Carrier-Envelope Phase Measurement With Linear Optical Sampling

In the few-cycle pulses, the temporal evolution of the electric field sensitively depends on the carrier-envelope phase (CEP). The ability to measure and stabilize the CEP therefore becomes a crucial issue for all applications. However, few studies are focused on the measurement of CEP with coherent...

Full description

Bibliographic Details
Main Authors: Feitao Li, Hui Hu, Wei Zhao, Yuanshan Liu
Format: Article
Language:English
Published: IEEE 2015-01-01
Series:IEEE Photonics Journal
Subjects:
Online Access:https://ieeexplore.ieee.org/document/7081341/
id doaj-153b49ed068341f5963734226e17efcc
record_format Article
spelling doaj-153b49ed068341f5963734226e17efcc2021-03-29T17:23:04ZengIEEEIEEE Photonics Journal1943-06552015-01-01731710.1109/JPHOT.2015.24206887081341Carrier-Envelope Phase Measurement With Linear Optical SamplingFeitao Li0Hui Hu1Wei Zhao2Yuanshan Liu3State Key Lab. of Transient Opt. & Photonics, Xi'an Inst. of Opt. & Precision Mech., Xi'an, ChinaState Key Lab. of Transient Opt. & Photonics, Xi'an Inst. of Opt. & Precision Mech., Xi'an, ChinaState Key Lab. of Transient Opt. & Photonics, Xi'an Inst. of Opt. & Precision Mech., Xi'an, ChinaState Key Lab. of Transient Opt. & Photonics, Xi'an Inst. of Opt. & Precision Mech., Xi'an, ChinaIn the few-cycle pulses, the temporal evolution of the electric field sensitively depends on the carrier-envelope phase (CEP). The ability to measure and stabilize the CEP therefore becomes a crucial issue for all applications. However, few studies are focused on the measurement of CEP with coherent linear optical sampling. We propose an efficient method to measure the CEP of the frequency comb pulses by employing a high-resolution linear optical sampling technique. It is shown that constant chirp and pulsewidth of frequency comb pulses have negligible effect on the CEP measurement.https://ieeexplore.ieee.org/document/7081341/Carrier-envelop phase measurementOptical samplingFourier optics and signal processing
collection DOAJ
language English
format Article
sources DOAJ
author Feitao Li
Hui Hu
Wei Zhao
Yuanshan Liu
spellingShingle Feitao Li
Hui Hu
Wei Zhao
Yuanshan Liu
Carrier-Envelope Phase Measurement With Linear Optical Sampling
IEEE Photonics Journal
Carrier-envelop phase measurement
Optical sampling
Fourier optics and signal processing
author_facet Feitao Li
Hui Hu
Wei Zhao
Yuanshan Liu
author_sort Feitao Li
title Carrier-Envelope Phase Measurement With Linear Optical Sampling
title_short Carrier-Envelope Phase Measurement With Linear Optical Sampling
title_full Carrier-Envelope Phase Measurement With Linear Optical Sampling
title_fullStr Carrier-Envelope Phase Measurement With Linear Optical Sampling
title_full_unstemmed Carrier-Envelope Phase Measurement With Linear Optical Sampling
title_sort carrier-envelope phase measurement with linear optical sampling
publisher IEEE
series IEEE Photonics Journal
issn 1943-0655
publishDate 2015-01-01
description In the few-cycle pulses, the temporal evolution of the electric field sensitively depends on the carrier-envelope phase (CEP). The ability to measure and stabilize the CEP therefore becomes a crucial issue for all applications. However, few studies are focused on the measurement of CEP with coherent linear optical sampling. We propose an efficient method to measure the CEP of the frequency comb pulses by employing a high-resolution linear optical sampling technique. It is shown that constant chirp and pulsewidth of frequency comb pulses have negligible effect on the CEP measurement.
topic Carrier-envelop phase measurement
Optical sampling
Fourier optics and signal processing
url https://ieeexplore.ieee.org/document/7081341/
work_keys_str_mv AT feitaoli carrierenvelopephasemeasurementwithlinearopticalsampling
AT huihu carrierenvelopephasemeasurementwithlinearopticalsampling
AT weizhao carrierenvelopephasemeasurementwithlinearopticalsampling
AT yuanshanliu carrierenvelopephasemeasurementwithlinearopticalsampling
_version_ 1724197812748419072