Variation in dosimeter calibration factor (Ndw) over a period of 20 years

Long delays in renewal of calibration of secondary standards radiation dosimeters in radiation oncology centers due to the COVID19 pandemic have aroused concerns regarding accuracy in dose delivery to patients. The concerns are mainly due to the uncertainty in the absorbed dose to water calibration...

Full description

Bibliographic Details
Main Authors: Manoj Kumar Semwal, Harishchandra Gupta, Sakshi Singhal, Ashok Kumar, Aruna Kaushik
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2021-01-01
Series:Journal of Medical Physics
Subjects:
Online Access:http://www.jmp.org.in/article.asp?issn=0971-6203;year=2021;volume=46;issue=2;spage=125;epage=127;aulast=Semwal
id doaj-16da6dbfb82146079a6c69cf55619efd
record_format Article
spelling doaj-16da6dbfb82146079a6c69cf55619efd2021-08-20T06:10:23ZengWolters Kluwer Medknow PublicationsJournal of Medical Physics0971-62031998-39132021-01-0146212512710.4103/jmp.JMP_42_21Variation in dosimeter calibration factor (Ndw) over a period of 20 yearsManoj Kumar SemwalHarishchandra GuptaSakshi SinghalAshok KumarAruna KaushikLong delays in renewal of calibration of secondary standards radiation dosimeters in radiation oncology centers due to the COVID19 pandemic have aroused concerns regarding accuracy in dose delivery to patients. The concerns are mainly due to the uncertainty in the absorbed dose to water calibration factor (NDW) over a period of time. In this study, the NDWfactor for two ion chambers, thimble type (Farmer) and parallel plate type (Markus), used in most of the radiotherapy centers, were retrospectively reviewed for 20 years. The calibration on all occasions except once was carried out at the Secondary Standards Dosimetry Laboratory, Bhabha Atomic Research Centre, Mumbai. The change in the NDWfactor over this period was < ±3%. We, therefore, believe that a dosimeter with no history of repairs showed reasonable stability in the NDWfactor over a long period.http://www.jmp.org.in/article.asp?issn=0971-6203;year=2021;volume=46;issue=2;spage=125;epage=127;aulast=Semwalcalibration factorsfarmer chambermarkus chambersecondary standards dosimeter
collection DOAJ
language English
format Article
sources DOAJ
author Manoj Kumar Semwal
Harishchandra Gupta
Sakshi Singhal
Ashok Kumar
Aruna Kaushik
spellingShingle Manoj Kumar Semwal
Harishchandra Gupta
Sakshi Singhal
Ashok Kumar
Aruna Kaushik
Variation in dosimeter calibration factor (Ndw) over a period of 20 years
Journal of Medical Physics
calibration factors
farmer chamber
markus chamber
secondary standards dosimeter
author_facet Manoj Kumar Semwal
Harishchandra Gupta
Sakshi Singhal
Ashok Kumar
Aruna Kaushik
author_sort Manoj Kumar Semwal
title Variation in dosimeter calibration factor (Ndw) over a period of 20 years
title_short Variation in dosimeter calibration factor (Ndw) over a period of 20 years
title_full Variation in dosimeter calibration factor (Ndw) over a period of 20 years
title_fullStr Variation in dosimeter calibration factor (Ndw) over a period of 20 years
title_full_unstemmed Variation in dosimeter calibration factor (Ndw) over a period of 20 years
title_sort variation in dosimeter calibration factor (ndw) over a period of 20 years
publisher Wolters Kluwer Medknow Publications
series Journal of Medical Physics
issn 0971-6203
1998-3913
publishDate 2021-01-01
description Long delays in renewal of calibration of secondary standards radiation dosimeters in radiation oncology centers due to the COVID19 pandemic have aroused concerns regarding accuracy in dose delivery to patients. The concerns are mainly due to the uncertainty in the absorbed dose to water calibration factor (NDW) over a period of time. In this study, the NDWfactor for two ion chambers, thimble type (Farmer) and parallel plate type (Markus), used in most of the radiotherapy centers, were retrospectively reviewed for 20 years. The calibration on all occasions except once was carried out at the Secondary Standards Dosimetry Laboratory, Bhabha Atomic Research Centre, Mumbai. The change in the NDWfactor over this period was < ±3%. We, therefore, believe that a dosimeter with no history of repairs showed reasonable stability in the NDWfactor over a long period.
topic calibration factors
farmer chamber
markus chamber
secondary standards dosimeter
url http://www.jmp.org.in/article.asp?issn=0971-6203;year=2021;volume=46;issue=2;spage=125;epage=127;aulast=Semwal
work_keys_str_mv AT manojkumarsemwal variationindosimetercalibrationfactorndwoveraperiodof20years
AT harishchandragupta variationindosimetercalibrationfactorndwoveraperiodof20years
AT sakshisinghal variationindosimetercalibrationfactorndwoveraperiodof20years
AT ashokkumar variationindosimetercalibrationfactorndwoveraperiodof20years
AT arunakaushik variationindosimetercalibrationfactorndwoveraperiodof20years
_version_ 1721201373371957248