Analysis of operating conditions of the voltage transformer

In electrical networks, constant monitoring of the electrical equipment operation is necessary. To accomplish this task, current transformers and voltage transformers (VT) are used, on which the accuracy of electrical measurements, electricity metering, and the reliability of the emergency control s...

Full description

Bibliographic Details
Main Authors: Fastiy G. P., Burtsev A. V., Karpov A. S., Yaroshevich V. V., Tokareva E. A.
Format: Article
Language:Russian
Published: Murmansk State Technical University 2017-12-01
Series:Vestnik MGTU
Subjects:
Online Access:http://vestnik.mstu.edu.ru/show-eng.shtml?art=1918
id doaj-1a6cc94cf7824c5d9460e4e3a29e8c2f
record_format Article
spelling doaj-1a6cc94cf7824c5d9460e4e3a29e8c2f2020-11-25T00:46:30ZrusMurmansk State Technical UniversityVestnik MGTU1560-92781997-47362017-12-0120471472210.21443/1560-9278-2017-20-4-714-722Analysis of operating conditions of the voltage transformerFastiy G. P.0Burtsev A. V.1Karpov A. S.2Yaroshevich V. V.3Tokareva E. A.4Centre for Physical and Technological Problems of Energy in Northern Areas KSC RASCentre for Physical and Technological Problems of Energy in Northern Areas KSC RASCentre for Physical and Technological Problems of Energy in Northern Areas KSC RASCentre for Physical and Technological Problems of Energy in Northern Areas KSC RASCentre for Physical and Technological Problems of Energy in Northern Areas KSC RASIn electrical networks, constant monitoring of the electrical equipment operation is necessary. To accomplish this task, current transformers and voltage transformers (VT) are used, on which the accuracy of electrical measurements, electricity metering, and the reliability of the emergency control system depend. The results of the analysis of the conditions for forming the magnetization of a voltage transformer in the mode with unilateral connection of overhead transmission lines, as well as variants of violations in the 110 kV network that may exist for a relatively long time have been presented. It should be noted that the considered network has its own peculiarities: the overhead transmission lines connected in series have a significant length and a low level of load, which may be a condition for the appearance of a transmission lines capacitive effect (the Ferranti effect), the latter can cause overvoltage. Overvoltage occurs when the operating modes are temporary in terms of operation, adverse combinations of network parameters take place, and can continue until the circuit and network modes change. Most often they appear in asymmetric modes, with short circuits to ground, etc. Asymmetric modes caused by incomplete-phase commutations and wire breaks on the overhead line, as well as wire breaks with subsequent disconnection of power transformers that can affect the voltage level on the VT have been considered. The possibility of VT magnetizing with a prolonged voltage rise in symmetric modes, namely, the manifestation of the Ferranti effect with various loads at substations up to complete switching-off and power transformers switching off has been investigated. The analysis of the measuring voltage transformer operating conditions has been based on materials provided by the "Kolenergo" services.http://vestnik.mstu.edu.ru/show-eng.shtml?art=1918voltage transformersubstationunbalanced modepower linepower transformerwire break
collection DOAJ
language Russian
format Article
sources DOAJ
author Fastiy G. P.
Burtsev A. V.
Karpov A. S.
Yaroshevich V. V.
Tokareva E. A.
spellingShingle Fastiy G. P.
Burtsev A. V.
Karpov A. S.
Yaroshevich V. V.
Tokareva E. A.
Analysis of operating conditions of the voltage transformer
Vestnik MGTU
voltage transformer
substation
unbalanced mode
power line
power transformer
wire break
author_facet Fastiy G. P.
Burtsev A. V.
Karpov A. S.
Yaroshevich V. V.
Tokareva E. A.
author_sort Fastiy G. P.
title Analysis of operating conditions of the voltage transformer
title_short Analysis of operating conditions of the voltage transformer
title_full Analysis of operating conditions of the voltage transformer
title_fullStr Analysis of operating conditions of the voltage transformer
title_full_unstemmed Analysis of operating conditions of the voltage transformer
title_sort analysis of operating conditions of the voltage transformer
publisher Murmansk State Technical University
series Vestnik MGTU
issn 1560-9278
1997-4736
publishDate 2017-12-01
description In electrical networks, constant monitoring of the electrical equipment operation is necessary. To accomplish this task, current transformers and voltage transformers (VT) are used, on which the accuracy of electrical measurements, electricity metering, and the reliability of the emergency control system depend. The results of the analysis of the conditions for forming the magnetization of a voltage transformer in the mode with unilateral connection of overhead transmission lines, as well as variants of violations in the 110 kV network that may exist for a relatively long time have been presented. It should be noted that the considered network has its own peculiarities: the overhead transmission lines connected in series have a significant length and a low level of load, which may be a condition for the appearance of a transmission lines capacitive effect (the Ferranti effect), the latter can cause overvoltage. Overvoltage occurs when the operating modes are temporary in terms of operation, adverse combinations of network parameters take place, and can continue until the circuit and network modes change. Most often they appear in asymmetric modes, with short circuits to ground, etc. Asymmetric modes caused by incomplete-phase commutations and wire breaks on the overhead line, as well as wire breaks with subsequent disconnection of power transformers that can affect the voltage level on the VT have been considered. The possibility of VT magnetizing with a prolonged voltage rise in symmetric modes, namely, the manifestation of the Ferranti effect with various loads at substations up to complete switching-off and power transformers switching off has been investigated. The analysis of the measuring voltage transformer operating conditions has been based on materials provided by the "Kolenergo" services.
topic voltage transformer
substation
unbalanced mode
power line
power transformer
wire break
url http://vestnik.mstu.edu.ru/show-eng.shtml?art=1918
work_keys_str_mv AT fastiygp analysisofoperatingconditionsofthevoltagetransformer
AT burtsevav analysisofoperatingconditionsofthevoltagetransformer
AT karpovas analysisofoperatingconditionsofthevoltagetransformer
AT yaroshevichvv analysisofoperatingconditionsofthevoltagetransformer
AT tokarevaea analysisofoperatingconditionsofthevoltagetransformer
_version_ 1725264950956392448