ANALYSIS OF SYSTEM CONNECTIONS OF THE TECHNOLOGICAL UNIT FUNCTIONING INDICATORS AND SOLVING THE PROBLEM OF CHOOSING OPTIONS FOR RESERVE CALCULATION BASED ON GEOPHYSICAL DATA

Background. The work carried out a comprehensive analysis system connection the main technical and technological parameters operation technological units of the underground well leaching mine uranium. Materials and methods. The analysis was based on the development an information model technolog...

Full description

Bibliographic Details
Main Author: D. R. Podrezov
Format: Article
Language:English
Published: Penza State University Publishing House 2020-06-01
Series:Известия высших учебных заведений. Поволжский регион:Технические науки
Subjects:
id doaj-13d62c4363b1467ca3c7b64a36bbac42
record_format Article
spelling doaj-13d62c4363b1467ca3c7b64a36bbac422020-11-25T01:59:44ZengPenza State University Publishing HouseИзвестия высших учебных заведений. Поволжский регион:Технические науки2072-30592020-06-01210.21685/2072-3059-2020-2-4ANALYSIS OF SYSTEM CONNECTIONS OF THE TECHNOLOGICAL UNIT FUNCTIONING INDICATORS AND SOLVING THE PROBLEM OF CHOOSING OPTIONS FOR RESERVE CALCULATION BASED ON GEOPHYSICAL DATAD. R. Podrezov0MISIS National University of Science and TechnologyBackground. The work carried out a comprehensive analysis system connection the main technical and technological parameters operation technological units of the underground well leaching mine uranium. Materials and methods. The analysis was based on the development an information model technological wells operation, which allowed to determine the relationships between the main volume and quality development indicators of reserves at the field, such as: mining mass volumes; the opened stocks volumes; metal extraction; average uranium concentration; an ore interval size. Results. The geological and technological information analysis carried out within the framework information model developed, as well as evolution assessment reserves during the development the field blocks showed that 76% the functioning technological blocks at the field show re-attraction by actual indicators or expected in the near future by forecast estimates. In order to adequately estimate the technological unit’s reserves, the initial set factor features determining the opened reserves volumes and the production volumes at the field was formed: effective capacity interval acidified productive horizon; unit process wells grouping; the technological block area. Conclusions. The inventory conversion results showed that the actual uranium reserves in the subsoil did not correspond to the actual development. In addition, it was found that the exposed reserves systematic underestimation was also related to the uranium content calculation in ore intervals, which is, to the radioactive equilibrium coefficient taken into account value.factor groupingssystem communicationsfunctioning efficiencythe choice problemstocks calculation
collection DOAJ
language English
format Article
sources DOAJ
author D. R. Podrezov
spellingShingle D. R. Podrezov
ANALYSIS OF SYSTEM CONNECTIONS OF THE TECHNOLOGICAL UNIT FUNCTIONING INDICATORS AND SOLVING THE PROBLEM OF CHOOSING OPTIONS FOR RESERVE CALCULATION BASED ON GEOPHYSICAL DATA
Известия высших учебных заведений. Поволжский регион:Технические науки
factor groupings
system communications
functioning efficiency
the choice problem
stocks calculation
author_facet D. R. Podrezov
author_sort D. R. Podrezov
title ANALYSIS OF SYSTEM CONNECTIONS OF THE TECHNOLOGICAL UNIT FUNCTIONING INDICATORS AND SOLVING THE PROBLEM OF CHOOSING OPTIONS FOR RESERVE CALCULATION BASED ON GEOPHYSICAL DATA
title_short ANALYSIS OF SYSTEM CONNECTIONS OF THE TECHNOLOGICAL UNIT FUNCTIONING INDICATORS AND SOLVING THE PROBLEM OF CHOOSING OPTIONS FOR RESERVE CALCULATION BASED ON GEOPHYSICAL DATA
title_full ANALYSIS OF SYSTEM CONNECTIONS OF THE TECHNOLOGICAL UNIT FUNCTIONING INDICATORS AND SOLVING THE PROBLEM OF CHOOSING OPTIONS FOR RESERVE CALCULATION BASED ON GEOPHYSICAL DATA
title_fullStr ANALYSIS OF SYSTEM CONNECTIONS OF THE TECHNOLOGICAL UNIT FUNCTIONING INDICATORS AND SOLVING THE PROBLEM OF CHOOSING OPTIONS FOR RESERVE CALCULATION BASED ON GEOPHYSICAL DATA
title_full_unstemmed ANALYSIS OF SYSTEM CONNECTIONS OF THE TECHNOLOGICAL UNIT FUNCTIONING INDICATORS AND SOLVING THE PROBLEM OF CHOOSING OPTIONS FOR RESERVE CALCULATION BASED ON GEOPHYSICAL DATA
title_sort analysis of system connections of the technological unit functioning indicators and solving the problem of choosing options for reserve calculation based on geophysical data
publisher Penza State University Publishing House
series Известия высших учебных заведений. Поволжский регион:Технические науки
issn 2072-3059
publishDate 2020-06-01
description Background. The work carried out a comprehensive analysis system connection the main technical and technological parameters operation technological units of the underground well leaching mine uranium. Materials and methods. The analysis was based on the development an information model technological wells operation, which allowed to determine the relationships between the main volume and quality development indicators of reserves at the field, such as: mining mass volumes; the opened stocks volumes; metal extraction; average uranium concentration; an ore interval size. Results. The geological and technological information analysis carried out within the framework information model developed, as well as evolution assessment reserves during the development the field blocks showed that 76% the functioning technological blocks at the field show re-attraction by actual indicators or expected in the near future by forecast estimates. In order to adequately estimate the technological unit’s reserves, the initial set factor features determining the opened reserves volumes and the production volumes at the field was formed: effective capacity interval acidified productive horizon; unit process wells grouping; the technological block area. Conclusions. The inventory conversion results showed that the actual uranium reserves in the subsoil did not correspond to the actual development. In addition, it was found that the exposed reserves systematic underestimation was also related to the uranium content calculation in ore intervals, which is, to the radioactive equilibrium coefficient taken into account value.
topic factor groupings
system communications
functioning efficiency
the choice problem
stocks calculation
work_keys_str_mv AT drpodrezov analysisofsystemconnectionsofthetechnologicalunitfunctioningindicatorsandsolvingtheproblemofchoosingoptionsforreservecalculationbasedongeophysicaldata
_version_ 1724962911909052416