Methods for Early Detection of Microbiological Infestation of Buildings Based on Gas Sensor Technologies
In this review, the problem of microbiological infestation of buildings was discussed. The techniques of detection were described as well, with special attention drawn to the rapid-early detection methods based on gas sensor arrays. The physical and chemical conditions of the building environment co...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-01-01
|
Series: | Chemosensors |
Subjects: | |
Online Access: | https://www.mdpi.com/2227-9040/8/1/7 |
id |
doaj-18f4903a98fb4ba6b741795d8dd9d8e8 |
---|---|
record_format |
Article |
spelling |
doaj-18f4903a98fb4ba6b741795d8dd9d8e82020-11-25T03:00:54ZengMDPI AGChemosensors2227-90402020-01-0181710.3390/chemosensors8010007chemosensors8010007Methods for Early Detection of Microbiological Infestation of Buildings Based on Gas Sensor TechnologiesMonika Garbacz0Agnieszka Malec1Sylwia Duda-Saternus2Zbigniew Suchorab3Łukasz Guz4Grzegorz Łagód5Department of Woman Health, Institute of Rural Health in Lublin, 20-090 Lublin, PolandFaculty of Environmental Engineering, Lublin University of Technology, 20-618 Lublin, PolandDepartment of Woman Health, Institute of Rural Health in Lublin, 20-090 Lublin, PolandFaculty of Environmental Engineering, Lublin University of Technology, 20-618 Lublin, PolandFaculty of Environmental Engineering, Lublin University of Technology, 20-618 Lublin, PolandFaculty of Environmental Engineering, Lublin University of Technology, 20-618 Lublin, PolandIn this review, the problem of microbiological infestation of buildings was discussed. The techniques of detection were described as well, with special attention drawn to the rapid-early detection methods based on gas sensor arrays. The physical and chemical conditions of the building environment conducive to the development of microorganisms and the technical conditions influencing the problem of microbiological infestation were investigated. Additionally, the harmful effects on human health caused by the microbiological contamination were discussed, with a short review of particular groups of microorganisms causing sick building syndrome. Among the detection techniques, the traditional microbiological techniques as well as the molecular and chemical methods were presented. Different designs of the gas sensor arrays together with the various techniques of analyzing the received multidimensional signal were described, analyzed, and compared in detail.https://www.mdpi.com/2227-9040/8/1/7microbiological infestationmoldfungigas sensor arrayelectronic nosevoc detectionchromatographypcrngssbs |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Monika Garbacz Agnieszka Malec Sylwia Duda-Saternus Zbigniew Suchorab Łukasz Guz Grzegorz Łagód |
spellingShingle |
Monika Garbacz Agnieszka Malec Sylwia Duda-Saternus Zbigniew Suchorab Łukasz Guz Grzegorz Łagód Methods for Early Detection of Microbiological Infestation of Buildings Based on Gas Sensor Technologies Chemosensors microbiological infestation mold fungi gas sensor array electronic nose voc detection chromatography pcr ngs sbs |
author_facet |
Monika Garbacz Agnieszka Malec Sylwia Duda-Saternus Zbigniew Suchorab Łukasz Guz Grzegorz Łagód |
author_sort |
Monika Garbacz |
title |
Methods for Early Detection of Microbiological Infestation of Buildings Based on Gas Sensor Technologies |
title_short |
Methods for Early Detection of Microbiological Infestation of Buildings Based on Gas Sensor Technologies |
title_full |
Methods for Early Detection of Microbiological Infestation of Buildings Based on Gas Sensor Technologies |
title_fullStr |
Methods for Early Detection of Microbiological Infestation of Buildings Based on Gas Sensor Technologies |
title_full_unstemmed |
Methods for Early Detection of Microbiological Infestation of Buildings Based on Gas Sensor Technologies |
title_sort |
methods for early detection of microbiological infestation of buildings based on gas sensor technologies |
publisher |
MDPI AG |
series |
Chemosensors |
issn |
2227-9040 |
publishDate |
2020-01-01 |
description |
In this review, the problem of microbiological infestation of buildings was discussed. The techniques of detection were described as well, with special attention drawn to the rapid-early detection methods based on gas sensor arrays. The physical and chemical conditions of the building environment conducive to the development of microorganisms and the technical conditions influencing the problem of microbiological infestation were investigated. Additionally, the harmful effects on human health caused by the microbiological contamination were discussed, with a short review of particular groups of microorganisms causing sick building syndrome. Among the detection techniques, the traditional microbiological techniques as well as the molecular and chemical methods were presented. Different designs of the gas sensor arrays together with the various techniques of analyzing the received multidimensional signal were described, analyzed, and compared in detail. |
topic |
microbiological infestation mold fungi gas sensor array electronic nose voc detection chromatography pcr ngs sbs |
url |
https://www.mdpi.com/2227-9040/8/1/7 |
work_keys_str_mv |
AT monikagarbacz methodsforearlydetectionofmicrobiologicalinfestationofbuildingsbasedongassensortechnologies AT agnieszkamalec methodsforearlydetectionofmicrobiologicalinfestationofbuildingsbasedongassensortechnologies AT sylwiadudasaternus methodsforearlydetectionofmicrobiologicalinfestationofbuildingsbasedongassensortechnologies AT zbigniewsuchorab methodsforearlydetectionofmicrobiologicalinfestationofbuildingsbasedongassensortechnologies AT łukaszguz methodsforearlydetectionofmicrobiologicalinfestationofbuildingsbasedongassensortechnologies AT grzegorzłagod methodsforearlydetectionofmicrobiologicalinfestationofbuildingsbasedongassensortechnologies |
_version_ |
1724696095142969344 |