Using Flexible Curved Noncontact Active Electrodes to Monitor Long-Term Heart Rate Variability
The purpose of this study is to utilize flexible curved noncontact active electrodes to develop a nonperception, long-term, and wireless heart rate monitoring system. This study also verified the functions and capabilities of the system and provided information on physiological parameters recorded d...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2020-01-01
|
Series: | Journal of Healthcare Engineering |
Online Access: | http://dx.doi.org/10.1155/2020/8867712 |
id |
doaj-19431fd0c3a4461086c3871d52178d04 |
---|---|
record_format |
Article |
spelling |
doaj-19431fd0c3a4461086c3871d52178d042020-11-25T03:12:38ZengHindawi LimitedJournal of Healthcare Engineering2040-22952040-23092020-01-01202010.1155/2020/88677128867712Using Flexible Curved Noncontact Active Electrodes to Monitor Long-Term Heart Rate VariabilityJi-Jer Huang0Zhe-Lin Cai1Department of Electrical Engineering, Southern Taiwan University of Science and Technology, Tainan City 71005, TaiwanDepartment of Electrical Engineering, Southern Taiwan University of Science and Technology, Tainan City 71005, TaiwanThe purpose of this study is to utilize flexible curved noncontact active electrodes to develop a nonperception, long-term, and wireless heart rate monitoring system. This study also verified the functions and capabilities of the system and provided information on physiological parameters recorded during our tests. Our system was used in tandem with a commercially standard measurement system; both systems were used to measure ECG signals on 10 healthy subjects under the simulated home and office scenarios. We verified the R-peak measurement accuracy of our system and used T-tests to analyze the data collected by both systems; our system reached an average sensitivity value of 0.983 and an average positive predictive value of 0.991 over several different scenarios where R-peak measurements were also highly accurate. The R-R time intervals of our system were highly consistent with the standard system. The correlation coefficient calculated reached almost one, and the differences between the two systems mostly fell within the ±10 ms range. Further study of the HRV time-domain parameters under four different scenarios showed no significant differences in most HRV parameters compared to the measurements by the standard system. We also used our system to record long-term heart rate signals.http://dx.doi.org/10.1155/2020/8867712 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Ji-Jer Huang Zhe-Lin Cai |
spellingShingle |
Ji-Jer Huang Zhe-Lin Cai Using Flexible Curved Noncontact Active Electrodes to Monitor Long-Term Heart Rate Variability Journal of Healthcare Engineering |
author_facet |
Ji-Jer Huang Zhe-Lin Cai |
author_sort |
Ji-Jer Huang |
title |
Using Flexible Curved Noncontact Active Electrodes to Monitor Long-Term Heart Rate Variability |
title_short |
Using Flexible Curved Noncontact Active Electrodes to Monitor Long-Term Heart Rate Variability |
title_full |
Using Flexible Curved Noncontact Active Electrodes to Monitor Long-Term Heart Rate Variability |
title_fullStr |
Using Flexible Curved Noncontact Active Electrodes to Monitor Long-Term Heart Rate Variability |
title_full_unstemmed |
Using Flexible Curved Noncontact Active Electrodes to Monitor Long-Term Heart Rate Variability |
title_sort |
using flexible curved noncontact active electrodes to monitor long-term heart rate variability |
publisher |
Hindawi Limited |
series |
Journal of Healthcare Engineering |
issn |
2040-2295 2040-2309 |
publishDate |
2020-01-01 |
description |
The purpose of this study is to utilize flexible curved noncontact active electrodes to develop a nonperception, long-term, and wireless heart rate monitoring system. This study also verified the functions and capabilities of the system and provided information on physiological parameters recorded during our tests. Our system was used in tandem with a commercially standard measurement system; both systems were used to measure ECG signals on 10 healthy subjects under the simulated home and office scenarios. We verified the R-peak measurement accuracy of our system and used T-tests to analyze the data collected by both systems; our system reached an average sensitivity value of 0.983 and an average positive predictive value of 0.991 over several different scenarios where R-peak measurements were also highly accurate. The R-R time intervals of our system were highly consistent with the standard system. The correlation coefficient calculated reached almost one, and the differences between the two systems mostly fell within the ±10 ms range. Further study of the HRV time-domain parameters under four different scenarios showed no significant differences in most HRV parameters compared to the measurements by the standard system. We also used our system to record long-term heart rate signals. |
url |
http://dx.doi.org/10.1155/2020/8867712 |
work_keys_str_mv |
AT jijerhuang usingflexiblecurvednoncontactactiveelectrodestomonitorlongtermheartratevariability AT zhelincai usingflexiblecurvednoncontactactiveelectrodestomonitorlongtermheartratevariability |
_version_ |
1715276807856455680 |