Optimal Siting and Sizing of Multiple DG Units for the Enhancement of Voltage Profile and Loss Minimization in Transmission Systems Using Nature Inspired Algorithms

Power grid becomes smarter nowadays along with technological development. The benefits of smart grid can be enhanced through the integration of renewable energy sources. In this paper, several studies have been made to reconfigure a conventional network into a smart grid. Amongst all the renewable s...

Full description

Bibliographic Details
Main Authors: Ambika Ramamoorthy, Rajeswari Ramachandran
Format: Article
Language:English
Published: Hindawi Limited 2016-01-01
Series:The Scientific World Journal
Online Access:http://dx.doi.org/10.1155/2016/1086579
id doaj-1898bfbf217b465ca4ab03b9fd26ad1d
record_format Article
spelling doaj-1898bfbf217b465ca4ab03b9fd26ad1d2020-11-25T01:53:45ZengHindawi LimitedThe Scientific World Journal2356-61401537-744X2016-01-01201610.1155/2016/10865791086579Optimal Siting and Sizing of Multiple DG Units for the Enhancement of Voltage Profile and Loss Minimization in Transmission Systems Using Nature Inspired AlgorithmsAmbika Ramamoorthy0Rajeswari Ramachandran1Department of Electrical Engineering, Anna University, Chennai, Tamil Nadu 600 025, IndiaDepartment of Electrical Engineering, Government College of Technology, Coimbatore, Tamil Nadu 641 041, IndiaPower grid becomes smarter nowadays along with technological development. The benefits of smart grid can be enhanced through the integration of renewable energy sources. In this paper, several studies have been made to reconfigure a conventional network into a smart grid. Amongst all the renewable sources, solar power takes the prominent position due to its availability in abundance. Proposed methodology presented in this paper is aimed at minimizing network power losses and at improving the voltage stability within the frame work of system operation and security constraints in a transmission system. Locations and capacities of DGs have a significant impact on the system losses in a transmission system. In this paper, combined nature inspired algorithms are presented for optimal location and sizing of DGs. This paper proposes a two-step optimization technique in order to integrate DG. In a first step, the best size of DG is determined through PSO metaheuristics and the results obtained through PSO is tested for reverse power flow by negative load approach to find possible bus locations. Then, optimal location is found by Loss Sensitivity Factor (LSF) and weak (WK) bus methods and the results are compared. In a second step, optimal sizing of DGs is determined by PSO, GSA, and hybrid PSOGSA algorithms. Apart from optimal sizing and siting of DGs, different scenarios with number of DGs (3, 4, and 5) and PQ capacities of DGs (P alone, Q alone, and  P and Q both) are also analyzed and the results are analyzed in this paper. A detailed performance analysis is carried out on IEEE 30-bus system to demonstrate the effectiveness of the proposed methodology.http://dx.doi.org/10.1155/2016/1086579
collection DOAJ
language English
format Article
sources DOAJ
author Ambika Ramamoorthy
Rajeswari Ramachandran
spellingShingle Ambika Ramamoorthy
Rajeswari Ramachandran
Optimal Siting and Sizing of Multiple DG Units for the Enhancement of Voltage Profile and Loss Minimization in Transmission Systems Using Nature Inspired Algorithms
The Scientific World Journal
author_facet Ambika Ramamoorthy
Rajeswari Ramachandran
author_sort Ambika Ramamoorthy
title Optimal Siting and Sizing of Multiple DG Units for the Enhancement of Voltage Profile and Loss Minimization in Transmission Systems Using Nature Inspired Algorithms
title_short Optimal Siting and Sizing of Multiple DG Units for the Enhancement of Voltage Profile and Loss Minimization in Transmission Systems Using Nature Inspired Algorithms
title_full Optimal Siting and Sizing of Multiple DG Units for the Enhancement of Voltage Profile and Loss Minimization in Transmission Systems Using Nature Inspired Algorithms
title_fullStr Optimal Siting and Sizing of Multiple DG Units for the Enhancement of Voltage Profile and Loss Minimization in Transmission Systems Using Nature Inspired Algorithms
title_full_unstemmed Optimal Siting and Sizing of Multiple DG Units for the Enhancement of Voltage Profile and Loss Minimization in Transmission Systems Using Nature Inspired Algorithms
title_sort optimal siting and sizing of multiple dg units for the enhancement of voltage profile and loss minimization in transmission systems using nature inspired algorithms
publisher Hindawi Limited
series The Scientific World Journal
issn 2356-6140
1537-744X
publishDate 2016-01-01
description Power grid becomes smarter nowadays along with technological development. The benefits of smart grid can be enhanced through the integration of renewable energy sources. In this paper, several studies have been made to reconfigure a conventional network into a smart grid. Amongst all the renewable sources, solar power takes the prominent position due to its availability in abundance. Proposed methodology presented in this paper is aimed at minimizing network power losses and at improving the voltage stability within the frame work of system operation and security constraints in a transmission system. Locations and capacities of DGs have a significant impact on the system losses in a transmission system. In this paper, combined nature inspired algorithms are presented for optimal location and sizing of DGs. This paper proposes a two-step optimization technique in order to integrate DG. In a first step, the best size of DG is determined through PSO metaheuristics and the results obtained through PSO is tested for reverse power flow by negative load approach to find possible bus locations. Then, optimal location is found by Loss Sensitivity Factor (LSF) and weak (WK) bus methods and the results are compared. In a second step, optimal sizing of DGs is determined by PSO, GSA, and hybrid PSOGSA algorithms. Apart from optimal sizing and siting of DGs, different scenarios with number of DGs (3, 4, and 5) and PQ capacities of DGs (P alone, Q alone, and  P and Q both) are also analyzed and the results are analyzed in this paper. A detailed performance analysis is carried out on IEEE 30-bus system to demonstrate the effectiveness of the proposed methodology.
url http://dx.doi.org/10.1155/2016/1086579
work_keys_str_mv AT ambikaramamoorthy optimalsitingandsizingofmultipledgunitsfortheenhancementofvoltageprofileandlossminimizationintransmissionsystemsusingnatureinspiredalgorithms
AT rajeswariramachandran optimalsitingandsizingofmultipledgunitsfortheenhancementofvoltageprofileandlossminimizationintransmissionsystemsusingnatureinspiredalgorithms
_version_ 1724989252080500736