Robust Adaptive Reactive Power Control for Doubly Fed Induction Generator
The problem of reactive power control for mains-side inverter (MSI) in doubly fed induction generator (DFIG) is studied in this paper. To accommodate the modelling nonlinearities and inherent uncertainties, a novel robust adaptive control algorithm for MSI is proposed by utilizing Lyapunov theory th...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2014-01-01
|
Series: | Abstract and Applied Analysis |
Online Access: | http://dx.doi.org/10.1155/2014/369349 |
id |
doaj-13519a41dfcb40eda026b2befbc9eee0 |
---|---|
record_format |
Article |
spelling |
doaj-13519a41dfcb40eda026b2befbc9eee02020-11-24T22:35:23ZengHindawi LimitedAbstract and Applied Analysis1085-33751687-04092014-01-01201410.1155/2014/369349369349Robust Adaptive Reactive Power Control for Doubly Fed Induction GeneratorHuabin Wen0Yu Zeng1Lei Wang2Feng Yang3Y. D. Song4School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, ChinaSchool of Energy Science and Engineering, UESTC, Chengdu 611731, ChinaSchool of Automation, Chongqing University, Chongqing 400044, ChinaSchool of Automation Engineering, UESTC, Chengdu 611731, ChinaSchool of Automation, Chongqing University, Chongqing 400044, ChinaThe problem of reactive power control for mains-side inverter (MSI) in doubly fed induction generator (DFIG) is studied in this paper. To accommodate the modelling nonlinearities and inherent uncertainties, a novel robust adaptive control algorithm for MSI is proposed by utilizing Lyapunov theory that ensures asymptotic stability of the system under unpredictable external disturbances and significant parametric uncertainties. The distinguishing benefit of the aforementioned scheme consists in its capabilities to maintain satisfactory performance under varying operation conditions without the need for manually redesigning or reprogramming the control gains in contrast to the commonly used PI/PID control. Simulations are also built to confirm the correctness and benefits of the control scheme.http://dx.doi.org/10.1155/2014/369349 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Huabin Wen Yu Zeng Lei Wang Feng Yang Y. D. Song |
spellingShingle |
Huabin Wen Yu Zeng Lei Wang Feng Yang Y. D. Song Robust Adaptive Reactive Power Control for Doubly Fed Induction Generator Abstract and Applied Analysis |
author_facet |
Huabin Wen Yu Zeng Lei Wang Feng Yang Y. D. Song |
author_sort |
Huabin Wen |
title |
Robust Adaptive Reactive Power Control for Doubly Fed Induction Generator |
title_short |
Robust Adaptive Reactive Power Control for Doubly Fed Induction Generator |
title_full |
Robust Adaptive Reactive Power Control for Doubly Fed Induction Generator |
title_fullStr |
Robust Adaptive Reactive Power Control for Doubly Fed Induction Generator |
title_full_unstemmed |
Robust Adaptive Reactive Power Control for Doubly Fed Induction Generator |
title_sort |
robust adaptive reactive power control for doubly fed induction generator |
publisher |
Hindawi Limited |
series |
Abstract and Applied Analysis |
issn |
1085-3375 1687-0409 |
publishDate |
2014-01-01 |
description |
The problem of reactive power control for mains-side inverter (MSI) in doubly fed induction generator (DFIG) is studied in this paper. To accommodate the modelling nonlinearities and inherent uncertainties, a novel robust adaptive control algorithm for MSI is proposed by utilizing Lyapunov theory that ensures asymptotic stability of the system under unpredictable external disturbances and significant parametric uncertainties. The distinguishing benefit of the aforementioned scheme consists in its capabilities to maintain satisfactory performance under varying operation conditions without the need for manually redesigning or reprogramming the control gains in contrast to the commonly used PI/PID control. Simulations are also built to confirm the correctness and benefits of the control scheme. |
url |
http://dx.doi.org/10.1155/2014/369349 |
work_keys_str_mv |
AT huabinwen robustadaptivereactivepowercontrolfordoublyfedinductiongenerator AT yuzeng robustadaptivereactivepowercontrolfordoublyfedinductiongenerator AT leiwang robustadaptivereactivepowercontrolfordoublyfedinductiongenerator AT fengyang robustadaptivereactivepowercontrolfordoublyfedinductiongenerator AT ydsong robustadaptivereactivepowercontrolfordoublyfedinductiongenerator |