Detection of SARS-CoV-2 RNA by a Multiplex Reverse-Transcription Loop-Mediated Isothermal Amplification Coupled with Melting Curves Analysis
Loop-mediated isothermal amplification (LAMP) is a method of nucleic acid amplification that is more stable and resistant to DNA amplification inhibitors than conventional PCR. LAMP multiplexing with reverse transcription allows for the single-tube amplification of several RNA fragments, including a...
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-05-01
|
Series: | International Journal of Molecular Sciences |
Subjects: | |
Online Access: | https://www.mdpi.com/1422-0067/22/11/5743 |
id |
doaj-171b8b7138b74ea3a1f5a58cf9844fcb |
---|---|
record_format |
Article |
spelling |
doaj-171b8b7138b74ea3a1f5a58cf9844fcb2021-06-01T01:23:31ZengMDPI AGInternational Journal of Molecular Sciences1661-65961422-00672021-05-01225743574310.3390/ijms22115743Detection of SARS-CoV-2 RNA by a Multiplex Reverse-Transcription Loop-Mediated Isothermal Amplification Coupled with Melting Curves AnalysisIgor P. Oscorbin0Georgiy Yu. Shevelev1Ksenia A. Pronyaeva2Andrey A. Stepanov3Darya V. Shamovskaya4Olga V. Mishukova5Dmitrii V. Pyshnyi6Maksim L. Filipenko7Institute of Chemical Biology and Fundamental Medicine, Siberian Branch of the Russian Academy of Sciences (ICBFM SB RAS), 8 Lavrentiev Avenue, 630090 Novosibirsk, RussiaInstitute of Chemical Biology and Fundamental Medicine, Siberian Branch of the Russian Academy of Sciences (ICBFM SB RAS), 8 Lavrentiev Avenue, 630090 Novosibirsk, RussiaInstitute of Chemical Biology and Fundamental Medicine, Siberian Branch of the Russian Academy of Sciences (ICBFM SB RAS), 8 Lavrentiev Avenue, 630090 Novosibirsk, RussiaInstitute of Chemical Biology and Fundamental Medicine, Siberian Branch of the Russian Academy of Sciences (ICBFM SB RAS), 8 Lavrentiev Avenue, 630090 Novosibirsk, RussiaInstitute of Chemical Biology and Fundamental Medicine, Siberian Branch of the Russian Academy of Sciences (ICBFM SB RAS), 8 Lavrentiev Avenue, 630090 Novosibirsk, RussiaInstitute of Chemical Biology and Fundamental Medicine, Siberian Branch of the Russian Academy of Sciences (ICBFM SB RAS), 8 Lavrentiev Avenue, 630090 Novosibirsk, RussiaInstitute of Chemical Biology and Fundamental Medicine, Siberian Branch of the Russian Academy of Sciences (ICBFM SB RAS), 8 Lavrentiev Avenue, 630090 Novosibirsk, RussiaInstitute of Chemical Biology and Fundamental Medicine, Siberian Branch of the Russian Academy of Sciences (ICBFM SB RAS), 8 Lavrentiev Avenue, 630090 Novosibirsk, RussiaLoop-mediated isothermal amplification (LAMP) is a method of nucleic acid amplification that is more stable and resistant to DNA amplification inhibitors than conventional PCR. LAMP multiplexing with reverse transcription allows for the single-tube amplification of several RNA fragments, including an internal control sample, which provides the option of controlling all analytical steps. We developed a method of SARS-CoV-2 viral RNA detection based on multiplex reverse-transcription LAMP, with single-tube qualitative analysis of SARS-CoV-2 RNA and MS2 phage used as a control RNA. The multiplexing is based on the differences in characteristic melting peaks generated during the amplification process. The developed technique detects at least 20 copies of SARS-CoV-2 RNA per reaction on a background of 12,000 MS2 RNA copies. The total time of analysis does not exceed 40 min. The method validation, performed on 125 clinical samples of patients’ nasal swabs, showed a 97.6% concordance rate with the results of real-time (RT)-PCR assays. The developed multiplexed LAMP can be employed as an alternative to PCR in diagnostic practice to save personnel and equipment time.https://www.mdpi.com/1422-0067/22/11/5743SARS-CoV-2coronavirusloop-mediated isothermal amplificationLAMPmultiplex amplificationmelting curve analysis |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Igor P. Oscorbin Georgiy Yu. Shevelev Ksenia A. Pronyaeva Andrey A. Stepanov Darya V. Shamovskaya Olga V. Mishukova Dmitrii V. Pyshnyi Maksim L. Filipenko |
spellingShingle |
Igor P. Oscorbin Georgiy Yu. Shevelev Ksenia A. Pronyaeva Andrey A. Stepanov Darya V. Shamovskaya Olga V. Mishukova Dmitrii V. Pyshnyi Maksim L. Filipenko Detection of SARS-CoV-2 RNA by a Multiplex Reverse-Transcription Loop-Mediated Isothermal Amplification Coupled with Melting Curves Analysis International Journal of Molecular Sciences SARS-CoV-2 coronavirus loop-mediated isothermal amplification LAMP multiplex amplification melting curve analysis |
author_facet |
Igor P. Oscorbin Georgiy Yu. Shevelev Ksenia A. Pronyaeva Andrey A. Stepanov Darya V. Shamovskaya Olga V. Mishukova Dmitrii V. Pyshnyi Maksim L. Filipenko |
author_sort |
Igor P. Oscorbin |
title |
Detection of SARS-CoV-2 RNA by a Multiplex Reverse-Transcription Loop-Mediated Isothermal Amplification Coupled with Melting Curves Analysis |
title_short |
Detection of SARS-CoV-2 RNA by a Multiplex Reverse-Transcription Loop-Mediated Isothermal Amplification Coupled with Melting Curves Analysis |
title_full |
Detection of SARS-CoV-2 RNA by a Multiplex Reverse-Transcription Loop-Mediated Isothermal Amplification Coupled with Melting Curves Analysis |
title_fullStr |
Detection of SARS-CoV-2 RNA by a Multiplex Reverse-Transcription Loop-Mediated Isothermal Amplification Coupled with Melting Curves Analysis |
title_full_unstemmed |
Detection of SARS-CoV-2 RNA by a Multiplex Reverse-Transcription Loop-Mediated Isothermal Amplification Coupled with Melting Curves Analysis |
title_sort |
detection of sars-cov-2 rna by a multiplex reverse-transcription loop-mediated isothermal amplification coupled with melting curves analysis |
publisher |
MDPI AG |
series |
International Journal of Molecular Sciences |
issn |
1661-6596 1422-0067 |
publishDate |
2021-05-01 |
description |
Loop-mediated isothermal amplification (LAMP) is a method of nucleic acid amplification that is more stable and resistant to DNA amplification inhibitors than conventional PCR. LAMP multiplexing with reverse transcription allows for the single-tube amplification of several RNA fragments, including an internal control sample, which provides the option of controlling all analytical steps. We developed a method of SARS-CoV-2 viral RNA detection based on multiplex reverse-transcription LAMP, with single-tube qualitative analysis of SARS-CoV-2 RNA and MS2 phage used as a control RNA. The multiplexing is based on the differences in characteristic melting peaks generated during the amplification process. The developed technique detects at least 20 copies of SARS-CoV-2 RNA per reaction on a background of 12,000 MS2 RNA copies. The total time of analysis does not exceed 40 min. The method validation, performed on 125 clinical samples of patients’ nasal swabs, showed a 97.6% concordance rate with the results of real-time (RT)-PCR assays. The developed multiplexed LAMP can be employed as an alternative to PCR in diagnostic practice to save personnel and equipment time. |
topic |
SARS-CoV-2 coronavirus loop-mediated isothermal amplification LAMP multiplex amplification melting curve analysis |
url |
https://www.mdpi.com/1422-0067/22/11/5743 |
work_keys_str_mv |
AT igorposcorbin detectionofsarscov2rnabyamultiplexreversetranscriptionloopmediatedisothermalamplificationcoupledwithmeltingcurvesanalysis AT georgiyyushevelev detectionofsarscov2rnabyamultiplexreversetranscriptionloopmediatedisothermalamplificationcoupledwithmeltingcurvesanalysis AT kseniaapronyaeva detectionofsarscov2rnabyamultiplexreversetranscriptionloopmediatedisothermalamplificationcoupledwithmeltingcurvesanalysis AT andreyastepanov detectionofsarscov2rnabyamultiplexreversetranscriptionloopmediatedisothermalamplificationcoupledwithmeltingcurvesanalysis AT daryavshamovskaya detectionofsarscov2rnabyamultiplexreversetranscriptionloopmediatedisothermalamplificationcoupledwithmeltingcurvesanalysis AT olgavmishukova detectionofsarscov2rnabyamultiplexreversetranscriptionloopmediatedisothermalamplificationcoupledwithmeltingcurvesanalysis AT dmitriivpyshnyi detectionofsarscov2rnabyamultiplexreversetranscriptionloopmediatedisothermalamplificationcoupledwithmeltingcurvesanalysis AT maksimlfilipenko detectionofsarscov2rnabyamultiplexreversetranscriptionloopmediatedisothermalamplificationcoupledwithmeltingcurvesanalysis |
_version_ |
1721412405942026240 |