Summary: | Background: The accuracy of fitness of any dental casting is imperative for the success of any prosthodontic treatment. From the time that dental casting was first introduced, efforts have been made to produce more accurate and better fitted castings with minimal marginal discrepancy. The aim of this in vitro study was to evaluate the effects of three different investing and burnout techniques on the vertical marginal discrepancies ofceramometalcopings invested with two types of phosphate- bonded investments.
Materials and methods: Sixty wax patterns were fabricated on a standardized prepared brass die representing an upper central incisor by the aid of a custom-made split mold. Three different investing and burnout techniques were applied for an Iraqi investment and a commercial type; Group I:Ring investing with conventional burnout technique (RC);Group II: Ringless investing with conventional burnout technique (RLC);Group III: Ring investing with accelerated burnout technique (RA).Twenty wax patterns of each group were divided into two subgroups according to the type of investment material used (10 for each subgroup) represented as (B) for the BellaStar XL and (W) for the WYMvest investments. Complete castings were finished and seated on the metal die. The accuracy of fit of each coping was determined by measuring the vertical marginal discrepancies between the finish line on the metal die and the margins of each coping at four specific reference points on the labial, mesial, palatal, and distal aspects of the die by the aid of a light microscope supplied with a digital camera.The arithmetic mean of each three records was computed and regarded as the amount of the marginal discrepancy of each coping and was used as a unit for the statistical analysis.
Results: Mean marginal accuracy for W(RLC)was found to be the least (13.839+4.5724 um) while the highest mean value related to B(RLC) (29.033+2.102 um). In general, ANOVA test showed significant results among the mean values of the Binvestment subgroups while LSD test showed non-significance between the (RA) and both the (RC) and (RLC) subgroups. On the other hand, significance was present between the (RLC) and (RA)of the Winvestment subgroups while non-significance was located between the (RC) and both the (RLC) and (RA) subgroups. Comparing similar subgroups of the two tested investments, the Student's t-test showed non-significance between the (RC) subgroups while high significance was located between the (RLC) and (RA) subgroups respectively.Concerning the vertical marginal discrepancy of the copings, applying the (RC) technique for both investments caused non-statistical significance between the labial, mesial, palatal, and distal aspects.The (RLC) technique caused high significance between the four aspects, while the (RA) technique caused non-significance between the labial aspect only and the others.
Conclusion: The Iraqi investment generally produced less vertical marginal discrepancies (using the three different investing and burn-out techniques) than the commercial investment.In order to achieve a better marginal fit, it seems that ceramometalcopings invested with the commercial investment tested are better be cast using the conventional ring investing and burnout technique.
|