Induction Thermography for Surface Crack Detection and Depth Determination
In the last few years, induction thermography has been established as a non-destructive testing method for localizing surface cracks in metals. The sample to be inspected is heated with a short induced electrical current pulse, and the infrared camera records—during and after the heating pulse—the t...
Main Author: | Beate Oswald-Tranta |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2018-02-01
|
Series: | Applied Sciences |
Subjects: | |
Online Access: | http://www.mdpi.com/2076-3417/8/2/257 |
Similar Items
-
Inductive Thermography as Non-Destructive Testing for Railway Rails
by: Christoph Tuschl, et al.
Published: (2021-01-01) -
Infrared thermography study of the fatigue crack propagation
by: O.A. Plekhov, et al.
Published: (2012-07-01) -
Techniques for Evaluating the Depth of a Crack by Means of Laser Spot Thermography
by: Gabriele Inglese, et al.
Published: (2019-09-01) -
Combined lock-in thermography and heat flow measurements for analysing heat dissipation during fatigue crack propagation
by: J. Bär, et al.
Published: (2015-10-01) -
Characterization Method of Surface Crack Based on Laser Thermography
by: Jiaqi Liu, et al.
Published: (2021-01-01)