The Optimized Workflow for Sample Preparation in LC-MS/MS-Based Urine Proteomics

The sample condition is an important factor in urine proteomics with stability and accuracy. However, a general protocol of urine protein preparation in mass spectrometry analysis has not yet been established. Here, we proposed a workflow for optimized sample preparation based on methanol/chloroform...

Full description

Bibliographic Details
Main Authors: Suguru Saito, Yoshitoshi Hirao, Ali F. Quadery, Bo Xu, Amr Elguoshy, Hidehiko Fujinaka, Shohei Koma, Keiko Yamamoto, Tadashi Yamamoto
Format: Article
Language:English
Published: MDPI AG 2019-06-01
Series:Methods and Protocols
Subjects:
Online Access:https://www.mdpi.com/2409-9279/2/2/46
id doaj-1af18c2924354f96a331dd788c552534
record_format Article
spelling doaj-1af18c2924354f96a331dd788c5525342020-11-25T00:31:13ZengMDPI AGMethods and Protocols2409-92792019-06-01224610.3390/mps2020046mps2020046The Optimized Workflow for Sample Preparation in LC-MS/MS-Based Urine ProteomicsSuguru Saito0Yoshitoshi Hirao1Ali F. Quadery2Bo Xu3Amr Elguoshy4Hidehiko Fujinaka5Shohei Koma6Keiko Yamamoto7Tadashi Yamamoto8Biofluid Biomarker Center, Niigata University, Niigata 9502181, JapanBiofluid Biomarker Center, Niigata University, Niigata 9502181, JapanBiofluid Biomarker Center, Niigata University, Niigata 9502181, JapanBiofluid Biomarker Center, Niigata University, Niigata 9502181, JapanBiofluid Biomarker Center, Niigata University, Niigata 9502181, JapanBiofluid Biomarker Center, Niigata University, Niigata 9502181, JapanLife Science Research Laboratory, Tosoh Corporation, Kanagawa 252-1123, JapanBiofluid Biomarker Center, Niigata University, Niigata 9502181, JapanBiofluid Biomarker Center, Niigata University, Niigata 9502181, JapanThe sample condition is an important factor in urine proteomics with stability and accuracy. However, a general protocol of urine protein preparation in mass spectrometry analysis has not yet been established. Here, we proposed a workflow for optimized sample preparation based on methanol/chloroform (M/C) precipitation and in-solution trypsin digestion in LC-MS/MS-based urine proteomics. The urine proteins prepared by M/C precipitation showed around 80% of the protein recovery rate. The samples showed the largest number of identified proteins, which were over 1000 on average compared with other precipitation methods in LC-MS/MS-based urine proteomics. For further improvement of the workflow, the essences were arranged in protein dissolving and trypsin digestion step for the extraction of urine proteins. Addition of Ethylene diamine tetraacetic acid (EDTA) dramatically enhanced the dissolution of protein and promoted the trypsin activity in the digestion step because the treatment increased the number of identified proteins with less missed cleavage sites. Eventually, an optimized workflow was established by a well-organized strategy for daily use in the LC-MS/MS-based urine proteomics. The workflow will be of great help for several aims based on urine proteomics approaches, such as diagnosis and biomarker discovery.https://www.mdpi.com/2409-9279/2/2/46Urine proteomicsUrine protein precipitationUrine biomarker
collection DOAJ
language English
format Article
sources DOAJ
author Suguru Saito
Yoshitoshi Hirao
Ali F. Quadery
Bo Xu
Amr Elguoshy
Hidehiko Fujinaka
Shohei Koma
Keiko Yamamoto
Tadashi Yamamoto
spellingShingle Suguru Saito
Yoshitoshi Hirao
Ali F. Quadery
Bo Xu
Amr Elguoshy
Hidehiko Fujinaka
Shohei Koma
Keiko Yamamoto
Tadashi Yamamoto
The Optimized Workflow for Sample Preparation in LC-MS/MS-Based Urine Proteomics
Methods and Protocols
Urine proteomics
Urine protein precipitation
Urine biomarker
author_facet Suguru Saito
Yoshitoshi Hirao
Ali F. Quadery
Bo Xu
Amr Elguoshy
Hidehiko Fujinaka
Shohei Koma
Keiko Yamamoto
Tadashi Yamamoto
author_sort Suguru Saito
title The Optimized Workflow for Sample Preparation in LC-MS/MS-Based Urine Proteomics
title_short The Optimized Workflow for Sample Preparation in LC-MS/MS-Based Urine Proteomics
title_full The Optimized Workflow for Sample Preparation in LC-MS/MS-Based Urine Proteomics
title_fullStr The Optimized Workflow for Sample Preparation in LC-MS/MS-Based Urine Proteomics
title_full_unstemmed The Optimized Workflow for Sample Preparation in LC-MS/MS-Based Urine Proteomics
title_sort optimized workflow for sample preparation in lc-ms/ms-based urine proteomics
publisher MDPI AG
series Methods and Protocols
issn 2409-9279
publishDate 2019-06-01
description The sample condition is an important factor in urine proteomics with stability and accuracy. However, a general protocol of urine protein preparation in mass spectrometry analysis has not yet been established. Here, we proposed a workflow for optimized sample preparation based on methanol/chloroform (M/C) precipitation and in-solution trypsin digestion in LC-MS/MS-based urine proteomics. The urine proteins prepared by M/C precipitation showed around 80% of the protein recovery rate. The samples showed the largest number of identified proteins, which were over 1000 on average compared with other precipitation methods in LC-MS/MS-based urine proteomics. For further improvement of the workflow, the essences were arranged in protein dissolving and trypsin digestion step for the extraction of urine proteins. Addition of Ethylene diamine tetraacetic acid (EDTA) dramatically enhanced the dissolution of protein and promoted the trypsin activity in the digestion step because the treatment increased the number of identified proteins with less missed cleavage sites. Eventually, an optimized workflow was established by a well-organized strategy for daily use in the LC-MS/MS-based urine proteomics. The workflow will be of great help for several aims based on urine proteomics approaches, such as diagnosis and biomarker discovery.
topic Urine proteomics
Urine protein precipitation
Urine biomarker
url https://www.mdpi.com/2409-9279/2/2/46
work_keys_str_mv AT sugurusaito theoptimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT yoshitoshihirao theoptimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT alifquadery theoptimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT boxu theoptimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT amrelguoshy theoptimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT hidehikofujinaka theoptimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT shoheikoma theoptimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT keikoyamamoto theoptimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT tadashiyamamoto theoptimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT sugurusaito optimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT yoshitoshihirao optimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT alifquadery optimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT boxu optimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT amrelguoshy optimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT hidehikofujinaka optimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT shoheikoma optimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT keikoyamamoto optimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
AT tadashiyamamoto optimizedworkflowforsamplepreparationinlcmsmsbasedurineproteomics
_version_ 1725323054132756480