Factors related to hypertensive phase after glaucoma drainage device implantation

Orathai Pitukcheewanont,1 Visanee Tantisevi,1 Sunee Chansangpetch,2 Prin Rojanapongpun1 1Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand; 2Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand Back...

Full description

Bibliographic Details
Main Authors: Pitukcheewanont O, Tantisevi V, Chansangpetch S, Rojanapongpun P
Format: Article
Language:English
Published: Dove Medical Press 2018-08-01
Series:Clinical Ophthalmology
Subjects:
Online Access:https://www.dovepress.com/factors-related-to-hypertensive-phase-after-glaucoma-drainage-device-i-peer-reviewed-article-OPTH
id doaj-14e8fa546a2f4bdea687031f9b837b96
record_format Article
spelling doaj-14e8fa546a2f4bdea687031f9b837b962020-11-24T21:19:09ZengDove Medical PressClinical Ophthalmology1177-54832018-08-01Volume 121479148639919Factors related to hypertensive phase after glaucoma drainage device implantationPitukcheewanont OTantisevi VChansangpetch SRojanapongpun POrathai Pitukcheewanont,1 Visanee Tantisevi,1 Sunee Chansangpetch,2 Prin Rojanapongpun1 1Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand; 2Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand Background: The aim of the study was to evaluate factors related to hypertensive phase (HP) after glaucoma drainage device (GDD) implantation.Patients and methods: Retrospective charts review of glaucoma patients who underwent GDD implantation and completed 12 months of follow-up at King Chulalongkorn Memorial Hospital since 2004 was performed. Patients were divided into two groups according to the presence or absence of HP. The data were analyzed for factors associated with HP. The surgical outcomes including surgical failure, post-operative visual acuity (VA), post-operative number of medications, post-operative intraocular pressure (IOP), and post-operative complication were compared between the two groups.Results: Seventy-two patients were included. Most were diagnosed with secondary glaucoma (N=51, 70.8%), and Baerveldt was the most implanted GDD (N=49, 68.1%). Mean ± SD of IOP was significantly lower: 27.1±9.6 mmHg at pre-operation and 13.7±59 mmHg at 12-month follow-up (p<0.001). HP was identified in 38/72 patients (52.8%, 95% CI 40.7–64.7). Risk factor of HP was pre-operative VA equal or better than 20/70 (p=0.021, OR 7.5; 95% CI 1.4–41.4). Presence of underlying heart disease (patients in this group had taken anti-platelets) was found as a protective factor for HP (p=0.027, OR 0.06; 95% CI 0.00–0.72). It was speculated that the anti-inflammatory effect of the anti-platelets, particularly aspirin, may be responsible for controlling inflammation and retarding fibrosis formation around drainage implants. Failure rate at 12 months was 24/72 (33%). There was no difference in all surgical outcomes between the two groups. Survival analysis also showed no significant difference between HP and non-HP group.Conclusion: HP commonly occurred after GDD implantation. Pre-operative VA was a risk factor for the development of HP, whereas presence of underlying heart disease was a protective factor. No association between HP and surgical outcomes was identified. Keywords: glaucoma implant, post-operative intraocular pressure, risk factors, surgical outcomeshttps://www.dovepress.com/factors-related-to-hypertensive-phase-after-glaucoma-drainage-device-i-peer-reviewed-article-OPTHGlaucoma implantpost-operative intra-ocular pressurerisk factorssurgical outcomes
collection DOAJ
language English
format Article
sources DOAJ
author Pitukcheewanont O
Tantisevi V
Chansangpetch S
Rojanapongpun P
spellingShingle Pitukcheewanont O
Tantisevi V
Chansangpetch S
Rojanapongpun P
Factors related to hypertensive phase after glaucoma drainage device implantation
Clinical Ophthalmology
Glaucoma implant
post-operative intra-ocular pressure
risk factors
surgical outcomes
author_facet Pitukcheewanont O
Tantisevi V
Chansangpetch S
Rojanapongpun P
author_sort Pitukcheewanont O
title Factors related to hypertensive phase after glaucoma drainage device implantation
title_short Factors related to hypertensive phase after glaucoma drainage device implantation
title_full Factors related to hypertensive phase after glaucoma drainage device implantation
title_fullStr Factors related to hypertensive phase after glaucoma drainage device implantation
title_full_unstemmed Factors related to hypertensive phase after glaucoma drainage device implantation
title_sort factors related to hypertensive phase after glaucoma drainage device implantation
publisher Dove Medical Press
series Clinical Ophthalmology
issn 1177-5483
publishDate 2018-08-01
description Orathai Pitukcheewanont,1 Visanee Tantisevi,1 Sunee Chansangpetch,2 Prin Rojanapongpun1 1Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand; 2Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand Background: The aim of the study was to evaluate factors related to hypertensive phase (HP) after glaucoma drainage device (GDD) implantation.Patients and methods: Retrospective charts review of glaucoma patients who underwent GDD implantation and completed 12 months of follow-up at King Chulalongkorn Memorial Hospital since 2004 was performed. Patients were divided into two groups according to the presence or absence of HP. The data were analyzed for factors associated with HP. The surgical outcomes including surgical failure, post-operative visual acuity (VA), post-operative number of medications, post-operative intraocular pressure (IOP), and post-operative complication were compared between the two groups.Results: Seventy-two patients were included. Most were diagnosed with secondary glaucoma (N=51, 70.8%), and Baerveldt was the most implanted GDD (N=49, 68.1%). Mean ± SD of IOP was significantly lower: 27.1±9.6 mmHg at pre-operation and 13.7±59 mmHg at 12-month follow-up (p<0.001). HP was identified in 38/72 patients (52.8%, 95% CI 40.7–64.7). Risk factor of HP was pre-operative VA equal or better than 20/70 (p=0.021, OR 7.5; 95% CI 1.4–41.4). Presence of underlying heart disease (patients in this group had taken anti-platelets) was found as a protective factor for HP (p=0.027, OR 0.06; 95% CI 0.00–0.72). It was speculated that the anti-inflammatory effect of the anti-platelets, particularly aspirin, may be responsible for controlling inflammation and retarding fibrosis formation around drainage implants. Failure rate at 12 months was 24/72 (33%). There was no difference in all surgical outcomes between the two groups. Survival analysis also showed no significant difference between HP and non-HP group.Conclusion: HP commonly occurred after GDD implantation. Pre-operative VA was a risk factor for the development of HP, whereas presence of underlying heart disease was a protective factor. No association between HP and surgical outcomes was identified. Keywords: glaucoma implant, post-operative intraocular pressure, risk factors, surgical outcomes
topic Glaucoma implant
post-operative intra-ocular pressure
risk factors
surgical outcomes
url https://www.dovepress.com/factors-related-to-hypertensive-phase-after-glaucoma-drainage-device-i-peer-reviewed-article-OPTH
work_keys_str_mv AT pitukcheewanonto factorsrelatedtohypertensivephaseafterglaucomadrainagedeviceimplantation
AT tantiseviv factorsrelatedtohypertensivephaseafterglaucomadrainagedeviceimplantation
AT chansangpetchs factorsrelatedtohypertensivephaseafterglaucomadrainagedeviceimplantation
AT rojanapongpunp factorsrelatedtohypertensivephaseafterglaucomadrainagedeviceimplantation
_version_ 1716736294133956608