A Novel Fault Line Selection Method Based on Improved Oscillator System of Power Distribution Network

A novel method of fault line selection based on IOS is presented. Firstly, the IOS is established by using math model, which adopted TZSC signal to replace built-in signal of duffing chaotic oscillator by selecting appropriate parameters. Then, each line’s TZSC decomposed by db10 wavelet packet to g...

Full description

Bibliographic Details
Main Authors: Xiaowei Wang, Jie Gao, Xiangxiang Wei, Yaxiao Hou
Format: Article
Language:English
Published: Hindawi Limited 2014-01-01
Series:Mathematical Problems in Engineering
Online Access:http://dx.doi.org/10.1155/2014/901810
id doaj-169f1c8f898d4553aac4b34c3918bf56
record_format Article
spelling doaj-169f1c8f898d4553aac4b34c3918bf562020-11-24T20:41:22ZengHindawi LimitedMathematical Problems in Engineering1024-123X1563-51472014-01-01201410.1155/2014/901810901810A Novel Fault Line Selection Method Based on Improved Oscillator System of Power Distribution NetworkXiaowei Wang0Jie Gao1Xiangxiang Wei2Yaxiao Hou3School of Electrical Engineering and Automation, Henan Polytechnic University, Jiaozuo 454000, ChinaSchool of Electrical Engineering and Automation, Henan Polytechnic University, Jiaozuo 454000, ChinaSchool of Electrical Engineering and Automation, Henan Polytechnic University, Jiaozuo 454000, ChinaSchool of Electrical Engineering and Automation, Henan Polytechnic University, Jiaozuo 454000, ChinaA novel method of fault line selection based on IOS is presented. Firstly, the IOS is established by using math model, which adopted TZSC signal to replace built-in signal of duffing chaotic oscillator by selecting appropriate parameters. Then, each line’s TZSC decomposed by db10 wavelet packet to get CFB with the maximum energy principle, and CFB was solved by IOS. Finally, maximum chaotic distance and average chaotic distance on the phase trajectory are used to judge fault line. Simulation results show that the proposed method can accurately judge fault line and healthy line in strong noisy background. Besides, the nondetection zones of proposed method are elaborated.http://dx.doi.org/10.1155/2014/901810
collection DOAJ
language English
format Article
sources DOAJ
author Xiaowei Wang
Jie Gao
Xiangxiang Wei
Yaxiao Hou
spellingShingle Xiaowei Wang
Jie Gao
Xiangxiang Wei
Yaxiao Hou
A Novel Fault Line Selection Method Based on Improved Oscillator System of Power Distribution Network
Mathematical Problems in Engineering
author_facet Xiaowei Wang
Jie Gao
Xiangxiang Wei
Yaxiao Hou
author_sort Xiaowei Wang
title A Novel Fault Line Selection Method Based on Improved Oscillator System of Power Distribution Network
title_short A Novel Fault Line Selection Method Based on Improved Oscillator System of Power Distribution Network
title_full A Novel Fault Line Selection Method Based on Improved Oscillator System of Power Distribution Network
title_fullStr A Novel Fault Line Selection Method Based on Improved Oscillator System of Power Distribution Network
title_full_unstemmed A Novel Fault Line Selection Method Based on Improved Oscillator System of Power Distribution Network
title_sort novel fault line selection method based on improved oscillator system of power distribution network
publisher Hindawi Limited
series Mathematical Problems in Engineering
issn 1024-123X
1563-5147
publishDate 2014-01-01
description A novel method of fault line selection based on IOS is presented. Firstly, the IOS is established by using math model, which adopted TZSC signal to replace built-in signal of duffing chaotic oscillator by selecting appropriate parameters. Then, each line’s TZSC decomposed by db10 wavelet packet to get CFB with the maximum energy principle, and CFB was solved by IOS. Finally, maximum chaotic distance and average chaotic distance on the phase trajectory are used to judge fault line. Simulation results show that the proposed method can accurately judge fault line and healthy line in strong noisy background. Besides, the nondetection zones of proposed method are elaborated.
url http://dx.doi.org/10.1155/2014/901810
work_keys_str_mv AT xiaoweiwang anovelfaultlineselectionmethodbasedonimprovedoscillatorsystemofpowerdistributionnetwork
AT jiegao anovelfaultlineselectionmethodbasedonimprovedoscillatorsystemofpowerdistributionnetwork
AT xiangxiangwei anovelfaultlineselectionmethodbasedonimprovedoscillatorsystemofpowerdistributionnetwork
AT yaxiaohou anovelfaultlineselectionmethodbasedonimprovedoscillatorsystemofpowerdistributionnetwork
AT xiaoweiwang novelfaultlineselectionmethodbasedonimprovedoscillatorsystemofpowerdistributionnetwork
AT jiegao novelfaultlineselectionmethodbasedonimprovedoscillatorsystemofpowerdistributionnetwork
AT xiangxiangwei novelfaultlineselectionmethodbasedonimprovedoscillatorsystemofpowerdistributionnetwork
AT yaxiaohou novelfaultlineselectionmethodbasedonimprovedoscillatorsystemofpowerdistributionnetwork
_version_ 1716825401861341184