A Method to Justify Process Control Systems in Mineral Processing Applications
The impact of installing process control systems can be expected in terms of performance improvements through reduced operating costs. Since these installations impose considerable capital expenditure, the profitability of the new systems should be economically justified. Controlled variable trend...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Iranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECR
2013-12-01
|
Series: | Iranian Journal of Chemistry & Chemical Engineering |
Subjects: | |
Online Access: | http://www.ijcce.ac.ir/article_6750_78730e1e3fc7381b9bccd4b18f15a4ac.pdf |
id |
doaj-18493f100b104cdba627327650222590 |
---|---|
record_format |
Article |
spelling |
doaj-18493f100b104cdba6273276502225902020-11-25T03:40:33ZengIranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECRIranian Journal of Chemistry & Chemical Engineering 1021-99861021-99862013-12-013241051156750A Method to Justify Process Control Systems in Mineral Processing ApplicationsGholamabbas Parsapour0Mostafa Maleki1Samad Banisi2Mining Engineering Goup, Shahid Bahonar University of Kerman, P.O. Box 76175-133 Kerman, I.R. IRANMining Engineering Group, ValiAsr University of Rafsanjan, P.O. Box 518 Rafsanjan, I.R. IRANMining Engineering Goup, Shahid Bahonar University of Kerman, P.O. Box 76175-133 Kerman, I.R. IRANThe impact of installing process control systems can be expected in terms of performance improvements through reduced operating costs. Since these installations impose considerable capital expenditure, the profitability of the new systems should be economically justified. Controlled variable trend was reconstructed by a combination of simple waves, which provided a means to simulate the effect of installing a control system (feedback) by removing disturbance waves with high periods (> one cycle per hour). A method was proposed to evaluate the impact of installing a control system either by a reduction of difference between concentrate target quality and operating quality (i.e., bias reduction) or by reduction of scatter of product quality (i.e., variance reduction). Installing automatic control systems not only reduces operating costs, but also may increase revenue from washed coal sales by maintaining plant performance on designed or desired target. It was found that if an appropriate feedback control system is used at the flotation circuit of the Zarand coal washing plant, the variance of concentrate ash content could be decreased from the current value of 0.38 to 0.06. based on the predicted metallurgical improvement, the payback time of installing a conventional control system for the flotation circuit of the Zarand plant size with the approximate cost of $1,000,000 was found to be 2 years.The impact of installing process control systems can be expected in terms of performance improvements through reduced operating costs. Since these installations impose considerable capital expenditure, the profitability of the new systems should be economically justified. Controlled variable trend was reconstructed by a combination of simple waves, which provided a means to simulate the effect of installing a control system (feedback) by removing disturbance waves with high periods (> one cycle per hour). A method was proposed to evaluate the impact of installing a control system either by a reduction of difference between concentrate target quality and operating quality (i.e., bias reduction) or by reduction of scatter of product quality (i.e., variance reduction). Installing automatic control systems not only reduces operating costs, but also may increase revenue from washed coal sales by maintaining plant performance on designed or desired target. It was found that if an appropriate feedback control system is used at the flotation circuit of the Zarand coal washing plant, the variance of concentrate ash content could be decreased from the current value of 0.38 to 0.06. based on the predicted metallurgical improvement, the payback time of installing a conventional control system for the flotation circuit of the Zarand plant size with the approximate cost of $1,000,000 was found to be 2 years.http://www.ijcce.ac.ir/article_6750_78730e1e3fc7381b9bccd4b18f15a4ac.pdfcontrol systemjustificationzarand coal washing plant |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Gholamabbas Parsapour Mostafa Maleki Samad Banisi |
spellingShingle |
Gholamabbas Parsapour Mostafa Maleki Samad Banisi A Method to Justify Process Control Systems in Mineral Processing Applications Iranian Journal of Chemistry & Chemical Engineering control system justification zarand coal washing plant |
author_facet |
Gholamabbas Parsapour Mostafa Maleki Samad Banisi |
author_sort |
Gholamabbas Parsapour |
title |
A Method to Justify Process Control Systems in Mineral Processing Applications |
title_short |
A Method to Justify Process Control Systems in Mineral Processing Applications |
title_full |
A Method to Justify Process Control Systems in Mineral Processing Applications |
title_fullStr |
A Method to Justify Process Control Systems in Mineral Processing Applications |
title_full_unstemmed |
A Method to Justify Process Control Systems in Mineral Processing Applications |
title_sort |
method to justify process control systems in mineral processing applications |
publisher |
Iranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECR |
series |
Iranian Journal of Chemistry & Chemical Engineering |
issn |
1021-9986 1021-9986 |
publishDate |
2013-12-01 |
description |
The impact of installing process control systems can be expected in terms of performance improvements through reduced operating costs. Since these installations impose considerable capital expenditure, the profitability of the new systems should be economically justified. Controlled variable trend was reconstructed by a combination of simple waves, which provided a means to simulate the effect of installing a control system (feedback) by removing disturbance waves with high periods (> one cycle per hour). A method was proposed to evaluate the impact of installing a control system either by a reduction of difference between concentrate target quality and operating quality (i.e., bias reduction) or by reduction of scatter of product quality (i.e., variance reduction). Installing automatic control systems not only reduces operating costs, but also may increase revenue from washed coal sales by maintaining plant performance on designed or desired target. It was found that if an appropriate feedback control system is used at the flotation circuit of the Zarand coal washing plant, the variance of concentrate ash content could be decreased from the current value of 0.38 to 0.06. based on the predicted metallurgical improvement, the payback time of installing a conventional control system for the flotation circuit of the Zarand plant size with the approximate cost of $1,000,000 was found to be 2 years.The impact of installing process control systems can be expected in terms of performance improvements through reduced operating costs. Since these installations impose considerable capital expenditure, the profitability of the new systems should be economically justified. Controlled variable trend was reconstructed by a combination of simple waves, which provided a means to simulate the effect of installing a control system (feedback) by removing disturbance waves with high periods (> one cycle per hour). A method was proposed to evaluate the impact of installing a control system either by a reduction of difference between concentrate target quality and operating quality (i.e., bias reduction) or by reduction of scatter of product quality (i.e., variance reduction). Installing automatic control systems not only reduces operating costs, but also may increase revenue from washed coal sales by maintaining plant performance on designed or desired target. It was found that if an appropriate feedback control system is used at the flotation circuit of the Zarand coal washing plant, the variance of concentrate ash content could be decreased from the current value of 0.38 to 0.06. based on the predicted metallurgical improvement, the payback time of installing a conventional control system for the flotation circuit of the Zarand plant size with the approximate cost of $1,000,000 was found to be 2 years. |
topic |
control system justification zarand coal washing plant |
url |
http://www.ijcce.ac.ir/article_6750_78730e1e3fc7381b9bccd4b18f15a4ac.pdf |
work_keys_str_mv |
AT gholamabbasparsapour amethodtojustifyprocesscontrolsystemsinmineralprocessingapplications AT mostafamaleki amethodtojustifyprocesscontrolsystemsinmineralprocessingapplications AT samadbanisi amethodtojustifyprocesscontrolsystemsinmineralprocessingapplications AT gholamabbasparsapour methodtojustifyprocesscontrolsystemsinmineralprocessingapplications AT mostafamaleki methodtojustifyprocesscontrolsystemsinmineralprocessingapplications AT samadbanisi methodtojustifyprocesscontrolsystemsinmineralprocessingapplications |