Improving the lifetime of an electro-compressor for autoclave with optimized buffer tank
In order to increase the research capabilities in the field of lowweight intelligent materials and high structural performance, and also to increase energy efficiency, a study was conducted on improving the operating time of a hot air autoclave compressor with a buffer tank. The booster screw electr...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2021-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/62/e3sconf_tererd2021_01004.pdf |
id |
doaj-1c625423788b4e75992f13665e2e2ac1 |
---|---|
record_format |
Article |
spelling |
doaj-1c625423788b4e75992f13665e2e2ac12021-07-13T14:56:13ZengEDP SciencesE3S Web of Conferences2267-12422021-01-012860100410.1051/e3sconf/202128601004e3sconf_tererd2021_01004Improving the lifetime of an electro-compressor for autoclave with optimized buffer tankVlăducă Iulian0Borzea Claudia Irina1Petre Carmen Gheorghiţa2Hriţcu Romeo Dorin3Maier Raluca Lucia4Ringheanu Vicențiu Liviu5Stanciuc Ramona Manuela6Romanian Research and Development Institute for Gas Turbines COMOTIRomanian Research and Development Institute for Gas Turbines COMOTIRomanian Research and Development Institute for Gas Turbines COMOTIRomanian Research and Development Institute for Gas Turbines COMOTIRomanian Research and Development Institute for Gas Turbines COMOTIRomanian Research and Development Institute for Gas Turbines COMOTIRomanian Research and Development Institute for Gas Turbines COMOTIIn order to increase the research capabilities in the field of lowweight intelligent materials and high structural performance, and also to increase energy efficiency, a study was conducted on improving the operating time of a hot air autoclave compressor with a buffer tank. The booster screw electro-compressor of 200 kW is designed to compress technological air to the installation’s necessary parameters at 1 ppm air purity, and the pressurized buffer tank is designed to reduce the number of start-ups of the compressor unit and its motor, in order to increase its lifespan. The pressure can vary in the designed buffer tank from 7 to 26 bar (abs). The autoclave parameters record thermodynamic modifications as it heats up to 400 °C at the working pressure. Cool air is required during the cooling process. The air mass exchanged during operation for cooling down to atmospheric temperature was calculated. The data obtained was used for validating an optimally designed buffer tank within the required operational parameters limits, set and acquired by the custom-made automation system.https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/62/e3sconf_tererd2021_01004.pdf |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Vlăducă Iulian Borzea Claudia Irina Petre Carmen Gheorghiţa Hriţcu Romeo Dorin Maier Raluca Lucia Ringheanu Vicențiu Liviu Stanciuc Ramona Manuela |
spellingShingle |
Vlăducă Iulian Borzea Claudia Irina Petre Carmen Gheorghiţa Hriţcu Romeo Dorin Maier Raluca Lucia Ringheanu Vicențiu Liviu Stanciuc Ramona Manuela Improving the lifetime of an electro-compressor for autoclave with optimized buffer tank E3S Web of Conferences |
author_facet |
Vlăducă Iulian Borzea Claudia Irina Petre Carmen Gheorghiţa Hriţcu Romeo Dorin Maier Raluca Lucia Ringheanu Vicențiu Liviu Stanciuc Ramona Manuela |
author_sort |
Vlăducă Iulian |
title |
Improving the lifetime of an electro-compressor for autoclave with optimized buffer tank |
title_short |
Improving the lifetime of an electro-compressor for autoclave with optimized buffer tank |
title_full |
Improving the lifetime of an electro-compressor for autoclave with optimized buffer tank |
title_fullStr |
Improving the lifetime of an electro-compressor for autoclave with optimized buffer tank |
title_full_unstemmed |
Improving the lifetime of an electro-compressor for autoclave with optimized buffer tank |
title_sort |
improving the lifetime of an electro-compressor for autoclave with optimized buffer tank |
publisher |
EDP Sciences |
series |
E3S Web of Conferences |
issn |
2267-1242 |
publishDate |
2021-01-01 |
description |
In order to increase the research capabilities in the field of lowweight intelligent materials and high structural performance, and also to increase energy efficiency, a study was conducted on improving the operating time of a hot air autoclave compressor with a buffer tank. The booster screw electro-compressor of 200 kW is designed to compress technological air to the installation’s necessary parameters at 1 ppm air purity, and the pressurized buffer tank is designed to reduce the number of start-ups of the compressor unit and its motor, in order to increase its lifespan. The pressure can vary in the designed buffer tank from 7 to 26 bar (abs). The autoclave parameters record thermodynamic modifications as it heats up to 400 °C at the working pressure. Cool air is required during the cooling process. The air mass exchanged during operation for cooling down to atmospheric temperature was calculated. The data obtained was used for validating an optimally designed buffer tank within the required operational parameters limits, set and acquired by the custom-made automation system. |
url |
https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/62/e3sconf_tererd2021_01004.pdf |
work_keys_str_mv |
AT vladucaiulian improvingthelifetimeofanelectrocompressorforautoclavewithoptimizedbuffertank AT borzeaclaudiairina improvingthelifetimeofanelectrocompressorforautoclavewithoptimizedbuffertank AT petrecarmengheorghita improvingthelifetimeofanelectrocompressorforautoclavewithoptimizedbuffertank AT hritcuromeodorin improvingthelifetimeofanelectrocompressorforautoclavewithoptimizedbuffertank AT maierralucalucia improvingthelifetimeofanelectrocompressorforautoclavewithoptimizedbuffertank AT ringheanuvicentiuliviu improvingthelifetimeofanelectrocompressorforautoclavewithoptimizedbuffertank AT stanciucramonamanuela improvingthelifetimeofanelectrocompressorforautoclavewithoptimizedbuffertank |
_version_ |
1721305245878845440 |