Relationship between pre-anesthetic and intra-anesthetic airway resistance in patients undergoing general anesthesia: A prospective observational study.

Surgery patients in Japan undergo routine spirometry testing prior to general anesthesia. The use of a flow sensor during general anesthesia has recently become common. However, it is not certain whether the information derived from flow-volume curves is being adequately used for mechanical ventilat...

Full description

Bibliographic Details
Main Authors: Takamitsu Ikeda, Kanji Uchida, Yasuhiro Yamauchi, Takahide Nagase, Koji Oba, Yoshitsugu Yamada
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2017-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC5315306?pdf=render
id doaj-14eff261a3aa4d7ba4951004b0238031
record_format Article
spelling doaj-14eff261a3aa4d7ba4951004b02380312020-11-25T02:47:26ZengPublic Library of Science (PLoS)PLoS ONE1932-62032017-01-01122e017242110.1371/journal.pone.0172421Relationship between pre-anesthetic and intra-anesthetic airway resistance in patients undergoing general anesthesia: A prospective observational study.Takamitsu IkedaKanji UchidaYasuhiro YamauchiTakahide NagaseKoji ObaYoshitsugu YamadaSurgery patients in Japan undergo routine spirometry testing prior to general anesthesia. The use of a flow sensor during general anesthesia has recently become common. However, it is not certain whether the information derived from flow-volume curves is being adequately used for mechanical ventilation management during general anesthesia. So far, there have been no attempts to calculate airway resistance using flow-volume curves. Therefore, we performed a prospective, observational study to investigate the relationship between pre-anesthetic and intra-anesthetic airway resistance in patients scheduled for surgery under general anesthesia. We calculated pre-anesthetic and intra-anesthetic airway resistance in each patient, based on the slopes of flow-volume curves obtained prior to and during general anesthesia. We also calculated endotracheal tube resistance to correct the intra-anesthetic airway resistance values calculated. A total of 526 patients were included in the study, and 98 patients had a forced expiratory volume in the first second/forced vital capacity ratio of < 70%. Pre-anesthetic airway resistance was significantly higher in patients with airflow obstruction than in those without airflow obstruction (p < 0.001), whereas no significant difference in intra-anesthetic airway resistance was found between patients with and without airflow obstruction during mechanical ventilation (p = 0.48). Pre-anesthetic and intra-anesthetic airway resistance values were closer to each other in patients without airflow obstruction, with a mean difference < 1.0 cmH2O L-1s-1, than in those with airflow obstruction, although these respiratory parameters were significantly different (p < 0.001). Intra-anesthetic airway resistance was not related to the FEV1/FVC ratio, regardless of the degree to which the FEV1/FVC ratio reflected pre-anesthetic airway resistance. As compared with patients with airflow obstruction, the mean difference between pre-anesthetic and intra-anesthetic airway resistance was small in patients without airflow obstruction.http://europepmc.org/articles/PMC5315306?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Takamitsu Ikeda
Kanji Uchida
Yasuhiro Yamauchi
Takahide Nagase
Koji Oba
Yoshitsugu Yamada
spellingShingle Takamitsu Ikeda
Kanji Uchida
Yasuhiro Yamauchi
Takahide Nagase
Koji Oba
Yoshitsugu Yamada
Relationship between pre-anesthetic and intra-anesthetic airway resistance in patients undergoing general anesthesia: A prospective observational study.
PLoS ONE
author_facet Takamitsu Ikeda
Kanji Uchida
Yasuhiro Yamauchi
Takahide Nagase
Koji Oba
Yoshitsugu Yamada
author_sort Takamitsu Ikeda
title Relationship between pre-anesthetic and intra-anesthetic airway resistance in patients undergoing general anesthesia: A prospective observational study.
title_short Relationship between pre-anesthetic and intra-anesthetic airway resistance in patients undergoing general anesthesia: A prospective observational study.
title_full Relationship between pre-anesthetic and intra-anesthetic airway resistance in patients undergoing general anesthesia: A prospective observational study.
title_fullStr Relationship between pre-anesthetic and intra-anesthetic airway resistance in patients undergoing general anesthesia: A prospective observational study.
title_full_unstemmed Relationship between pre-anesthetic and intra-anesthetic airway resistance in patients undergoing general anesthesia: A prospective observational study.
title_sort relationship between pre-anesthetic and intra-anesthetic airway resistance in patients undergoing general anesthesia: a prospective observational study.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2017-01-01
description Surgery patients in Japan undergo routine spirometry testing prior to general anesthesia. The use of a flow sensor during general anesthesia has recently become common. However, it is not certain whether the information derived from flow-volume curves is being adequately used for mechanical ventilation management during general anesthesia. So far, there have been no attempts to calculate airway resistance using flow-volume curves. Therefore, we performed a prospective, observational study to investigate the relationship between pre-anesthetic and intra-anesthetic airway resistance in patients scheduled for surgery under general anesthesia. We calculated pre-anesthetic and intra-anesthetic airway resistance in each patient, based on the slopes of flow-volume curves obtained prior to and during general anesthesia. We also calculated endotracheal tube resistance to correct the intra-anesthetic airway resistance values calculated. A total of 526 patients were included in the study, and 98 patients had a forced expiratory volume in the first second/forced vital capacity ratio of < 70%. Pre-anesthetic airway resistance was significantly higher in patients with airflow obstruction than in those without airflow obstruction (p < 0.001), whereas no significant difference in intra-anesthetic airway resistance was found between patients with and without airflow obstruction during mechanical ventilation (p = 0.48). Pre-anesthetic and intra-anesthetic airway resistance values were closer to each other in patients without airflow obstruction, with a mean difference < 1.0 cmH2O L-1s-1, than in those with airflow obstruction, although these respiratory parameters were significantly different (p < 0.001). Intra-anesthetic airway resistance was not related to the FEV1/FVC ratio, regardless of the degree to which the FEV1/FVC ratio reflected pre-anesthetic airway resistance. As compared with patients with airflow obstruction, the mean difference between pre-anesthetic and intra-anesthetic airway resistance was small in patients without airflow obstruction.
url http://europepmc.org/articles/PMC5315306?pdf=render
work_keys_str_mv AT takamitsuikeda relationshipbetweenpreanestheticandintraanestheticairwayresistanceinpatientsundergoinggeneralanesthesiaaprospectiveobservationalstudy
AT kanjiuchida relationshipbetweenpreanestheticandintraanestheticairwayresistanceinpatientsundergoinggeneralanesthesiaaprospectiveobservationalstudy
AT yasuhiroyamauchi relationshipbetweenpreanestheticandintraanestheticairwayresistanceinpatientsundergoinggeneralanesthesiaaprospectiveobservationalstudy
AT takahidenagase relationshipbetweenpreanestheticandintraanestheticairwayresistanceinpatientsundergoinggeneralanesthesiaaprospectiveobservationalstudy
AT kojioba relationshipbetweenpreanestheticandintraanestheticairwayresistanceinpatientsundergoinggeneralanesthesiaaprospectiveobservationalstudy
AT yoshitsuguyamada relationshipbetweenpreanestheticandintraanestheticairwayresistanceinpatientsundergoinggeneralanesthesiaaprospectiveobservationalstudy
_version_ 1724753570032517120