Carbon monoxide production from five volatile anesthetics in dry sodalime in a patient model: halothane and sevoflurane do produce carbon monoxide; temperature is a poor predictor of carbon monoxide production
<p>Abstract</p> <p>Background</p> <p>Desflurane and enflurane have been reported to produce substantial amounts of carbon monoxide (CO) in desiccated sodalime. Isoflurane is said to produce less CO and sevoflurane and halothane should produce no CO at all.</p> <...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
BMC
2005-06-01
|
Series: | BMC Anesthesiology |
Online Access: | http://www.biomedcentral.com/1471-2253/5/6 |
id |
doaj-19be49b323d64b2d842f16cf6fcfbac3 |
---|---|
record_format |
Article |
spelling |
doaj-19be49b323d64b2d842f16cf6fcfbac32020-11-25T02:50:03ZengBMCBMC Anesthesiology1471-22532005-06-0151610.1186/1471-2253-5-6Carbon monoxide production from five volatile anesthetics in dry sodalime in a patient model: halothane and sevoflurane do produce carbon monoxide; temperature is a poor predictor of carbon monoxide productionPerez Roberto SGMKeijzer ChristiaanDe Lange Jaap J<p>Abstract</p> <p>Background</p> <p>Desflurane and enflurane have been reported to produce substantial amounts of carbon monoxide (CO) in desiccated sodalime. Isoflurane is said to produce less CO and sevoflurane and halothane should produce no CO at all.</p> <p>The purpose of this study is to measure the maximum amounts of CO production for all modern volatile anesthetics, with completely dry sodalime. We also tried to establish a relationship between CO production and temperature increase inside the sodalime.</p> <p>Methods</p> <p>A patient model was simulated using a circle anesthesia system connected to an artificial lung. Completely desiccated sodalime (950 grams) was used in this system. A low flow anesthesia (500 ml/min) was maintained using nitrous oxide with desflurane, enflurane, isoflurane, halothane or sevoflurane. For immediate quantification of CO production a portable gas chromatograph was used. Temperature was measured within the sodalime container.</p> <p>Results</p> <p>Peak concentrations of CO were very high with desflurane and enflurane (14262 and 10654 ppm respectively). It was lower with isoflurane (2512 ppm). We also measured small concentrations of CO for sevoflurane and halothane. No significant temperature increases were detected with high CO productions.</p> <p>Conclusion</p> <p>All modern volatile anesthetics produce CO in desiccated sodalime. Sodalime temperature increase is a poor predictor of CO production.</p> http://www.biomedcentral.com/1471-2253/5/6 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Perez Roberto SGM Keijzer Christiaan De Lange Jaap J |
spellingShingle |
Perez Roberto SGM Keijzer Christiaan De Lange Jaap J Carbon monoxide production from five volatile anesthetics in dry sodalime in a patient model: halothane and sevoflurane do produce carbon monoxide; temperature is a poor predictor of carbon monoxide production BMC Anesthesiology |
author_facet |
Perez Roberto SGM Keijzer Christiaan De Lange Jaap J |
author_sort |
Perez Roberto SGM |
title |
Carbon monoxide production from five volatile anesthetics in dry sodalime in a patient model: halothane and sevoflurane do produce carbon monoxide; temperature is a poor predictor of carbon monoxide production |
title_short |
Carbon monoxide production from five volatile anesthetics in dry sodalime in a patient model: halothane and sevoflurane do produce carbon monoxide; temperature is a poor predictor of carbon monoxide production |
title_full |
Carbon monoxide production from five volatile anesthetics in dry sodalime in a patient model: halothane and sevoflurane do produce carbon monoxide; temperature is a poor predictor of carbon monoxide production |
title_fullStr |
Carbon monoxide production from five volatile anesthetics in dry sodalime in a patient model: halothane and sevoflurane do produce carbon monoxide; temperature is a poor predictor of carbon monoxide production |
title_full_unstemmed |
Carbon monoxide production from five volatile anesthetics in dry sodalime in a patient model: halothane and sevoflurane do produce carbon monoxide; temperature is a poor predictor of carbon monoxide production |
title_sort |
carbon monoxide production from five volatile anesthetics in dry sodalime in a patient model: halothane and sevoflurane do produce carbon monoxide; temperature is a poor predictor of carbon monoxide production |
publisher |
BMC |
series |
BMC Anesthesiology |
issn |
1471-2253 |
publishDate |
2005-06-01 |
description |
<p>Abstract</p> <p>Background</p> <p>Desflurane and enflurane have been reported to produce substantial amounts of carbon monoxide (CO) in desiccated sodalime. Isoflurane is said to produce less CO and sevoflurane and halothane should produce no CO at all.</p> <p>The purpose of this study is to measure the maximum amounts of CO production for all modern volatile anesthetics, with completely dry sodalime. We also tried to establish a relationship between CO production and temperature increase inside the sodalime.</p> <p>Methods</p> <p>A patient model was simulated using a circle anesthesia system connected to an artificial lung. Completely desiccated sodalime (950 grams) was used in this system. A low flow anesthesia (500 ml/min) was maintained using nitrous oxide with desflurane, enflurane, isoflurane, halothane or sevoflurane. For immediate quantification of CO production a portable gas chromatograph was used. Temperature was measured within the sodalime container.</p> <p>Results</p> <p>Peak concentrations of CO were very high with desflurane and enflurane (14262 and 10654 ppm respectively). It was lower with isoflurane (2512 ppm). We also measured small concentrations of CO for sevoflurane and halothane. No significant temperature increases were detected with high CO productions.</p> <p>Conclusion</p> <p>All modern volatile anesthetics produce CO in desiccated sodalime. Sodalime temperature increase is a poor predictor of CO production.</p> |
url |
http://www.biomedcentral.com/1471-2253/5/6 |
work_keys_str_mv |
AT perezrobertosgm carbonmonoxideproductionfromfivevolatileanestheticsindrysodalimeinapatientmodelhalothaneandsevofluranedoproducecarbonmonoxidetemperatureisapoorpredictorofcarbonmonoxideproduction AT keijzerchristiaan carbonmonoxideproductionfromfivevolatileanestheticsindrysodalimeinapatientmodelhalothaneandsevofluranedoproducecarbonmonoxidetemperatureisapoorpredictorofcarbonmonoxideproduction AT delangejaapj carbonmonoxideproductionfromfivevolatileanestheticsindrysodalimeinapatientmodelhalothaneandsevofluranedoproducecarbonmonoxidetemperatureisapoorpredictorofcarbonmonoxideproduction |
_version_ |
1724740500990197760 |