Removal of NO from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column system

Emissions of NO X from automobile causes various environmental impacts. In order to satisfy the emission norms and standards, it is necessary to reduce the toxic gases from emission. This paper concentrates on designing a packed column and analysis on the selection of an effective absorbent to reduc...

Full description

Bibliographic Details
Main Authors: V Arunkumar, K Krishnamurthy, C Maheswari, B Meenakshipriya, R Vinoth
Format: Article
Language:English
Published: SAGE Publishing 2019-09-01
Series:Measurement + Control
Online Access:https://doi.org/10.1177/0020294019858167
id doaj-12e3d4ad42e34eb8b20f93a3bec22c8d
record_format Article
spelling doaj-12e3d4ad42e34eb8b20f93a3bec22c8d2020-11-25T03:11:30ZengSAGE PublishingMeasurement + Control0020-29402019-09-015210.1177/0020294019858167Removal of NO from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column systemV Arunkumar0K Krishnamurthy1C Maheswari2B Meenakshipriya3R Vinoth4Mechatronics Engineering, Kongu Engineering College, Perundurai, IndiaMechatronics Engineering, Kongu Engineering College, Perundurai, IndiaMechatronics Engineering, Kongu Engineering College, Perundurai, IndiaMechatronics Engineering, Kongu Engineering College, Perundurai, IndiaMechatronics Engineering, Kamaraj College of Engineering and Technology, Virudhunagar, IndiaEmissions of NO X from automobile causes various environmental impacts. In order to satisfy the emission norms and standards, it is necessary to reduce the toxic gases from emission. This paper concentrates on designing a packed column and analysis on the selection of an effective absorbent to reduce NO X emission from diesel engines. NO X emission is taken from the exhaust of diesel engine (Kirloskar TV1 Diesel engine). Flue gas inlet to the packed column and the treated gas at the outlet of the packed column are measured using NO X inlet and outlet gas sensors, respectively. Absorbent flow is carried out in a lab-scale packed column experimental setup. Various parameters of the packed column such as liquid: gas ratio, diameter, total height and packing height are determined based on the mathematical modeling. The NO X emission was experimentally measured with various combinations of different absorbents with different flow rate. Based on the experiments, effective absorbents are chosen as NaClO 2 and NaOH. Experimental results show chemical absorbent combination with 0.5 M concentration of sodium chlorite and 0.3 M concentration of sodium hydroxide at 80% data acquisition card opening condition is absorbing NO X effectively.https://doi.org/10.1177/0020294019858167
collection DOAJ
language English
format Article
sources DOAJ
author V Arunkumar
K Krishnamurthy
C Maheswari
B Meenakshipriya
R Vinoth
spellingShingle V Arunkumar
K Krishnamurthy
C Maheswari
B Meenakshipriya
R Vinoth
Removal of NO from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column system
Measurement + Control
author_facet V Arunkumar
K Krishnamurthy
C Maheswari
B Meenakshipriya
R Vinoth
author_sort V Arunkumar
title Removal of NO from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column system
title_short Removal of NO from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column system
title_full Removal of NO from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column system
title_fullStr Removal of NO from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column system
title_full_unstemmed Removal of NO from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column system
title_sort removal of no from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column system
publisher SAGE Publishing
series Measurement + Control
issn 0020-2940
publishDate 2019-09-01
description Emissions of NO X from automobile causes various environmental impacts. In order to satisfy the emission norms and standards, it is necessary to reduce the toxic gases from emission. This paper concentrates on designing a packed column and analysis on the selection of an effective absorbent to reduce NO X emission from diesel engines. NO X emission is taken from the exhaust of diesel engine (Kirloskar TV1 Diesel engine). Flue gas inlet to the packed column and the treated gas at the outlet of the packed column are measured using NO X inlet and outlet gas sensors, respectively. Absorbent flow is carried out in a lab-scale packed column experimental setup. Various parameters of the packed column such as liquid: gas ratio, diameter, total height and packing height are determined based on the mathematical modeling. The NO X emission was experimentally measured with various combinations of different absorbents with different flow rate. Based on the experiments, effective absorbents are chosen as NaClO 2 and NaOH. Experimental results show chemical absorbent combination with 0.5 M concentration of sodium chlorite and 0.3 M concentration of sodium hydroxide at 80% data acquisition card opening condition is absorbing NO X effectively.
url https://doi.org/10.1177/0020294019858167
work_keys_str_mv AT varunkumar removalofnofromdieselengineexhaustbyusingdifferentchemicalabsorbentinalabscalepackedcolumnsystem
AT kkrishnamurthy removalofnofromdieselengineexhaustbyusingdifferentchemicalabsorbentinalabscalepackedcolumnsystem
AT cmaheswari removalofnofromdieselengineexhaustbyusingdifferentchemicalabsorbentinalabscalepackedcolumnsystem
AT bmeenakshipriya removalofnofromdieselengineexhaustbyusingdifferentchemicalabsorbentinalabscalepackedcolumnsystem
AT rvinoth removalofnofromdieselengineexhaustbyusingdifferentchemicalabsorbentinalabscalepackedcolumnsystem
_version_ 1724653828574281728