Determination of Explosion Protection Zones in Acetylene Facilities According to DGUV Rule 113-001

The presentation shows the transfer from old examples to the new (blue) edition of the sample collection within the DGUV rule 113-001 – Collection of technical rules for the avoidance of hazards from explosive atmospheres with sample collection to classify hazardous areas into zones (original name:...

Full description

Bibliographic Details
Main Author: Björn Poga
Format: Article
Language:English
Published: AIDIC Servizi S.r.l. 2016-04-01
Series:Chemical Engineering Transactions
Online Access:https://www.cetjournal.it/index.php/cet/article/view/3446
id doaj-151eff458656437583c08f9ea3486393
record_format Article
spelling doaj-151eff458656437583c08f9ea34863932021-02-19T21:12:07ZengAIDIC Servizi S.r.l.Chemical Engineering Transactions2283-92162016-04-014810.3303/CET1648161Determination of Explosion Protection Zones in Acetylene Facilities According to DGUV Rule 113-001Björn PogaThe presentation shows the transfer from old examples to the new (blue) edition of the sample collection within the DGUV rule 113-001 – Collection of technical rules for the avoidance of hazards from explosive atmospheres with sample collection to classify hazardous areas into zones (original name: “DGUV Regel 113- 001, Sammlung technischer Regeln für das Vermeiden der Gefahren durch explosionsfähige Atmosphäre mit Beispielsammlung zur Einteilung explosionsgefährdeter Bereiche in Zonen”, published by the German Social Accident Insurance) in accordance of the recommendations of the explosion protection experts from the German Social Accident Insurance, Industriegaseverband (Industrial Gases Association in Germany), authorities and notified bodies. To introduce into the topic, further contents are the identification and evaluation of examples for explosion hazards, places where explosion hazards are likely to occur (hazard area classification and zones) and measures to avoid explosion hazards or to protect against the consequences of an explosion. This procedure will be shown using examples for acetylene plants and customers supply systems within the publication DGUV rule 113-001. In the following the project is described. The project to transfer old examples to new example collection was initiated after consulting meeting with a member company of BG RCI. After identification and evaluation of examples for explosion hazards, places where explosion hazards are likely to occur (hazard area classification and zones), measures to avoid explosion hazards or to protect against the consequences of an explosion the created examples were assessed by explosion protection experts (authorities, notified bodies, industry, …). Finally the examples were published in DGUV rule 113-001. A selection of examples is shown in the presentation.https://www.cetjournal.it/index.php/cet/article/view/3446
collection DOAJ
language English
format Article
sources DOAJ
author Björn Poga
spellingShingle Björn Poga
Determination of Explosion Protection Zones in Acetylene Facilities According to DGUV Rule 113-001
Chemical Engineering Transactions
author_facet Björn Poga
author_sort Björn Poga
title Determination of Explosion Protection Zones in Acetylene Facilities According to DGUV Rule 113-001
title_short Determination of Explosion Protection Zones in Acetylene Facilities According to DGUV Rule 113-001
title_full Determination of Explosion Protection Zones in Acetylene Facilities According to DGUV Rule 113-001
title_fullStr Determination of Explosion Protection Zones in Acetylene Facilities According to DGUV Rule 113-001
title_full_unstemmed Determination of Explosion Protection Zones in Acetylene Facilities According to DGUV Rule 113-001
title_sort determination of explosion protection zones in acetylene facilities according to dguv rule 113-001
publisher AIDIC Servizi S.r.l.
series Chemical Engineering Transactions
issn 2283-9216
publishDate 2016-04-01
description The presentation shows the transfer from old examples to the new (blue) edition of the sample collection within the DGUV rule 113-001 – Collection of technical rules for the avoidance of hazards from explosive atmospheres with sample collection to classify hazardous areas into zones (original name: “DGUV Regel 113- 001, Sammlung technischer Regeln für das Vermeiden der Gefahren durch explosionsfähige Atmosphäre mit Beispielsammlung zur Einteilung explosionsgefährdeter Bereiche in Zonen”, published by the German Social Accident Insurance) in accordance of the recommendations of the explosion protection experts from the German Social Accident Insurance, Industriegaseverband (Industrial Gases Association in Germany), authorities and notified bodies. To introduce into the topic, further contents are the identification and evaluation of examples for explosion hazards, places where explosion hazards are likely to occur (hazard area classification and zones) and measures to avoid explosion hazards or to protect against the consequences of an explosion. This procedure will be shown using examples for acetylene plants and customers supply systems within the publication DGUV rule 113-001. In the following the project is described. The project to transfer old examples to new example collection was initiated after consulting meeting with a member company of BG RCI. After identification and evaluation of examples for explosion hazards, places where explosion hazards are likely to occur (hazard area classification and zones), measures to avoid explosion hazards or to protect against the consequences of an explosion the created examples were assessed by explosion protection experts (authorities, notified bodies, industry, …). Finally the examples were published in DGUV rule 113-001. A selection of examples is shown in the presentation.
url https://www.cetjournal.it/index.php/cet/article/view/3446
work_keys_str_mv AT bjornpoga determinationofexplosionprotectionzonesinacetylenefacilitiesaccordingtodguvrule113001
_version_ 1724260271833219072