Optimal Design of LLC Resonant DC Transformer under Adaptive Frequency Tracking Strategy

In recent years, the LLC (inductor–inductor–capacitor) DC transformer has been widely used in communication and computer power supply because of its advantages of zero voltage conduction of primary switch and zero current turn off concerning the output rectifier diode. To obtain higher transmission...

Full description

Bibliographic Details
Main Authors: Yu Tang, Dekai Kong, Chenxu Duan, Hao Sun
Format: Article
Language:English
Published: MDPI AG 2020-12-01
Series:Electronics
Subjects:
Online Access:https://www.mdpi.com/2079-9292/9/12/2160
id doaj-1bc5e42850bf4950b4b344d1f0d2e434
record_format Article
spelling doaj-1bc5e42850bf4950b4b344d1f0d2e4342020-12-17T00:05:59ZengMDPI AGElectronics2079-92922020-12-0192160216010.3390/electronics9122160Optimal Design of LLC Resonant DC Transformer under Adaptive Frequency Tracking StrategyYu Tang0Dekai Kong1Chenxu Duan2Hao Sun3State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology, Tianjin 300000, ChinaKey Laboratory of Electromagnetic Field and Electrical Apparatus Reliability of Hebei Province, Hebei University of Technology, Tianjin 300000, ChinaKey Laboratory of Electromagnetic Field and Electrical Apparatus Reliability of Hebei Province, Hebei University of Technology, Tianjin 300000, ChinaKey Laboratory of Electromagnetic Field and Electrical Apparatus Reliability of Hebei Province, Hebei University of Technology, Tianjin 300000, ChinaIn recent years, the LLC (inductor–inductor–capacitor) DC transformer has been widely used in communication and computer power supply because of its advantages of zero voltage conduction of primary switch and zero current turn off concerning the output rectifier diode. To obtain higher transmission efficiency and make the LLC DC transformer always run at the optimal operating point, the switching frequency of the LLC DC transformer should work at the resonance frequency of the circuit. In actual conditions, the optimal operating frequency of the LLC DC transformer will be changed due to the influences of the working condition on the circuit parameters and the load change. Therefore, the LLC DC transformer controlled by the fixed frequency mode will not be in the best working condition. In this paper, an adaptive frequency tracking method is used to control the circuit; when the circuit parameters change, the LLC DC transformer can always be in the best working state. Then, the influence of circuit parameters such as output power and excitation inductor on the optimal working point of the LLC DC transformer is analyzed in detail. Finally, a 1 kW LLC resonant converter prototype is designed under laboratory conditions to verify the feasibility of the control strategy.https://www.mdpi.com/2079-9292/9/12/2160LLC resonant converterfrequency trackingDC transformer
collection DOAJ
language English
format Article
sources DOAJ
author Yu Tang
Dekai Kong
Chenxu Duan
Hao Sun
spellingShingle Yu Tang
Dekai Kong
Chenxu Duan
Hao Sun
Optimal Design of LLC Resonant DC Transformer under Adaptive Frequency Tracking Strategy
Electronics
LLC resonant converter
frequency tracking
DC transformer
author_facet Yu Tang
Dekai Kong
Chenxu Duan
Hao Sun
author_sort Yu Tang
title Optimal Design of LLC Resonant DC Transformer under Adaptive Frequency Tracking Strategy
title_short Optimal Design of LLC Resonant DC Transformer under Adaptive Frequency Tracking Strategy
title_full Optimal Design of LLC Resonant DC Transformer under Adaptive Frequency Tracking Strategy
title_fullStr Optimal Design of LLC Resonant DC Transformer under Adaptive Frequency Tracking Strategy
title_full_unstemmed Optimal Design of LLC Resonant DC Transformer under Adaptive Frequency Tracking Strategy
title_sort optimal design of llc resonant dc transformer under adaptive frequency tracking strategy
publisher MDPI AG
series Electronics
issn 2079-9292
publishDate 2020-12-01
description In recent years, the LLC (inductor–inductor–capacitor) DC transformer has been widely used in communication and computer power supply because of its advantages of zero voltage conduction of primary switch and zero current turn off concerning the output rectifier diode. To obtain higher transmission efficiency and make the LLC DC transformer always run at the optimal operating point, the switching frequency of the LLC DC transformer should work at the resonance frequency of the circuit. In actual conditions, the optimal operating frequency of the LLC DC transformer will be changed due to the influences of the working condition on the circuit parameters and the load change. Therefore, the LLC DC transformer controlled by the fixed frequency mode will not be in the best working condition. In this paper, an adaptive frequency tracking method is used to control the circuit; when the circuit parameters change, the LLC DC transformer can always be in the best working state. Then, the influence of circuit parameters such as output power and excitation inductor on the optimal working point of the LLC DC transformer is analyzed in detail. Finally, a 1 kW LLC resonant converter prototype is designed under laboratory conditions to verify the feasibility of the control strategy.
topic LLC resonant converter
frequency tracking
DC transformer
url https://www.mdpi.com/2079-9292/9/12/2160
work_keys_str_mv AT yutang optimaldesignofllcresonantdctransformerunderadaptivefrequencytrackingstrategy
AT dekaikong optimaldesignofllcresonantdctransformerunderadaptivefrequencytrackingstrategy
AT chenxuduan optimaldesignofllcresonantdctransformerunderadaptivefrequencytrackingstrategy
AT haosun optimaldesignofllcresonantdctransformerunderadaptivefrequencytrackingstrategy
_version_ 1724380596373815296