Several years of experience with automatic DI-flux systems: theory, validation and results

The previous release of our automatic DI-flux instrument, called AutoDIF mk2.2, has now been running continuously since June 2012 in the absolute house of Dourbes magnetic observatory performing measurement every 30 min. A second one has been working in the tunnel of Conrad observatory (Austria)...

Full description

Bibliographic Details
Main Authors: A. Poncelet, A. Gonsette, J. Rasson
Format: Article
Language:English
Published: Copernicus Publications 2017-09-01
Series:Geoscientific Instrumentation, Methods and Data Systems
Online Access:https://www.geosci-instrum-method-data-syst.net/6/353/2017/gi-6-353-2017.pdf
id doaj-13d341f94b0944bf8948cbad42bdd4c9
record_format Article
spelling doaj-13d341f94b0944bf8948cbad42bdd4c92020-11-24T22:21:26ZengCopernicus PublicationsGeoscientific Instrumentation, Methods and Data Systems2193-08562193-08642017-09-01635336010.5194/gi-6-353-2017Several years of experience with automatic DI-flux systems: theory, validation and resultsA. Poncelet0A. Gonsette1J. Rasson2Royal Meteorological Institute of Belgium, Rue du Centre de Physique 4, 5670 Dourbes, BelgiumRoyal Meteorological Institute of Belgium, Rue du Centre de Physique 4, 5670 Dourbes, BelgiumRoyal Meteorological Institute of Belgium, Rue du Centre de Physique 4, 5670 Dourbes, BelgiumThe previous release of our automatic DI-flux instrument, called AutoDIF mk2.2, has now been running continuously since June 2012 in the absolute house of Dourbes magnetic observatory performing measurement every 30 min. A second one has been working in the tunnel of Conrad observatory (Austria) since December 2013. After this proof of concept, we improved the AutoDIF to version mk2.3, which was presented at the 16th IAGA workshop in Hyderabad. As of publication, we have successfully deployed six AutoDIFs in various environments: two in Dourbes (DOU), one in Manhay (MAB), one in Conrad (CON), one in Daejeon (South Korea) and one is used for tests. The latter was installed for 10 months in Chambon-la-Forêt (CLF) and, since 2016, has been in Kakioka (KAK). In this paper, we will compare the automatic to the human-made measurements and discuss the advantages and disadvantages of automatic measurements.https://www.geosci-instrum-method-data-syst.net/6/353/2017/gi-6-353-2017.pdf
collection DOAJ
language English
format Article
sources DOAJ
author A. Poncelet
A. Gonsette
J. Rasson
spellingShingle A. Poncelet
A. Gonsette
J. Rasson
Several years of experience with automatic DI-flux systems: theory, validation and results
Geoscientific Instrumentation, Methods and Data Systems
author_facet A. Poncelet
A. Gonsette
J. Rasson
author_sort A. Poncelet
title Several years of experience with automatic DI-flux systems: theory, validation and results
title_short Several years of experience with automatic DI-flux systems: theory, validation and results
title_full Several years of experience with automatic DI-flux systems: theory, validation and results
title_fullStr Several years of experience with automatic DI-flux systems: theory, validation and results
title_full_unstemmed Several years of experience with automatic DI-flux systems: theory, validation and results
title_sort several years of experience with automatic di-flux systems: theory, validation and results
publisher Copernicus Publications
series Geoscientific Instrumentation, Methods and Data Systems
issn 2193-0856
2193-0864
publishDate 2017-09-01
description The previous release of our automatic DI-flux instrument, called AutoDIF mk2.2, has now been running continuously since June 2012 in the absolute house of Dourbes magnetic observatory performing measurement every 30 min. A second one has been working in the tunnel of Conrad observatory (Austria) since December 2013. After this proof of concept, we improved the AutoDIF to version mk2.3, which was presented at the 16th IAGA workshop in Hyderabad. As of publication, we have successfully deployed six AutoDIFs in various environments: two in Dourbes (DOU), one in Manhay (MAB), one in Conrad (CON), one in Daejeon (South Korea) and one is used for tests. The latter was installed for 10 months in Chambon-la-Forêt (CLF) and, since 2016, has been in Kakioka (KAK). In this paper, we will compare the automatic to the human-made measurements and discuss the advantages and disadvantages of automatic measurements.
url https://www.geosci-instrum-method-data-syst.net/6/353/2017/gi-6-353-2017.pdf
work_keys_str_mv AT aponcelet severalyearsofexperiencewithautomaticdifluxsystemstheoryvalidationandresults
AT agonsette severalyearsofexperiencewithautomaticdifluxsystemstheoryvalidationandresults
AT jrasson severalyearsofexperiencewithautomaticdifluxsystemstheoryvalidationandresults
_version_ 1725771179362353152