Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system

Background In industrial disasters, early detection of problems and crisis management are critical for saving the lives of people and reducing the impact of disasters. Purpose In this study, we design a special gateway system that bridges the gap between different communication protocols and enables...

Full description

Bibliographic Details
Main Authors: Beşir Demir, Ahmet Tumay, Mehmet Efe Ozbek, Enver Cavus
Format: Article
Language:English
Published: SAGE Publishing 2018-09-01
Series:Measurement + Control
Online Access:https://doi.org/10.1177/0020294018782087
id doaj-1628ac049b154ed1b9792aeab3562108
record_format Article
spelling doaj-1628ac049b154ed1b9792aeab35621082020-11-25T03:17:37ZengSAGE PublishingMeasurement + Control0020-29402018-09-015110.1177/0020294018782087Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection systemBeşir Demir0Ahmet Tumay1Mehmet Efe Ozbek2Enver Cavus3Electronics Engineering Department, Gebze Technical University, Gebze, TurkeyTübitak Teydeb, Ankara, TurkeyDepartment of Electrical and Electronics Engineering, Atilim University, Ankara, TurkeyDepartment of Electrical and Electronics Engineering, Ankara Yildirim Beyazit University, Ankara, TurkeyBackground In industrial disasters, early detection of problems and crisis management are critical for saving the lives of people and reducing the impact of disasters. Purpose In this study, we design a special gateway system that bridges the gap between different communication protocols and enables legacy supervisory control and data acquisition systems to function early detection systems for potential industrial disasters. Methods The system uses a new queue mechanism to substantially improve the problem of data loss found in conventional supervisory control and data acquisition systems and utilizes identification (ID) prioritization to enable early detection of problems. The proposed system is implemented and tested on a Linux-based, 3G-capable Modbus gateway system. Modbus is used as the communication protocol and 3G technology is utilized to provide high-speed wireless data transfer components. The Modbus gateway device uses an ARM-based EP9302 processor and has digital input/output, relay outputs, and RS485 outputs. Conclusion This study is significant as it is the first work to show the application of the priority query execution method for Modbus gateway devices.https://doi.org/10.1177/0020294018782087
collection DOAJ
language English
format Article
sources DOAJ
author Beşir Demir
Ahmet Tumay
Mehmet Efe Ozbek
Enver Cavus
spellingShingle Beşir Demir
Ahmet Tumay
Mehmet Efe Ozbek
Enver Cavus
Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system
Measurement + Control
author_facet Beşir Demir
Ahmet Tumay
Mehmet Efe Ozbek
Enver Cavus
author_sort Beşir Demir
title Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system
title_short Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system
title_full Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system
title_fullStr Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system
title_full_unstemmed Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system
title_sort design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system
publisher SAGE Publishing
series Measurement + Control
issn 0020-2940
publishDate 2018-09-01
description Background In industrial disasters, early detection of problems and crisis management are critical for saving the lives of people and reducing the impact of disasters. Purpose In this study, we design a special gateway system that bridges the gap between different communication protocols and enables legacy supervisory control and data acquisition systems to function early detection systems for potential industrial disasters. Methods The system uses a new queue mechanism to substantially improve the problem of data loss found in conventional supervisory control and data acquisition systems and utilizes identification (ID) prioritization to enable early detection of problems. The proposed system is implemented and tested on a Linux-based, 3G-capable Modbus gateway system. Modbus is used as the communication protocol and 3G technology is utilized to provide high-speed wireless data transfer components. The Modbus gateway device uses an ARM-based EP9302 processor and has digital input/output, relay outputs, and RS485 outputs. Conclusion This study is significant as it is the first work to show the application of the priority query execution method for Modbus gateway devices.
url https://doi.org/10.1177/0020294018782087
work_keys_str_mv AT besirdemir designofasystemsolutionthatmodernizeslegacysupervisorycontrolanddataacquisitionsystemsasanearlydetectionsystem
AT ahmettumay designofasystemsolutionthatmodernizeslegacysupervisorycontrolanddataacquisitionsystemsasanearlydetectionsystem
AT mehmetefeozbek designofasystemsolutionthatmodernizeslegacysupervisorycontrolanddataacquisitionsystemsasanearlydetectionsystem
AT envercavus designofasystemsolutionthatmodernizeslegacysupervisorycontrolanddataacquisitionsystemsasanearlydetectionsystem
_version_ 1724630974764941312