Fast-type high-accuracy universal polarimeter using charge-coupled device spectrometer

A fast, high-accuracy universal polarimeter was developed using a charge-coupled device (CCD) spectrometer (CCD-HAUP), to carry out simultaneous optical anisotropic (linear birefringence, LB; linear dichroism, LD) and chiroptical (circular birefringence, CB; circular dichroism, CD) measurements on s...

Full description

Bibliographic Details
Main Authors: Akifumi Takanabe, Hideko Koshima, Toru Asahi
Format: Article
Language:English
Published: AIP Publishing LLC 2017-02-01
Series:AIP Advances
Online Access:http://dx.doi.org/10.1063/1.4977440
id doaj-17eff442c80843c3b7587714ec0b3b9b
record_format Article
spelling doaj-17eff442c80843c3b7587714ec0b3b9b2020-11-25T00:00:50ZengAIP Publishing LLCAIP Advances2158-32262017-02-0172025209025209-1410.1063/1.4977440043702ADVFast-type high-accuracy universal polarimeter using charge-coupled device spectrometerAkifumi Takanabe0Hideko Koshima1Toru Asahi2Department of Advanced Science and Engineering, Graduate School of Advanced Science and Engineering, Waseda University, 3-4-1 Okubo, Shinjuku-ku, Tokyo 169-8555, JapanResearh Organization for Nano & Life Innovation, Waseda University, 513 Wasedatsurumaki-cho, Shinjuku-ku, Tokyo 162-0041, JapanDepartment of Advanced Science and Engineering, Graduate School of Advanced Science and Engineering, Waseda University, 3-4-1 Okubo, Shinjuku-ku, Tokyo 169-8555, JapanA fast, high-accuracy universal polarimeter was developed using a charge-coupled device (CCD) spectrometer (CCD-HAUP), to carry out simultaneous optical anisotropic (linear birefringence, LB; linear dichroism, LD) and chiroptical (circular birefringence, CB; circular dichroism, CD) measurements on single crystals without any pretreatment, in the visible region between 400–680 nm. The principle of the HAUP method is to measure the intensities of emergent light passing through a polarizer, a crystal sample, and then an analyzer, as the azimuth angles of the polarizer and analyzer are independently altered. The CCD-HAUP has the unique feature that white transmitted light intensity can be measured using a CCD spectrometer, compared with the generalized HAUP (G-HAUP) system in which monochromatic transmitted light is measured using a photomultiplier. The CCD-HAUP measurements across the entire wavelength region are completed within the G-HAUP measurement time for a single wavelength. The CCD-HAUP drastically reduces the measurement time for a dataset to only 1.5 h, from the 24 h required for the G-HAUP system. LB, LD, CB, and CD measurements of single crystals of α-quartz and enantiomeric photomechanical salicylidenephenylethylamines before, during, and after ultraviolet light irradiation show results comparable to those obtained using the G-HAUP system. The newly developed system is very effective for samples susceptible to degradation induced by external stimuli, such as light and heat.http://dx.doi.org/10.1063/1.4977440
collection DOAJ
language English
format Article
sources DOAJ
author Akifumi Takanabe
Hideko Koshima
Toru Asahi
spellingShingle Akifumi Takanabe
Hideko Koshima
Toru Asahi
Fast-type high-accuracy universal polarimeter using charge-coupled device spectrometer
AIP Advances
author_facet Akifumi Takanabe
Hideko Koshima
Toru Asahi
author_sort Akifumi Takanabe
title Fast-type high-accuracy universal polarimeter using charge-coupled device spectrometer
title_short Fast-type high-accuracy universal polarimeter using charge-coupled device spectrometer
title_full Fast-type high-accuracy universal polarimeter using charge-coupled device spectrometer
title_fullStr Fast-type high-accuracy universal polarimeter using charge-coupled device spectrometer
title_full_unstemmed Fast-type high-accuracy universal polarimeter using charge-coupled device spectrometer
title_sort fast-type high-accuracy universal polarimeter using charge-coupled device spectrometer
publisher AIP Publishing LLC
series AIP Advances
issn 2158-3226
publishDate 2017-02-01
description A fast, high-accuracy universal polarimeter was developed using a charge-coupled device (CCD) spectrometer (CCD-HAUP), to carry out simultaneous optical anisotropic (linear birefringence, LB; linear dichroism, LD) and chiroptical (circular birefringence, CB; circular dichroism, CD) measurements on single crystals without any pretreatment, in the visible region between 400–680 nm. The principle of the HAUP method is to measure the intensities of emergent light passing through a polarizer, a crystal sample, and then an analyzer, as the azimuth angles of the polarizer and analyzer are independently altered. The CCD-HAUP has the unique feature that white transmitted light intensity can be measured using a CCD spectrometer, compared with the generalized HAUP (G-HAUP) system in which monochromatic transmitted light is measured using a photomultiplier. The CCD-HAUP measurements across the entire wavelength region are completed within the G-HAUP measurement time for a single wavelength. The CCD-HAUP drastically reduces the measurement time for a dataset to only 1.5 h, from the 24 h required for the G-HAUP system. LB, LD, CB, and CD measurements of single crystals of α-quartz and enantiomeric photomechanical salicylidenephenylethylamines before, during, and after ultraviolet light irradiation show results comparable to those obtained using the G-HAUP system. The newly developed system is very effective for samples susceptible to degradation induced by external stimuli, such as light and heat.
url http://dx.doi.org/10.1063/1.4977440
work_keys_str_mv AT akifumitakanabe fasttypehighaccuracyuniversalpolarimeterusingchargecoupleddevicespectrometer
AT hidekokoshima fasttypehighaccuracyuniversalpolarimeterusingchargecoupleddevicespectrometer
AT toruasahi fasttypehighaccuracyuniversalpolarimeterusingchargecoupleddevicespectrometer
_version_ 1725443150436106240