Dose Area Product Performance in Fluoroscopy as Supporting Modalities Lithrotripsi Extracorporeal Shock Wave (ESWL) Action for Kidney Stone Localization Resolution

This is an observational method with a quantitative approach to study the magnitude of dose area product who received ESWL patients and the level of safety in accordance with the rules of radiation safety in the use of X-ray. Processing and analysis of the data is done by calculating the dose area p...

Full description

Bibliographic Details
Main Authors: Siti Daryati, M. Irwan Katili, Sri Mulyati
Format: Article
Language:Indonesian
Published: UPPM, Poltekkes Kemenkes Semarang 2015-08-01
Series:Jurnal Riset Kesehatan
Subjects:
Online Access:http://ejournal.poltekkes-smg.ac.id/ojs/index.php/jrk/article/view/220
id doaj-17d36af35cf14e82a8cc9184b8efd3e6
record_format Article
spelling doaj-17d36af35cf14e82a8cc9184b8efd3e62020-11-25T01:05:15ZindUPPM, Poltekkes Kemenkes SemarangJurnal Riset Kesehatan2252-50682461-10262015-08-013254054510.31983/jrk.v3i2.220191Dose Area Product Performance in Fluoroscopy as Supporting Modalities Lithrotripsi Extracorporeal Shock Wave (ESWL) Action for Kidney Stone Localization ResolutionSiti Daryati0M. Irwan Katili1Sri Mulyati2Technic of Radiodiagnostic and Radiotherapy Department, Polytechnic Health Ministry of SemarangTechnic of Radiodiagnostic and Radiotherapy Department, Polytechnic Health Ministry of SemarangTechnic of Radiodiagnostic and Radiotherapy Department, Polytechnic Health Ministry of SemarangThis is an observational method with a quantitative approach to study the magnitude of dose area product who received ESWL patients and the level of safety in accordance with the rules of radiation safety in the use of X-ray. Processing and analysis of the data is done by calculating the dose area product ( DAP ) received by the patients at each exposure based on the thickness of the patients were detected with the TLD. Comparison is done with the use of standard flouroscopy examination. Result shows that 10 cm material thickness in 0.008 minutes results 187mGy.cm2 and 5095 mGy.cm2 DAP in 5 minutes. While in 20 cm phantom thickness and in 0.008 minutes result 424 mGy.cm2 and DAP obtained in 5 minutes is 2 20912 mGy.cm. The use of fluoroscopy on ESWL in Dr . Kariadi hospital is still within the safe limits: < 100 mGy / min , the dose rate exposure on a 10 cm phantom thickness is 3.38 mGy / min and in 20 cm phantom thickness is 13.89 mGy / min , exposure dose rate per minute on the phantom thickness of the 23 cm is 17.03 mGy / min and the rate of patient exposure dose obtained by the observation of 17.61 mGy / min.http://ejournal.poltekkes-smg.ac.id/ojs/index.php/jrk/article/view/220Dose Area ProductfluoroscopyESWL
collection DOAJ
language Indonesian
format Article
sources DOAJ
author Siti Daryati
M. Irwan Katili
Sri Mulyati
spellingShingle Siti Daryati
M. Irwan Katili
Sri Mulyati
Dose Area Product Performance in Fluoroscopy as Supporting Modalities Lithrotripsi Extracorporeal Shock Wave (ESWL) Action for Kidney Stone Localization Resolution
Jurnal Riset Kesehatan
Dose Area Product
fluoroscopy
ESWL
author_facet Siti Daryati
M. Irwan Katili
Sri Mulyati
author_sort Siti Daryati
title Dose Area Product Performance in Fluoroscopy as Supporting Modalities Lithrotripsi Extracorporeal Shock Wave (ESWL) Action for Kidney Stone Localization Resolution
title_short Dose Area Product Performance in Fluoroscopy as Supporting Modalities Lithrotripsi Extracorporeal Shock Wave (ESWL) Action for Kidney Stone Localization Resolution
title_full Dose Area Product Performance in Fluoroscopy as Supporting Modalities Lithrotripsi Extracorporeal Shock Wave (ESWL) Action for Kidney Stone Localization Resolution
title_fullStr Dose Area Product Performance in Fluoroscopy as Supporting Modalities Lithrotripsi Extracorporeal Shock Wave (ESWL) Action for Kidney Stone Localization Resolution
title_full_unstemmed Dose Area Product Performance in Fluoroscopy as Supporting Modalities Lithrotripsi Extracorporeal Shock Wave (ESWL) Action for Kidney Stone Localization Resolution
title_sort dose area product performance in fluoroscopy as supporting modalities lithrotripsi extracorporeal shock wave (eswl) action for kidney stone localization resolution
publisher UPPM, Poltekkes Kemenkes Semarang
series Jurnal Riset Kesehatan
issn 2252-5068
2461-1026
publishDate 2015-08-01
description This is an observational method with a quantitative approach to study the magnitude of dose area product who received ESWL patients and the level of safety in accordance with the rules of radiation safety in the use of X-ray. Processing and analysis of the data is done by calculating the dose area product ( DAP ) received by the patients at each exposure based on the thickness of the patients were detected with the TLD. Comparison is done with the use of standard flouroscopy examination. Result shows that 10 cm material thickness in 0.008 minutes results 187mGy.cm2 and 5095 mGy.cm2 DAP in 5 minutes. While in 20 cm phantom thickness and in 0.008 minutes result 424 mGy.cm2 and DAP obtained in 5 minutes is 2 20912 mGy.cm. The use of fluoroscopy on ESWL in Dr . Kariadi hospital is still within the safe limits: < 100 mGy / min , the dose rate exposure on a 10 cm phantom thickness is 3.38 mGy / min and in 20 cm phantom thickness is 13.89 mGy / min , exposure dose rate per minute on the phantom thickness of the 23 cm is 17.03 mGy / min and the rate of patient exposure dose obtained by the observation of 17.61 mGy / min.
topic Dose Area Product
fluoroscopy
ESWL
url http://ejournal.poltekkes-smg.ac.id/ojs/index.php/jrk/article/view/220
work_keys_str_mv AT sitidaryati doseareaproductperformanceinfluoroscopyassupportingmodalitieslithrotripsiextracorporealshockwaveeswlactionforkidneystonelocalizationresolution
AT mirwankatili doseareaproductperformanceinfluoroscopyassupportingmodalitieslithrotripsiextracorporealshockwaveeswlactionforkidneystonelocalizationresolution
AT srimulyati doseareaproductperformanceinfluoroscopyassupportingmodalitieslithrotripsiextracorporealshockwaveeswlactionforkidneystonelocalizationresolution
_version_ 1725195312001187840