Influence of Load Model to Out-of-step Oscillation Characteristics of Power System

[Introduction] Load, as the part that ultimately consumes active power, has a very important impact on the stability of the system. Therefore, the influence of different load models on out-of-step oscillation characteristics of power system is studied in this paper. [Method] This paper took a large...

Full description

Bibliographic Details
Main Authors: MA Weizhe, CHENG Weijie, ZHANG Shipeng, XU Qin
Format: Article
Language:English
Published: Energy Observer Magazine Co., Ltd. 2021-03-01
Series:南方能源建设
Subjects:
Online Access:https://www.energychina.press/en/article/doi/10.16516/j.gedi.issn2095-8676.2021.01.016
id doaj-189adea548c9454a989abb51a342390a
record_format Article
spelling doaj-189adea548c9454a989abb51a342390a2021-08-20T09:35:37ZengEnergy Observer Magazine Co., Ltd.南方能源建设2095-86762021-03-018111011410.16516/j.gedi.issn2095-8676.2021.01.016Influence of Load Model to Out-of-step Oscillation Characteristics of Power SystemMA Weizhe0CHENG Weijie1ZHANG Shipeng2XU Qin3Shenzhen Power Supply Bureau Co., Ltd., Shenzhen 518000, ChinaShenzhen Power Supply Bureau Co., Ltd., Shenzhen 518000, ChinaChina Energy Engineering Group Guangdong Electric Power Design Institute Co., Ltd., Guangzhou 510663, ChinaChina Energy Engineering Group Guangdong Electric Power Design Institute Co., Ltd., Guangzhou 510663, China[Introduction] Load, as the part that ultimately consumes active power, has a very important impact on the stability of the system. Therefore, the influence of different load models on out-of-step oscillation characteristics of power system is studied in this paper. [Method] This paper took a large grid’s regional discontinuity as the research target to comprehensively analyze the effects of different load models on the oscillation center and action of out of step splitting device using BPA program developed by China Electric Power Research Institute. [Result] The simulation results show when using the ZIP static load model, the line Ucos curve demonstrates the best periodic integrity, as the proportion of induction motor type load increases, the Ucos curve’s periodic integrity becomes worse, it even leads to a subversive change in the conclusion whether the out of step splitting device can react. In addition, different load models also cause the oscillation center migration. [Conclusion] Therefore, the credibility of simulation results can only be guaranteed by using the most realistic load model.https://www.energychina.press/en/article/doi/10.16516/j.gedi.issn2095-8676.2021.01.016load modelout-of-step oscillationoscillation centerout of step splitting device
collection DOAJ
language English
format Article
sources DOAJ
author MA Weizhe
CHENG Weijie
ZHANG Shipeng
XU Qin
spellingShingle MA Weizhe
CHENG Weijie
ZHANG Shipeng
XU Qin
Influence of Load Model to Out-of-step Oscillation Characteristics of Power System
南方能源建设
load model
out-of-step oscillation
oscillation center
out of step splitting device
author_facet MA Weizhe
CHENG Weijie
ZHANG Shipeng
XU Qin
author_sort MA Weizhe
title Influence of Load Model to Out-of-step Oscillation Characteristics of Power System
title_short Influence of Load Model to Out-of-step Oscillation Characteristics of Power System
title_full Influence of Load Model to Out-of-step Oscillation Characteristics of Power System
title_fullStr Influence of Load Model to Out-of-step Oscillation Characteristics of Power System
title_full_unstemmed Influence of Load Model to Out-of-step Oscillation Characteristics of Power System
title_sort influence of load model to out-of-step oscillation characteristics of power system
publisher Energy Observer Magazine Co., Ltd.
series 南方能源建设
issn 2095-8676
publishDate 2021-03-01
description [Introduction] Load, as the part that ultimately consumes active power, has a very important impact on the stability of the system. Therefore, the influence of different load models on out-of-step oscillation characteristics of power system is studied in this paper. [Method] This paper took a large grid’s regional discontinuity as the research target to comprehensively analyze the effects of different load models on the oscillation center and action of out of step splitting device using BPA program developed by China Electric Power Research Institute. [Result] The simulation results show when using the ZIP static load model, the line Ucos curve demonstrates the best periodic integrity, as the proportion of induction motor type load increases, the Ucos curve’s periodic integrity becomes worse, it even leads to a subversive change in the conclusion whether the out of step splitting device can react. In addition, different load models also cause the oscillation center migration. [Conclusion] Therefore, the credibility of simulation results can only be guaranteed by using the most realistic load model.
topic load model
out-of-step oscillation
oscillation center
out of step splitting device
url https://www.energychina.press/en/article/doi/10.16516/j.gedi.issn2095-8676.2021.01.016
work_keys_str_mv AT maweizhe influenceofloadmodeltooutofsteposcillationcharacteristicsofpowersystem
AT chengweijie influenceofloadmodeltooutofsteposcillationcharacteristicsofpowersystem
AT zhangshipeng influenceofloadmodeltooutofsteposcillationcharacteristicsofpowersystem
AT xuqin influenceofloadmodeltooutofsteposcillationcharacteristicsofpowersystem
_version_ 1721201258352607232