Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system
Background In industrial disasters, early detection of problems and crisis management are critical for saving the lives of people and reducing the impact of disasters. Purpose In this study, we design a special gateway system that bridges the gap between different communication protocols and enables...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
SAGE Publishing
2018-09-01
|
Series: | Measurement + Control |
Online Access: | https://doi.org/10.1177/0020294018782087 |
id |
doaj-1628ac049b154ed1b9792aeab3562108 |
---|---|
record_format |
Article |
spelling |
doaj-1628ac049b154ed1b9792aeab35621082020-11-25T03:17:37ZengSAGE PublishingMeasurement + Control0020-29402018-09-015110.1177/0020294018782087Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection systemBeşir Demir0Ahmet Tumay1Mehmet Efe Ozbek2Enver Cavus3Electronics Engineering Department, Gebze Technical University, Gebze, TurkeyTübitak Teydeb, Ankara, TurkeyDepartment of Electrical and Electronics Engineering, Atilim University, Ankara, TurkeyDepartment of Electrical and Electronics Engineering, Ankara Yildirim Beyazit University, Ankara, TurkeyBackground In industrial disasters, early detection of problems and crisis management are critical for saving the lives of people and reducing the impact of disasters. Purpose In this study, we design a special gateway system that bridges the gap between different communication protocols and enables legacy supervisory control and data acquisition systems to function early detection systems for potential industrial disasters. Methods The system uses a new queue mechanism to substantially improve the problem of data loss found in conventional supervisory control and data acquisition systems and utilizes identification (ID) prioritization to enable early detection of problems. The proposed system is implemented and tested on a Linux-based, 3G-capable Modbus gateway system. Modbus is used as the communication protocol and 3G technology is utilized to provide high-speed wireless data transfer components. The Modbus gateway device uses an ARM-based EP9302 processor and has digital input/output, relay outputs, and RS485 outputs. Conclusion This study is significant as it is the first work to show the application of the priority query execution method for Modbus gateway devices.https://doi.org/10.1177/0020294018782087 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Beşir Demir Ahmet Tumay Mehmet Efe Ozbek Enver Cavus |
spellingShingle |
Beşir Demir Ahmet Tumay Mehmet Efe Ozbek Enver Cavus Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system Measurement + Control |
author_facet |
Beşir Demir Ahmet Tumay Mehmet Efe Ozbek Enver Cavus |
author_sort |
Beşir Demir |
title |
Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system |
title_short |
Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system |
title_full |
Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system |
title_fullStr |
Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system |
title_full_unstemmed |
Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system |
title_sort |
design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system |
publisher |
SAGE Publishing |
series |
Measurement + Control |
issn |
0020-2940 |
publishDate |
2018-09-01 |
description |
Background In industrial disasters, early detection of problems and crisis management are critical for saving the lives of people and reducing the impact of disasters. Purpose In this study, we design a special gateway system that bridges the gap between different communication protocols and enables legacy supervisory control and data acquisition systems to function early detection systems for potential industrial disasters. Methods The system uses a new queue mechanism to substantially improve the problem of data loss found in conventional supervisory control and data acquisition systems and utilizes identification (ID) prioritization to enable early detection of problems. The proposed system is implemented and tested on a Linux-based, 3G-capable Modbus gateway system. Modbus is used as the communication protocol and 3G technology is utilized to provide high-speed wireless data transfer components. The Modbus gateway device uses an ARM-based EP9302 processor and has digital input/output, relay outputs, and RS485 outputs. Conclusion This study is significant as it is the first work to show the application of the priority query execution method for Modbus gateway devices. |
url |
https://doi.org/10.1177/0020294018782087 |
work_keys_str_mv |
AT besirdemir designofasystemsolutionthatmodernizeslegacysupervisorycontrolanddataacquisitionsystemsasanearlydetectionsystem AT ahmettumay designofasystemsolutionthatmodernizeslegacysupervisorycontrolanddataacquisitionsystemsasanearlydetectionsystem AT mehmetefeozbek designofasystemsolutionthatmodernizeslegacysupervisorycontrolanddataacquisitionsystemsasanearlydetectionsystem AT envercavus designofasystemsolutionthatmodernizeslegacysupervisorycontrolanddataacquisitionsystemsasanearlydetectionsystem |
_version_ |
1724630974764941312 |