Análisis experimental del desgaste entre UHMWPE y acero inoxidable 316l empleados en la manufactura de prótesis coxofemorales
Título en inglés: Experimental wear analysis of UHMWPE and stainless 316l used in the manufacturing of coxofemoral prosthesis. Resumen La causa más común de falla en prótesis coxofemorales es el aflojamiento entre los componentes que conforman el sistema, de manera específica la copa acetabular y...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | Spanish |
Published: |
Universidad Nacional de Colombia
2010-10-01
|
Series: | Revista Colombiana de Biotecnología |
Subjects: | |
Online Access: | http://www.revistas.unal.edu.co/index.php/biotecnologia/article/view/18536 |
id |
doaj-1c54c14c32464cb694057f218309a036 |
---|---|
record_format |
Article |
collection |
DOAJ |
language |
Spanish |
format |
Article |
sources |
DOAJ |
author |
Ricardo Gustavo Rodríguez Cañizo Leonardo Azael García García Manuel Vite Torres Emmanuel Alejandro Merchán Cruz Juan Manuel Sandoval Pineda |
spellingShingle |
Ricardo Gustavo Rodríguez Cañizo Leonardo Azael García García Manuel Vite Torres Emmanuel Alejandro Merchán Cruz Juan Manuel Sandoval Pineda Análisis experimental del desgaste entre UHMWPE y acero inoxidable 316l empleados en la manufactura de prótesis coxofemorales Revista Colombiana de Biotecnología pruebas pin-on-disk copa acetabular cabeza femoral suero bovino tasa anual de desgaste coeficientes de fricción Test Pin-on-Disk acetabular cup femoral head bovine serum anual wearing |
author_facet |
Ricardo Gustavo Rodríguez Cañizo Leonardo Azael García García Manuel Vite Torres Emmanuel Alejandro Merchán Cruz Juan Manuel Sandoval Pineda |
author_sort |
Ricardo Gustavo Rodríguez Cañizo |
title |
Análisis experimental del desgaste entre UHMWPE y acero inoxidable 316l empleados en la manufactura de prótesis coxofemorales |
title_short |
Análisis experimental del desgaste entre UHMWPE y acero inoxidable 316l empleados en la manufactura de prótesis coxofemorales |
title_full |
Análisis experimental del desgaste entre UHMWPE y acero inoxidable 316l empleados en la manufactura de prótesis coxofemorales |
title_fullStr |
Análisis experimental del desgaste entre UHMWPE y acero inoxidable 316l empleados en la manufactura de prótesis coxofemorales |
title_full_unstemmed |
Análisis experimental del desgaste entre UHMWPE y acero inoxidable 316l empleados en la manufactura de prótesis coxofemorales |
title_sort |
análisis experimental del desgaste entre uhmwpe y acero inoxidable 316l empleados en la manufactura de prótesis coxofemorales |
publisher |
Universidad Nacional de Colombia |
series |
Revista Colombiana de Biotecnología |
issn |
0123-3475 1909-8758 |
publishDate |
2010-10-01 |
description |
Título en inglés: Experimental wear analysis of UHMWPE and stainless 316l used in the manufacturing of coxofemoral prosthesis.
Resumen
La causa más común de falla en prótesis coxofemorales es el aflojamiento entre los componentes que conforman el sistema, de manera específica la copa acetabular y la cabeza femoral. En esta investigación se presenta un análisis tribológico del desgaste en los componentes mencionados, ya que cuando las superficies en contacto se desgastan, la funcionalidad mecánica del sistema se compromete, debido al cambio de geometría de los mismos, dando como resultado un juego mecánico entre la copa y la cabeza. Los materiales considerados en este estudio son el polietileno de ultra elevado peso molecular (UHMWPE, por sus siglas en inglés) para la copa acetabular, y acero inoxidable 316L para la cabeza femoral. Esta combinación de materiales representa hoy en día la recomendación más usual por parte de los cirujanos para pacientes de la tercera edad. La tasa anual de desgaste se determinó de manera experimental y se cuantificó la cantidad de material desprendido durante el contacto. Se establecieron las condiciones de carga de forma analítica, considerando las que actúan sobre la cabeza femoral a lo largo del área de desgaste durante la marcha humana. Posteriormente, se realizó el análisis experimental de desgaste utilizando una máquina tribológica de configuración perno-sobre-disco (pin-on-disk), diseñada de manera específica para este estudio. Las pruebas para determinar la pérdida volumétrica de los componentes se realizaron bajo tres condiciones de operación: en seco, lubricada con agua destilada y lubricada con suero bovino. El marco experimental considerado consistió en pernos de UHMWPE sobre discos de acero inoxidable 316L simulando el desgaste equivalente a diez años de uso de la prótesis. Finalmente, de los resultados obtenidos se puede establecer que el desgaste y la cantidad de partículas desprendidas disminuyen considerablemente cuando se utiliza suero bovino como lubricante para replicar las condiciones reales de operación del sistema por tener propiedades muy semejantes a las del fluido sinovial presente en la articulación de la cadera. El caso seco representó el peor escenario en donde se produce mayor daño.
Palabras clave: pruebas pin-on-disk, copa acetabular, cabeza femoral, suero bovino, tasa anual de desgaste, coeficientes de fricción.
Abstract
The most common cause of failure in coxofemoral prostheses is the loosening between the components of the system, namely the acetabular cup and the femoral head. In this work a tribologic analysis of wear suffered in the components is presented, due to when the surfaces in contact are worn, the mechanical function of the system is compromised as the wearing implies a change in the geometry of the components, thus in their dimensions, resulting on a looseness between the cup and the head. The materials considered in this study are Ultra High Molecular Weight Polyethylene (UHMWPE) for the cup and 316L Stainless Steel for the femoral head, which represent the surgeons choice for elderly patients. The annual wearing rate between these components was experimentally determined, as well as the amount of debris produced during contact. Firstly, the loading conditions were determined analytically considering those acting on the femoral head taking into consideration the wearing area during human walk. Secondly, the experimental analysis consisted in wearing tests using a tribology pin-on-disk machine, specifically built for this study. The tests to determine the volumetric loss of the components were performed under three different operational conditions: dry, lubricated with bovine serum and lubricated with destilated water. The experimental set up consisted on UHMWPE pins and 316L Stainless steel discs simulating the equivalent wear of ten years of usage of the prostheses. Lastly, the obtained results proved that using the bovine serum as lubricant the wear and debris of the components was significantly reduced when compared with other cases, being the dry scenario where more damage was produced. It is important to point out that the bovine serum was chosen to simulate the synovial fluid in which the system is embedded.
Key words: Test Pin-on-Disk, acetabular cup, femoral head, bovine serum, anual wearing. |
topic |
pruebas pin-on-disk copa acetabular cabeza femoral suero bovino tasa anual de desgaste coeficientes de fricción Test Pin-on-Disk acetabular cup femoral head bovine serum anual wearing |
url |
http://www.revistas.unal.edu.co/index.php/biotecnologia/article/view/18536 |
work_keys_str_mv |
AT ricardogustavorodriguezcanizo analisisexperimentaldeldesgasteentreuhmwpeyaceroinoxidable316lempleadosenlamanufacturadeprotesiscoxofemorales AT leonardoazaelgarciagarcia analisisexperimentaldeldesgasteentreuhmwpeyaceroinoxidable316lempleadosenlamanufacturadeprotesiscoxofemorales AT manuelvitetorres analisisexperimentaldeldesgasteentreuhmwpeyaceroinoxidable316lempleadosenlamanufacturadeprotesiscoxofemorales AT emmanuelalejandromerchancruz analisisexperimentaldeldesgasteentreuhmwpeyaceroinoxidable316lempleadosenlamanufacturadeprotesiscoxofemorales AT juanmanuelsandovalpineda analisisexperimentaldeldesgasteentreuhmwpeyaceroinoxidable316lempleadosenlamanufacturadeprotesiscoxofemorales |
_version_ |
1725991262338678784 |
spelling |
doaj-1c54c14c32464cb694057f218309a0362020-11-24T21:23:47ZspaUniversidad Nacional de ColombiaRevista Colombiana de Biotecnología0123-34751909-87582010-10-01122678516883Análisis experimental del desgaste entre UHMWPE y acero inoxidable 316l empleados en la manufactura de prótesis coxofemoralesRicardo Gustavo Rodríguez Cañizo0Leonardo Azael García García1Manuel Vite Torres2Emmanuel Alejandro Merchán Cruz3Juan Manuel Sandoval Pineda4DocenteInvestigadorInvestigadorInvestigadorInvestigadorTítulo en inglés: Experimental wear analysis of UHMWPE and stainless 316l used in the manufacturing of coxofemoral prosthesis. Resumen La causa más común de falla en prótesis coxofemorales es el aflojamiento entre los componentes que conforman el sistema, de manera específica la copa acetabular y la cabeza femoral. En esta investigación se presenta un análisis tribológico del desgaste en los componentes mencionados, ya que cuando las superficies en contacto se desgastan, la funcionalidad mecánica del sistema se compromete, debido al cambio de geometría de los mismos, dando como resultado un juego mecánico entre la copa y la cabeza. Los materiales considerados en este estudio son el polietileno de ultra elevado peso molecular (UHMWPE, por sus siglas en inglés) para la copa acetabular, y acero inoxidable 316L para la cabeza femoral. Esta combinación de materiales representa hoy en día la recomendación más usual por parte de los cirujanos para pacientes de la tercera edad. La tasa anual de desgaste se determinó de manera experimental y se cuantificó la cantidad de material desprendido durante el contacto. Se establecieron las condiciones de carga de forma analítica, considerando las que actúan sobre la cabeza femoral a lo largo del área de desgaste durante la marcha humana. Posteriormente, se realizó el análisis experimental de desgaste utilizando una máquina tribológica de configuración perno-sobre-disco (pin-on-disk), diseñada de manera específica para este estudio. Las pruebas para determinar la pérdida volumétrica de los componentes se realizaron bajo tres condiciones de operación: en seco, lubricada con agua destilada y lubricada con suero bovino. El marco experimental considerado consistió en pernos de UHMWPE sobre discos de acero inoxidable 316L simulando el desgaste equivalente a diez años de uso de la prótesis. Finalmente, de los resultados obtenidos se puede establecer que el desgaste y la cantidad de partículas desprendidas disminuyen considerablemente cuando se utiliza suero bovino como lubricante para replicar las condiciones reales de operación del sistema por tener propiedades muy semejantes a las del fluido sinovial presente en la articulación de la cadera. El caso seco representó el peor escenario en donde se produce mayor daño. Palabras clave: pruebas pin-on-disk, copa acetabular, cabeza femoral, suero bovino, tasa anual de desgaste, coeficientes de fricción. Abstract The most common cause of failure in coxofemoral prostheses is the loosening between the components of the system, namely the acetabular cup and the femoral head. In this work a tribologic analysis of wear suffered in the components is presented, due to when the surfaces in contact are worn, the mechanical function of the system is compromised as the wearing implies a change in the geometry of the components, thus in their dimensions, resulting on a looseness between the cup and the head. The materials considered in this study are Ultra High Molecular Weight Polyethylene (UHMWPE) for the cup and 316L Stainless Steel for the femoral head, which represent the surgeons choice for elderly patients. The annual wearing rate between these components was experimentally determined, as well as the amount of debris produced during contact. Firstly, the loading conditions were determined analytically considering those acting on the femoral head taking into consideration the wearing area during human walk. Secondly, the experimental analysis consisted in wearing tests using a tribology pin-on-disk machine, specifically built for this study. The tests to determine the volumetric loss of the components were performed under three different operational conditions: dry, lubricated with bovine serum and lubricated with destilated water. The experimental set up consisted on UHMWPE pins and 316L Stainless steel discs simulating the equivalent wear of ten years of usage of the prostheses. Lastly, the obtained results proved that using the bovine serum as lubricant the wear and debris of the components was significantly reduced when compared with other cases, being the dry scenario where more damage was produced. It is important to point out that the bovine serum was chosen to simulate the synovial fluid in which the system is embedded. Key words: Test Pin-on-Disk, acetabular cup, femoral head, bovine serum, anual wearing.http://www.revistas.unal.edu.co/index.php/biotecnologia/article/view/18536pruebas pin-on-diskcopa acetabularcabeza femoralsuero bovinotasa anual de desgastecoeficientes de fricciónTest Pin-on-Diskacetabular cupfemoral headbovine serumanual wearing |