A Method to Justify Process Control Systems in Mineral Processing Applications

The impact of installing process control systems can be expected in terms of performance improvements through reduced operating costs.  Since these installations impose considerable capital expenditure, the profitability of the new systems should be economically justified. Controlled variable trend...

Full description

Bibliographic Details
Main Authors: Gholamabbas Parsapour, Mostafa Maleki, Samad Banisi
Format: Article
Language:English
Published: Iranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECR 2013-12-01
Series:Iranian Journal of Chemistry & Chemical Engineering
Subjects:
Online Access:http://www.ijcce.ac.ir/article_6750_78730e1e3fc7381b9bccd4b18f15a4ac.pdf
id doaj-18493f100b104cdba627327650222590
record_format Article
spelling doaj-18493f100b104cdba6273276502225902020-11-25T03:40:33ZengIranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECRIranian Journal of Chemistry & Chemical Engineering 1021-99861021-99862013-12-013241051156750A Method to Justify Process Control Systems in Mineral Processing ApplicationsGholamabbas Parsapour0Mostafa Maleki1Samad Banisi2Mining Engineering Goup, Shahid Bahonar University of Kerman, P.O. Box 76175-133 Kerman, I.R. IRANMining Engineering Group, ValiAsr University of Rafsanjan, P.O. Box 518 Rafsanjan, I.R. IRANMining Engineering Goup, Shahid Bahonar University of Kerman, P.O. Box 76175-133 Kerman, I.R. IRANThe impact of installing process control systems can be expected in terms of performance improvements through reduced operating costs.  Since these installations impose considerable capital expenditure, the profitability of the new systems should be economically justified. Controlled variable trend was reconstructed by a combination of simple waves, which provided a means to simulate the effect of installing a control system (feedback) by removing disturbance waves with high periods (> one cycle per hour).  A method was proposed to evaluate the impact of installing a control system either by a reduction of difference between concentrate target quality and operating quality (i.e., bias reduction) or by reduction of scatter of product quality (i.e., variance reduction).  Installing automatic control systems not only reduces operating costs, but also may increase revenue from washed coal sales by maintaining plant performance on designed or desired target. It was found that if an appropriate feedback control system is used at the flotation circuit of the Zarand coal washing plant, the variance of concentrate ash content could be decreased from the current value of 0.38 to 0.06. based on the predicted metallurgical improvement, the payback time of installing a conventional control system for the flotation circuit of the Zarand plant size with the approximate cost of $1,000,000 was found to be 2 years.The impact of installing process control systems can be expected in terms of performance improvements through reduced operating costs.  Since these installations impose considerable capital expenditure, the profitability of the new systems should be economically justified. Controlled variable trend was reconstructed by a combination of simple waves, which provided a means to simulate the effect of installing a control system (feedback) by removing disturbance waves with high periods (> one cycle per hour).  A method was proposed to evaluate the impact of installing a control system either by a reduction of difference between concentrate target quality and operating quality (i.e., bias reduction) or by reduction of scatter of product quality (i.e., variance reduction).  Installing automatic control systems not only reduces operating costs, but also may increase revenue from washed coal sales by maintaining plant performance on designed or desired target. It was found that if an appropriate feedback control system is used at the flotation circuit of the Zarand coal washing plant, the variance of concentrate ash content could be decreased from the current value of 0.38 to 0.06. based on the predicted metallurgical improvement, the payback time of installing a conventional control system for the flotation circuit of the Zarand plant size with the approximate cost of $1,000,000 was found to be 2 years.http://www.ijcce.ac.ir/article_6750_78730e1e3fc7381b9bccd4b18f15a4ac.pdfcontrol systemjustificationzarand coal washing plant
collection DOAJ
language English
format Article
sources DOAJ
author Gholamabbas Parsapour
Mostafa Maleki
Samad Banisi
spellingShingle Gholamabbas Parsapour
Mostafa Maleki
Samad Banisi
A Method to Justify Process Control Systems in Mineral Processing Applications
Iranian Journal of Chemistry & Chemical Engineering
control system
justification
zarand coal washing plant
author_facet Gholamabbas Parsapour
Mostafa Maleki
Samad Banisi
author_sort Gholamabbas Parsapour
title A Method to Justify Process Control Systems in Mineral Processing Applications
title_short A Method to Justify Process Control Systems in Mineral Processing Applications
title_full A Method to Justify Process Control Systems in Mineral Processing Applications
title_fullStr A Method to Justify Process Control Systems in Mineral Processing Applications
title_full_unstemmed A Method to Justify Process Control Systems in Mineral Processing Applications
title_sort method to justify process control systems in mineral processing applications
publisher Iranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECR
series Iranian Journal of Chemistry & Chemical Engineering
issn 1021-9986
1021-9986
publishDate 2013-12-01
description The impact of installing process control systems can be expected in terms of performance improvements through reduced operating costs.  Since these installations impose considerable capital expenditure, the profitability of the new systems should be economically justified. Controlled variable trend was reconstructed by a combination of simple waves, which provided a means to simulate the effect of installing a control system (feedback) by removing disturbance waves with high periods (> one cycle per hour).  A method was proposed to evaluate the impact of installing a control system either by a reduction of difference between concentrate target quality and operating quality (i.e., bias reduction) or by reduction of scatter of product quality (i.e., variance reduction).  Installing automatic control systems not only reduces operating costs, but also may increase revenue from washed coal sales by maintaining plant performance on designed or desired target. It was found that if an appropriate feedback control system is used at the flotation circuit of the Zarand coal washing plant, the variance of concentrate ash content could be decreased from the current value of 0.38 to 0.06. based on the predicted metallurgical improvement, the payback time of installing a conventional control system for the flotation circuit of the Zarand plant size with the approximate cost of $1,000,000 was found to be 2 years.The impact of installing process control systems can be expected in terms of performance improvements through reduced operating costs.  Since these installations impose considerable capital expenditure, the profitability of the new systems should be economically justified. Controlled variable trend was reconstructed by a combination of simple waves, which provided a means to simulate the effect of installing a control system (feedback) by removing disturbance waves with high periods (> one cycle per hour).  A method was proposed to evaluate the impact of installing a control system either by a reduction of difference between concentrate target quality and operating quality (i.e., bias reduction) or by reduction of scatter of product quality (i.e., variance reduction).  Installing automatic control systems not only reduces operating costs, but also may increase revenue from washed coal sales by maintaining plant performance on designed or desired target. It was found that if an appropriate feedback control system is used at the flotation circuit of the Zarand coal washing plant, the variance of concentrate ash content could be decreased from the current value of 0.38 to 0.06. based on the predicted metallurgical improvement, the payback time of installing a conventional control system for the flotation circuit of the Zarand plant size with the approximate cost of $1,000,000 was found to be 2 years.
topic control system
justification
zarand coal washing plant
url http://www.ijcce.ac.ir/article_6750_78730e1e3fc7381b9bccd4b18f15a4ac.pdf
work_keys_str_mv AT gholamabbasparsapour amethodtojustifyprocesscontrolsystemsinmineralprocessingapplications
AT mostafamaleki amethodtojustifyprocesscontrolsystemsinmineralprocessingapplications
AT samadbanisi amethodtojustifyprocesscontrolsystemsinmineralprocessingapplications
AT gholamabbasparsapour methodtojustifyprocesscontrolsystemsinmineralprocessingapplications
AT mostafamaleki methodtojustifyprocesscontrolsystemsinmineralprocessingapplications
AT samadbanisi methodtojustifyprocesscontrolsystemsinmineralprocessingapplications
_version_ 1724534104553160704