crosslinked by PMDA for wastewater desalination |
title_short |
Fabrication of high-performance PVA/PAN composite pervaporation membranes crosslinked by PMDA for wastewater desalination |
title_full |
Fabrication of high-performance PVA/PAN composite pervaporation membranes crosslinked by PMDA for wastewater desalination |
title_fullStr |
Fabrication of high-performance PVA/PAN composite pervaporation membranes crosslinked by PMDA for wastewater desalination |
title_full_unstemmed |
Fabrication of high-performance PVA/PAN composite pervaporation membranes crosslinked by PMDA for wastewater desalination |
title_sort |
fabrication of high-performance pva/pan composite pervaporation membranes crosslinked by pmda for wastewater desalination |
publisher |
SpringerOpen |
series |
Petroleum Science |
issn |
1672-5107 1995-8226 |
publishDate |
2018-01-01 |
description |
Abstract The pyromellitic dianhydride (PMDA) crosslinked poly(vinyl alcohol) (PVA) was coated on top of the PAN ultrafiltration membrane to form a PVA/PAN composite PV membranes for wastewater desalination. The composite membranes have high application value in industrial wastewater treatment. By varying the membrane fabrication parameters including the weight percent (wt%) of the PMDA, the crosslink temperature and duration, membrane with the best desalination performance was obtained. The composite membrane with a 2-μm-thick PVA selective layer containing 20 wt% of PMDA and being crosslinked at 100 °C for 2 h showed the highest NaCl rejection of 99.98% with a water flux of 32.26 L/(m2 h) at 70 °C using the 35,000 ppm NaCl aqueous solution as feed. FTIR spectroscopy, wide-angle X-ray diffraction, thermogravimetric analysis and scanning electron microscope have been used to characterize the structures and properties of both the crosslinked PVA dense films and PVA/PAN composite membranes. The effects of the concentrations of PMDA, the crosslinking time and temperature to the membrane water contact angle, swelling degree, salt rejection and water flux were systematically studied. |
topic |
Pervaporation Desalination Crosslinked PVA Composite membranes Wastewater treatment |
url |
http://link.springer.com/article/10.1007/s12182-017-0204-z |
work_keys_str_mv |
AT ruizhang fabricationofhighperformancepvapancompositepervaporationmembranescrosslinkedbypmdaforwastewaterdesalination AT xiaoyingxu fabricationofhighperformancepvapancompositepervaporationmembranescrosslinkedbypmdaforwastewaterdesalination AT bingcao fabricationofhighperformancepvapancompositepervaporationmembranescrosslinkedbypmdaforwastewaterdesalination AT peili fabricationofhighperformancepvapancompositepervaporationmembranescrosslinkedbypmdaforwastewaterdesalination |
_version_ |
1725284829061185536 |