Increasing the heat transfer efficiency of sectional radiators in building heating systems

In heating systems of residential and public buildings, the sectional radiators are widely used as heating devices, where its heat transfer efficiency critically decreases, when the heat-carrying agent’s temperature lowered. At the same time, in order to increase the heat transfer efficiency of heat...

Full description

Bibliographic Details
Main Authors: A.P. Levsev, E.S. Lapin, Q. Zhang
Format: Article
Language:English
Published: Peter the Great St. Petersburg Polytechnic University 2019-12-01
Series:Инженерно-строительный журнал
Subjects:
Online Access:https://engstroy.spbstu.ru/userfiles/files/2019/8(92)/05.pdf
id doaj-1a7e50188ebf4d60bdb512aacdc5d838
record_format Article
spelling doaj-1a7e50188ebf4d60bdb512aacdc5d8382020-11-25T04:10:29ZengPeter the Great St. Petersburg Polytechnic UniversityИнженерно-строительный журнал2071-03052019-12-01928637510.18720/MCE.92.5Increasing the heat transfer efficiency of sectional radiators in building heating systemsA.P. Levsev0https://orcid.org/0000-0003-2429-6777E.S. Lapin1https://orcid.org/0000-0001-9647-8663Q. Zhang2National Research Ogarev Mordovia State UniversityNational Research Ogarev Mordovia State UniversityJiangsu University of Science and TechnologyIn heating systems of residential and public buildings, the sectional radiators are widely used as heating devices, where its heat transfer efficiency critically decreases, when the heat-carrying agent’s temperature lowered. At the same time, in order to increase the heat transfer efficiency of heat-exchange equipment, the positive experience of using the pulse flows is known. The heat supply method proposed in the process of the work performing, which consists in periodic supply of hot and cold heat-carrying agent through the sectional radiators. Thermal tests of 12 sectional radiators Rifar BASE 500 type at the temperatures from 42 °C to 67 °C and pulsation frequencies of the heat-carrying agent from 0.52 Hz to 0.62 Hz, showed an increase in their efficiency at the nominal flow rate of 1.8–2.2. With an increase in the flow rate and temperature of the heat-carrying agent, the SR efficiency decreases in a pulsating mode. The study of the SR efficiency from the parameters of the heating system and their switching circuit was carried out on a mathematical model in the form of energy chain that takes into account the mass and storage capacity of the heat-carrying agent. For a parallel connection up to 10 SR, the optimal circular frequency of the heat-carrying agent pulsations was 3 rad/s, and for a serial connection it was 4.2 rad/s, which is consistent with the results of thermal tests at the level of 7 %.https://engstroy.spbstu.ru/userfiles/files/2019/8(92)/05.pdfheat supply methodheating radiatorsheat-transfer efficiencyheat-carrying agent pulsationmembrane pumpheating unit
collection DOAJ
language English
format Article
sources DOAJ
author A.P. Levsev
E.S. Lapin
Q. Zhang
spellingShingle A.P. Levsev
E.S. Lapin
Q. Zhang
Increasing the heat transfer efficiency of sectional radiators in building heating systems
Инженерно-строительный журнал
heat supply method
heating radiators
heat-transfer efficiency
heat-carrying agent pulsation
membrane pump
heating unit
author_facet A.P. Levsev
E.S. Lapin
Q. Zhang
author_sort A.P. Levsev
title Increasing the heat transfer efficiency of sectional radiators in building heating systems
title_short Increasing the heat transfer efficiency of sectional radiators in building heating systems
title_full Increasing the heat transfer efficiency of sectional radiators in building heating systems
title_fullStr Increasing the heat transfer efficiency of sectional radiators in building heating systems
title_full_unstemmed Increasing the heat transfer efficiency of sectional radiators in building heating systems
title_sort increasing the heat transfer efficiency of sectional radiators in building heating systems
publisher Peter the Great St. Petersburg Polytechnic University
series Инженерно-строительный журнал
issn 2071-0305
publishDate 2019-12-01
description In heating systems of residential and public buildings, the sectional radiators are widely used as heating devices, where its heat transfer efficiency critically decreases, when the heat-carrying agent’s temperature lowered. At the same time, in order to increase the heat transfer efficiency of heat-exchange equipment, the positive experience of using the pulse flows is known. The heat supply method proposed in the process of the work performing, which consists in periodic supply of hot and cold heat-carrying agent through the sectional radiators. Thermal tests of 12 sectional radiators Rifar BASE 500 type at the temperatures from 42 °C to 67 °C and pulsation frequencies of the heat-carrying agent from 0.52 Hz to 0.62 Hz, showed an increase in their efficiency at the nominal flow rate of 1.8–2.2. With an increase in the flow rate and temperature of the heat-carrying agent, the SR efficiency decreases in a pulsating mode. The study of the SR efficiency from the parameters of the heating system and their switching circuit was carried out on a mathematical model in the form of energy chain that takes into account the mass and storage capacity of the heat-carrying agent. For a parallel connection up to 10 SR, the optimal circular frequency of the heat-carrying agent pulsations was 3 rad/s, and for a serial connection it was 4.2 rad/s, which is consistent with the results of thermal tests at the level of 7 %.
topic heat supply method
heating radiators
heat-transfer efficiency
heat-carrying agent pulsation
membrane pump
heating unit
url https://engstroy.spbstu.ru/userfiles/files/2019/8(92)/05.pdf
work_keys_str_mv AT aplevsev increasingtheheattransferefficiencyofsectionalradiatorsinbuildingheatingsystems
AT eslapin increasingtheheattransferefficiencyofsectionalradiatorsinbuildingheatingsystems
AT qzhang increasingtheheattransferefficiencyofsectionalradiatorsinbuildingheatingsystems
_version_ 1724420481331757056