Preliminary Study on the Quantitative Value Transfer Method of Absorbed Dose to Water in 60Co γ Radiation

Absorbed dose to water in 60Co γ radiation is the basic physics quantity in the quantitative value system of radiation therapy, it is very necessary for radiation therapy. The study on the quantitative value transfer method of absorbed dose to water in 60Co γ Radiation could provide important techni...

Full description

Bibliographic Details
Main Authors: SONG Ming-zhe, YE Hong-sheng, GAO Fei
Format: Article
Language:zho
Published: Editorial Board of Journal of Isotopes 2015-01-01
Series:Journal of Isotopes
Subjects:
Online Access:http://www.tws.org.cn/CN/10.7538/tws.2015.28.01.0028
id doaj-14512939c1084dafba430611a850f47d
record_format Article
spelling doaj-14512939c1084dafba430611a850f47d2020-11-25T02:40:44ZzhoEditorial Board of Journal of IsotopesJournal of Isotopes1000-75121000-75122015-01-012812832Preliminary Study on the Quantitative Value Transfer Method of Absorbed Dose to Water in 60Co γ RadiationSONG Ming-zhe0YE Hong-sheng1GAO Fei2WANG KunWEI Ke-xinHOU Jin-bingAbsorbed dose to water in 60Co γ radiation is the basic physics quantity in the quantitative value system of radiation therapy, it is very necessary for radiation therapy. The study on the quantitative value transfer method of absorbed dose to water in 60Co γ Radiation could provide important technical support to the establishment of Chinese absorbed dose to water quantity system. Based on PTW-30013 ionization chamber, PMMA water phantom and 3D mobile platform, quantitative value transfer standard instrument was established, combined with the requirement of IAEA-TRS398, developed preliminary study of 60Co absorbed dose to water quantity value transfer method. After the quantity value transfer, the expanded uncertainty of absorbed dose to water calibration factor of PTW-30013 was 0.90% (k=2), the expanded uncertainty of absorbed dose to water of 60Co γ reference radiation in Radiation Metrology Center (SSDL of IAEA) was 1.4% (k=2). The results showed that, this value transfer method can reduce the uncertainty of 60Co absorbed dose to water effectively in Secondary Standard Dosimetry Laboratory. http://www.tws.org.cn/CN/10.7538/tws.2015.28.01.0028 60Co absorbed dose to water quantitative value transfer
collection DOAJ
language zho
format Article
sources DOAJ
author SONG Ming-zhe
YE Hong-sheng
GAO Fei
spellingShingle SONG Ming-zhe
YE Hong-sheng
GAO Fei
Preliminary Study on the Quantitative Value Transfer Method of Absorbed Dose to Water in 60Co γ Radiation
Journal of Isotopes
60Co absorbed dose to water quantitative value transfer
author_facet SONG Ming-zhe
YE Hong-sheng
GAO Fei
author_sort SONG Ming-zhe
title Preliminary Study on the Quantitative Value Transfer Method of Absorbed Dose to Water in 60Co γ Radiation
title_short Preliminary Study on the Quantitative Value Transfer Method of Absorbed Dose to Water in 60Co γ Radiation
title_full Preliminary Study on the Quantitative Value Transfer Method of Absorbed Dose to Water in 60Co γ Radiation
title_fullStr Preliminary Study on the Quantitative Value Transfer Method of Absorbed Dose to Water in 60Co γ Radiation
title_full_unstemmed Preliminary Study on the Quantitative Value Transfer Method of Absorbed Dose to Water in 60Co γ Radiation
title_sort preliminary study on the quantitative value transfer method of absorbed dose to water in 60co γ radiation
publisher Editorial Board of Journal of Isotopes
series Journal of Isotopes
issn 1000-7512
1000-7512
publishDate 2015-01-01
description Absorbed dose to water in 60Co γ radiation is the basic physics quantity in the quantitative value system of radiation therapy, it is very necessary for radiation therapy. The study on the quantitative value transfer method of absorbed dose to water in 60Co γ Radiation could provide important technical support to the establishment of Chinese absorbed dose to water quantity system. Based on PTW-30013 ionization chamber, PMMA water phantom and 3D mobile platform, quantitative value transfer standard instrument was established, combined with the requirement of IAEA-TRS398, developed preliminary study of 60Co absorbed dose to water quantity value transfer method. After the quantity value transfer, the expanded uncertainty of absorbed dose to water calibration factor of PTW-30013 was 0.90% (k=2), the expanded uncertainty of absorbed dose to water of 60Co γ reference radiation in Radiation Metrology Center (SSDL of IAEA) was 1.4% (k=2). The results showed that, this value transfer method can reduce the uncertainty of 60Co absorbed dose to water effectively in Secondary Standard Dosimetry Laboratory.
topic 60Co absorbed dose to water quantitative value transfer
url http://www.tws.org.cn/CN/10.7538/tws.2015.28.01.0028
work_keys_str_mv AT songmingzhe preliminarystudyonthequantitativevaluetransfermethodofabsorbeddosetowaterin60cogradiation
AT yehongsheng preliminarystudyonthequantitativevaluetransfermethodofabsorbeddosetowaterin60cogradiation
AT gaofei preliminarystudyonthequantitativevaluetransfermethodofabsorbeddosetowaterin60cogradiation
_version_ 1724780055576444928