Contribution of the Steady State Method to Water Permeability Measurement in Very Low Permeability Porous Media Contribution de la méthode stationnaire dans les mesures des très faibles perméabilités à l’eau

Very low permeability geomaterials (order of nanoDarcy (10-21 m2)), such as clay rocks, are of interest for many industrial applications including production from unconventional reserves of oil and gas, CO2 geological storage and deep geological disposal of high-level long-lived radioactive waste. I...

Full description

Bibliographic Details
Main Authors: Boulin P.F., Bretonnier P., Gland N., Lombard J.M.
Format: Article
Language:English
Published: EDP Sciences 2012-04-01
Series:Oil & Gas Science and Technology
Online Access:http://dx.doi.org/10.2516/ogst/2011169
Description
Summary:Very low permeability geomaterials (order of nanoDarcy (10-21 m2)), such as clay rocks, are of interest for many industrial applications including production from unconventional reserves of oil and gas, CO2 geological storage and deep geological disposal of high-level long-lived radioactive waste. In these last two applications, the efficiency of clay, as a barrier, relies on their very low permeability. Yet, laboratory measurement of low permeability to water (below 100 nD (10-19 m2)) remains a technical challenge. Some authors (Hsieh et al., 1981, Int. J. Rock Mech. Min. Sci. Geomech. Abstr. 18, 245-252) argue that steady state methods are irrelevant due to the time required to stabilize water fluxes in such low permeability media and prefer a transient technique called pulse decay. This study aims to perform and compare transient and steady state techniques on three samples. Regarding the steady state method, a high precision pump was used to measure water flow rate through the sample. We show that with a suitable set-up, the steady state method enables us to measure a very low permeability of 0.8 nD (8 × 10-22 m2) over a period of three days and 2.6 nD (2.6 × 10-21 m2) over a period of one day. While the pulse decay test provides only an average estimate of the permeability for a comparable duration. Many issues are raised in pulse decay tests: determination of the reservoirs storage factor, micro leakage effects, determination of the initial pulse pressure, 2D mechanical effect. Contrary to the widespread belief that transient techniques are required to measure very low permeability, we show that direct steady state measurement of water permeability, with suitable equipments, can be much faster and more accurate than measurement by pulse decay. In fact, low water and rock compressibilities result in fast propagation of pressure wave and it cannot be argued that steady state conditions are not reachable in a reasonable amount of time. Still, pulse decay remains an interesting alternative to steady state methods when permeability is higher than 50 nD (5 × 10-20 m2). <br> Les milieux très peu perméables (k < 10 nD (10-20 m2)) comme les argiles sont étudiés dans le cadre de problématiques très diverses telles que le stockage du CO2, les surpressions en forage profond ou le stockage des déchets radioactifs. La caractérisation pétrophysique de ces roches, et notamment la mesure de leur faible perméabilité, est difficile. La technique en laboratoire la plus répandue est celle du pulse decay. Cette technique consiste à imposer un pulse de pression en amont de l’échantillon puis de suivre l’évolution des pressions amont et aval. La durée de l’essai est supérieure à la journée pour des échantillons d’un nanoDarcy. Le signal est fortement tributaire des fuites dans le système ou des variations de température. La méthode stationnaire consiste à mesurer directement le débit d’eau à travers l’échantillon pour un gradient de pression donné. Cette technique est rarement utilisée pour les milieux très peu perméables car réputée très longue (Hsieh et al., 1981, Int. J. Rock Mech. Min. Sci. Geomech. Abstr. 18, 245-252). Des essais en laboratoire ont été réalisés sur trois échantillons. La méthode stationnaire ainsi que des méthodes transitoires (dont le pulse decay) furent employées. La limitation principale des méthodes transitoires est la difficulté d’interpréter correctement les profils de relaxation. La méthode stationnaire s’est montrée aussi rapide (trois jours pour un échantillon de 0.8 nD (8 × 10-22 m2)), voire plus rapide (moins d’une journée pour un échantillon de 2.6 nD (2.6 × 10-21 m2)), que la méthode du pulse decay. La perméabilité a été plus simple à déterminer et cette méthode peut être rapide avec un équipement adapté. En réalité, la faible compressibilité de la roche permet une propagation rapide des ondes de pression. De ce fait, il ne peut pas être soutenu que les conditions de régime permanent ne soient pas atteintes en un temps raisonnable. La méthode pulse decay reste une alternative intéressante à la méthode stationnaire lorsque la perméabilité est supérieure à 50 nD (5 × 10-20 m2).
ISSN:1294-4475