Inadequate glucose control in type 2 diabetes is associated with impaired lung function and systemic inflammation: a cross-sectional study

<p>Abstract</p> <p>Background</p> <p>Inadequate glucose control may be simultaneously associated with inflammation and decreased lung function in type 2 diabetes. We evaluated if lung function is worse in patients with inadequate glucose control, and if inflammatory mar...

Full description

Bibliographic Details
Main Authors: Rondón Martin, Aschner Pablo, Rojas Maria X, Maldonado Dario, Dennis Rodolfo J, Charry Laura, Casas Alejandro
Format: Article
Language:English
Published: BMC 2010-07-01
Series:BMC Pulmonary Medicine
Online Access:http://www.biomedcentral.com/1471-2466/10/38
Description
Summary:<p>Abstract</p> <p>Background</p> <p>Inadequate glucose control may be simultaneously associated with inflammation and decreased lung function in type 2 diabetes. We evaluated if lung function is worse in patients with inadequate glucose control, and if inflammatory markers are simultaneously increased in these subjects.</p> <p>Methods</p> <p>Subjects were selected at the Colombian Diabetes Association Center in Bogotá. Pulmonary function tests were performed and mean residual values were obtained for forced expiratory volume (FEV<sub>1)</sub>, forced vital capacity (FVC) and FEV<sub>1</sub>/FVC, with predicted values based on those derived by Hankinson et al. for Mexican-Americans. Multiple least-squares regression was used to adjust for differences in known determinants of lung function. We measured blood levels of glycosylated hemoglobin (HBA<sub>1c</sub>), interleukin 6 (IL-6), tumor necrosis factor (TNF-α), fibrinogen, ferritin, and C-reactive protein (C-RP).</p> <p>Results</p> <p>495 diabetic patients were studied, out of which 352 had inadequate control (HBA<sub>1c </sub>> 7%). After adjusting for known determinants of lung function, those with inadequate control had lower FEV<sub>1 </sub>(-75.4 mL, IC95%: -92, -59; P < 0.0001) and FVC (-121 mL, IC95%: -134, -108; P < 0,0001) mean residuals, and higher FEV<sub>1</sub>/FVC (0.013%, IC95%: 0.009, 0.018, P < 0.0001) residuals than those with adequate control, as well as increased levels of all inflammatory markers (P < 0.05), with the exception of IL-6.</p> <p>Conclusions</p> <p>Subjects with type 2 diabetes and inadequate control had lower FVC and FEV<sub>1 </sub>than predicted and than those of subjects with adequate control. It is postulated that poorer pulmonary function may be associated with increased levels of inflammatory mediators.</p>
ISSN:1471-2466