A Technique for Treatment of Overdrainage in Ventriculoperitoneal Shunt

Background and Importance: Overdrainage is a complication of ventriculoperitoneal shunt but adjustable valves and anti-siphon devices can prevent it. These very expensive valves are most often inaccessible, so that the majority of the valves available in Togo are fixed differential pressure valves....

Full description

Bibliographic Details
Main Authors: Essossinam Kpélao *, Katanga Anthony Békéti, Abdel Kader Moumouni, Kodjo Mensah Hobli-Ahanogbé, Agbéko Komlan Doléagbenou, Komi Egu, Thierry Alihonou, Essosolim Hodabalo Bakondé, Pilakimwé Egbohou, Assang Dossim
Format: Article
Language:English
Published: Guilan University of Medical Sciences 2017-09-01
Series:Iranian Journal of Neurosurgery
Subjects:
Online Access:http://irjns.org/browse.php?a_code=A-10-172-2&slc_lang=en&sid=1
id doaj-1a11c04ce8ed423a868ca51d7cea62f8
record_format Article
spelling doaj-1a11c04ce8ed423a868ca51d7cea62f82021-04-02T19:58:29ZengGuilan University of Medical SciencesIranian Journal of Neurosurgery2423-64972423-68292017-09-01325862A Technique for Treatment of Overdrainage in Ventriculoperitoneal ShuntEssossinam Kpélao *0Katanga Anthony Békéti1Abdel Kader Moumouni2Kodjo Mensah Hobli-Ahanogbé3Agbéko Komlan Doléagbenou4Komi Egu5Thierry Alihonou6Essosolim Hodabalo Bakondé7Pilakimwé Egbohou8Assang Dossim9 Department of Neurosurgery, Sylvanus Olympio University Hospital, Lomé, Togo Department of Neurosurgery, Sylvanus Olympio University Hospital, Lomé, Togo Department of Neurosurgery, Sylvanus Olympio University Hospital, Lomé, Togo Department of Neurosurgery, Sylvanus Olympio University Hospital, Lomé, Togo Department of Neurosurgery, Sylvanus Olympio University Hospital, Lomé, Togo Department of Neurosurgery, Sylvanus Olympio University Hospital, Lomé, Togo Department of Surgery University Hospital Center of Ouémé and Plateau, Benin Department of Neurosurgery, Sylvanus Olympio University Hospital, Lomé, Togo Intensive Care Unit, Sylvanus Olympio University Hospital, Lomé, Togo Department of Neurosurgery, Sylvanus Olympio University Hospital, Lomé, Togo Background and Importance: Overdrainage is a complication of ventriculoperitoneal shunt but adjustable valves and anti-siphon devices can prevent it. These very expensive valves are most often inaccessible, so that the majority of the valves available in Togo are fixed differential pressure valves. Although overdrainage is a widely-known issue, we aimed to introduce a new risk factor and the way we manage this complication. Case Presentation: This case series study included all patients who had overdrainage or a high potential risk of overdrainage (hydranencephaly). Our technique consisted of partial ligation of the peritoneal catheter at the level of the thorax by non-resorbable wire while controlling the drainage rate at the slots. The goal was to transform this fixed differential pressure valve into a pressure-controlled and flow-regulated one. Patients were followed for 1, 3 and 6 months, postoperatively.                                    Conclusion: Hydranencephaly predisposes patients to overdrainage. The partial ligature of the catheter is an effective technique for treating or preventing overdrainage.http://irjns.org/browse.php?a_code=A-10-172-2&slc_lang=en&sid=1OverdrainageLigationCatheter
collection DOAJ
language English
format Article
sources DOAJ
author Essossinam Kpélao *
Katanga Anthony Békéti
Abdel Kader Moumouni
Kodjo Mensah Hobli-Ahanogbé
Agbéko Komlan Doléagbenou
Komi Egu
Thierry Alihonou
Essosolim Hodabalo Bakondé
Pilakimwé Egbohou
Assang Dossim
spellingShingle Essossinam Kpélao *
Katanga Anthony Békéti
Abdel Kader Moumouni
Kodjo Mensah Hobli-Ahanogbé
Agbéko Komlan Doléagbenou
Komi Egu
Thierry Alihonou
Essosolim Hodabalo Bakondé
Pilakimwé Egbohou
Assang Dossim
A Technique for Treatment of Overdrainage in Ventriculoperitoneal Shunt
Iranian Journal of Neurosurgery
Overdrainage
Ligation
Catheter
author_facet Essossinam Kpélao *
Katanga Anthony Békéti
Abdel Kader Moumouni
Kodjo Mensah Hobli-Ahanogbé
Agbéko Komlan Doléagbenou
Komi Egu
Thierry Alihonou
Essosolim Hodabalo Bakondé
Pilakimwé Egbohou
Assang Dossim
author_sort Essossinam Kpélao *
title A Technique for Treatment of Overdrainage in Ventriculoperitoneal Shunt
title_short A Technique for Treatment of Overdrainage in Ventriculoperitoneal Shunt
title_full A Technique for Treatment of Overdrainage in Ventriculoperitoneal Shunt
title_fullStr A Technique for Treatment of Overdrainage in Ventriculoperitoneal Shunt
title_full_unstemmed A Technique for Treatment of Overdrainage in Ventriculoperitoneal Shunt
title_sort technique for treatment of overdrainage in ventriculoperitoneal shunt
publisher Guilan University of Medical Sciences
series Iranian Journal of Neurosurgery
issn 2423-6497
2423-6829
publishDate 2017-09-01
description Background and Importance: Overdrainage is a complication of ventriculoperitoneal shunt but adjustable valves and anti-siphon devices can prevent it. These very expensive valves are most often inaccessible, so that the majority of the valves available in Togo are fixed differential pressure valves. Although overdrainage is a widely-known issue, we aimed to introduce a new risk factor and the way we manage this complication. Case Presentation: This case series study included all patients who had overdrainage or a high potential risk of overdrainage (hydranencephaly). Our technique consisted of partial ligation of the peritoneal catheter at the level of the thorax by non-resorbable wire while controlling the drainage rate at the slots. The goal was to transform this fixed differential pressure valve into a pressure-controlled and flow-regulated one. Patients were followed for 1, 3 and 6 months, postoperatively.                                    Conclusion: Hydranencephaly predisposes patients to overdrainage. The partial ligature of the catheter is an effective technique for treating or preventing overdrainage.
topic Overdrainage
Ligation
Catheter
url http://irjns.org/browse.php?a_code=A-10-172-2&slc_lang=en&sid=1
work_keys_str_mv AT essossinamkpelao atechniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT katangaanthonybeketi atechniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT abdelkadermoumouni atechniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT kodjomensahhobliahanogbe atechniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT agbekokomlandoleagbenou atechniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT komiegu atechniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT thierryalihonou atechniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT essosolimhodabalobakonde atechniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT pilakimweegbohou atechniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT assangdossim atechniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT essossinamkpelao techniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT katangaanthonybeketi techniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT abdelkadermoumouni techniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT kodjomensahhobliahanogbe techniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT agbekokomlandoleagbenou techniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT komiegu techniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT thierryalihonou techniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT essosolimhodabalobakonde techniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT pilakimweegbohou techniquefortreatmentofoverdrainageinventriculoperitonealshunt
AT assangdossim techniquefortreatmentofoverdrainageinventriculoperitonealshunt
_version_ 1721548104711274496