The national program and Eliza test on tetanus profelaxy in Imam Hussein hospital, Tehran, Iran: a comparative study

Payesh2010; 9: 29-37Accepted for publication: 29 July 2008[EPub a head of print-7 March 2010] Objective(s): Injuries and realed wounds are one of the most common causes of admission in emergency departments. In this study the national protocol for tetanus prevention is compared with Eliza as the gol...

Full description

Bibliographic Details
Main Authors: Hamid Reza Hatamabadi, Ali Mohammadshahi, Mohammad Reza Sohrabi
Format: Article
Language:fas
Published: Iranian Institute for Health Sciences Research 2010-01-01
Series:Payesh
Subjects:
Online Access:http://payeshjournal.ir/article-1-586-en.html
id doaj-1c1044cd903e44bc9fb37bac481c038a
record_format Article
spelling doaj-1c1044cd903e44bc9fb37bac481c038a2020-11-25T04:07:47ZfasIranian Institute for Health Sciences ResearchPayesh1680-76262008-45362010-01-01912937The national program and Eliza test on tetanus profelaxy in Imam Hussein hospital, Tehran, Iran: a comparative studyHamid Reza Hatamabadi0Ali Mohammadshahi1Mohammad Reza Sohrabi2 Payesh2010; 9: 29-37Accepted for publication: 29 July 2008[EPub a head of print-7 March 2010] Objective(s): Injuries and realed wounds are one of the most common causes of admission in emergency departments. In this study the national protocol for tetanus prevention is compared with Eliza as the golden standard for detecting immunity of person.Methods: In a cross sectional study 200 individuals with wound admitted at Imam Hussein hospital (a teaching hospital in Tehran, Iran) were assessed and questionnaires were filled in based on physician decision as protocol recommended and also the result of Eliza. Agreement of physician decision and Eliza result has been evaluated by Kappa index. Sensitivity, specificity, predictive values, likelihood ratios and accuracy were also detected for different methods of vaccine and immunoglobulin administration.Results: Immunoglobulin was administered for 30 percent of persons and vaccine for 23.5 percent. Kappa index for agreement between protocol administration and real administration in emergency department was 0.307 for immunoglobulin and 0.136 for vaccine (p<0.05). It was 0.081 (P>0.05) and 0.199 (P<0.001) for agreement of protocol administration and Eliza and 0.008 and 0.054 (P>0.05) for agreement of administration in emergency depertment and Eliza respectively.For immunoglobuline sensitivity was 0.33, specificity 0.24, positive predictive value 0.25, negative predictive value 0.82, positive likelihood ratio 1.38, negative likelihood ratio 0.88 and accuracy 0.68. For vaccine sensitivity was 0.82, specificity 0.52, positive predictive value 0.29, negative predictive value 0.92, positive likelihood ratio 2.2, negative likelihood ratio 0.35 and accuracy 0.58.Conclusion: The sensitivity, specificity, predictive value, likelihood ratio and accuracy for national protocol are not enough for using in emergency department. It seems that there is need for another reliable and valid substitute method.http://payeshjournal.ir/article-1-586-en.htmltetanuspreventionsensitivityspecificitypredictive valuelikelihood ratioprecision
collection DOAJ
language fas
format Article
sources DOAJ
author Hamid Reza Hatamabadi
Ali Mohammadshahi
Mohammad Reza Sohrabi
spellingShingle Hamid Reza Hatamabadi
Ali Mohammadshahi
Mohammad Reza Sohrabi
The national program and Eliza test on tetanus profelaxy in Imam Hussein hospital, Tehran, Iran: a comparative study
Payesh
tetanus
prevention
sensitivity
specificity
predictive value
likelihood ratio
precision
author_facet Hamid Reza Hatamabadi
Ali Mohammadshahi
Mohammad Reza Sohrabi
author_sort Hamid Reza Hatamabadi
title The national program and Eliza test on tetanus profelaxy in Imam Hussein hospital, Tehran, Iran: a comparative study
title_short The national program and Eliza test on tetanus profelaxy in Imam Hussein hospital, Tehran, Iran: a comparative study
title_full The national program and Eliza test on tetanus profelaxy in Imam Hussein hospital, Tehran, Iran: a comparative study
title_fullStr The national program and Eliza test on tetanus profelaxy in Imam Hussein hospital, Tehran, Iran: a comparative study
title_full_unstemmed The national program and Eliza test on tetanus profelaxy in Imam Hussein hospital, Tehran, Iran: a comparative study
title_sort national program and eliza test on tetanus profelaxy in imam hussein hospital, tehran, iran: a comparative study
publisher Iranian Institute for Health Sciences Research
series Payesh
issn 1680-7626
2008-4536
publishDate 2010-01-01
description Payesh2010; 9: 29-37Accepted for publication: 29 July 2008[EPub a head of print-7 March 2010] Objective(s): Injuries and realed wounds are one of the most common causes of admission in emergency departments. In this study the national protocol for tetanus prevention is compared with Eliza as the golden standard for detecting immunity of person.Methods: In a cross sectional study 200 individuals with wound admitted at Imam Hussein hospital (a teaching hospital in Tehran, Iran) were assessed and questionnaires were filled in based on physician decision as protocol recommended and also the result of Eliza. Agreement of physician decision and Eliza result has been evaluated by Kappa index. Sensitivity, specificity, predictive values, likelihood ratios and accuracy were also detected for different methods of vaccine and immunoglobulin administration.Results: Immunoglobulin was administered for 30 percent of persons and vaccine for 23.5 percent. Kappa index for agreement between protocol administration and real administration in emergency department was 0.307 for immunoglobulin and 0.136 for vaccine (p<0.05). It was 0.081 (P>0.05) and 0.199 (P<0.001) for agreement of protocol administration and Eliza and 0.008 and 0.054 (P>0.05) for agreement of administration in emergency depertment and Eliza respectively.For immunoglobuline sensitivity was 0.33, specificity 0.24, positive predictive value 0.25, negative predictive value 0.82, positive likelihood ratio 1.38, negative likelihood ratio 0.88 and accuracy 0.68. For vaccine sensitivity was 0.82, specificity 0.52, positive predictive value 0.29, negative predictive value 0.92, positive likelihood ratio 2.2, negative likelihood ratio 0.35 and accuracy 0.58.Conclusion: The sensitivity, specificity, predictive value, likelihood ratio and accuracy for national protocol are not enough for using in emergency department. It seems that there is need for another reliable and valid substitute method.
topic tetanus
prevention
sensitivity
specificity
predictive value
likelihood ratio
precision
url http://payeshjournal.ir/article-1-586-en.html
work_keys_str_mv AT hamidrezahatamabadi thenationalprogramandelizatestontetanusprofelaxyinimamhusseinhospitaltehraniranacomparativestudy
AT alimohammadshahi thenationalprogramandelizatestontetanusprofelaxyinimamhusseinhospitaltehraniranacomparativestudy
AT mohammadrezasohrabi thenationalprogramandelizatestontetanusprofelaxyinimamhusseinhospitaltehraniranacomparativestudy
AT hamidrezahatamabadi nationalprogramandelizatestontetanusprofelaxyinimamhusseinhospitaltehraniranacomparativestudy
AT alimohammadshahi nationalprogramandelizatestontetanusprofelaxyinimamhusseinhospitaltehraniranacomparativestudy
AT mohammadrezasohrabi nationalprogramandelizatestontetanusprofelaxyinimamhusseinhospitaltehraniranacomparativestudy
_version_ 1724427993279889408