Removal of NO from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column system
Emissions of NO X from automobile causes various environmental impacts. In order to satisfy the emission norms and standards, it is necessary to reduce the toxic gases from emission. This paper concentrates on designing a packed column and analysis on the selection of an effective absorbent to reduc...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
SAGE Publishing
2019-09-01
|
Series: | Measurement + Control |
Online Access: | https://doi.org/10.1177/0020294019858167 |
id |
doaj-12e3d4ad42e34eb8b20f93a3bec22c8d |
---|---|
record_format |
Article |
spelling |
doaj-12e3d4ad42e34eb8b20f93a3bec22c8d2020-11-25T03:11:30ZengSAGE PublishingMeasurement + Control0020-29402019-09-015210.1177/0020294019858167Removal of NO from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column systemV Arunkumar0K Krishnamurthy1C Maheswari2B Meenakshipriya3R Vinoth4Mechatronics Engineering, Kongu Engineering College, Perundurai, IndiaMechatronics Engineering, Kongu Engineering College, Perundurai, IndiaMechatronics Engineering, Kongu Engineering College, Perundurai, IndiaMechatronics Engineering, Kongu Engineering College, Perundurai, IndiaMechatronics Engineering, Kamaraj College of Engineering and Technology, Virudhunagar, IndiaEmissions of NO X from automobile causes various environmental impacts. In order to satisfy the emission norms and standards, it is necessary to reduce the toxic gases from emission. This paper concentrates on designing a packed column and analysis on the selection of an effective absorbent to reduce NO X emission from diesel engines. NO X emission is taken from the exhaust of diesel engine (Kirloskar TV1 Diesel engine). Flue gas inlet to the packed column and the treated gas at the outlet of the packed column are measured using NO X inlet and outlet gas sensors, respectively. Absorbent flow is carried out in a lab-scale packed column experimental setup. Various parameters of the packed column such as liquid: gas ratio, diameter, total height and packing height are determined based on the mathematical modeling. The NO X emission was experimentally measured with various combinations of different absorbents with different flow rate. Based on the experiments, effective absorbents are chosen as NaClO 2 and NaOH. Experimental results show chemical absorbent combination with 0.5 M concentration of sodium chlorite and 0.3 M concentration of sodium hydroxide at 80% data acquisition card opening condition is absorbing NO X effectively.https://doi.org/10.1177/0020294019858167 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
V Arunkumar K Krishnamurthy C Maheswari B Meenakshipriya R Vinoth |
spellingShingle |
V Arunkumar K Krishnamurthy C Maheswari B Meenakshipriya R Vinoth Removal of NO from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column system Measurement + Control |
author_facet |
V Arunkumar K Krishnamurthy C Maheswari B Meenakshipriya R Vinoth |
author_sort |
V Arunkumar |
title |
Removal of NO from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column system |
title_short |
Removal of NO from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column system |
title_full |
Removal of NO from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column system |
title_fullStr |
Removal of NO from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column system |
title_full_unstemmed |
Removal of NO from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column system |
title_sort |
removal of no from diesel engine exhaust by using different chemical absorbent in a lab-scale packed column system |
publisher |
SAGE Publishing |
series |
Measurement + Control |
issn |
0020-2940 |
publishDate |
2019-09-01 |
description |
Emissions of NO X from automobile causes various environmental impacts. In order to satisfy the emission norms and standards, it is necessary to reduce the toxic gases from emission. This paper concentrates on designing a packed column and analysis on the selection of an effective absorbent to reduce NO X emission from diesel engines. NO X emission is taken from the exhaust of diesel engine (Kirloskar TV1 Diesel engine). Flue gas inlet to the packed column and the treated gas at the outlet of the packed column are measured using NO X inlet and outlet gas sensors, respectively. Absorbent flow is carried out in a lab-scale packed column experimental setup. Various parameters of the packed column such as liquid: gas ratio, diameter, total height and packing height are determined based on the mathematical modeling. The NO X emission was experimentally measured with various combinations of different absorbents with different flow rate. Based on the experiments, effective absorbents are chosen as NaClO 2 and NaOH. Experimental results show chemical absorbent combination with 0.5 M concentration of sodium chlorite and 0.3 M concentration of sodium hydroxide at 80% data acquisition card opening condition is absorbing NO X effectively. |
url |
https://doi.org/10.1177/0020294019858167 |
work_keys_str_mv |
AT varunkumar removalofnofromdieselengineexhaustbyusingdifferentchemicalabsorbentinalabscalepackedcolumnsystem AT kkrishnamurthy removalofnofromdieselengineexhaustbyusingdifferentchemicalabsorbentinalabscalepackedcolumnsystem AT cmaheswari removalofnofromdieselengineexhaustbyusingdifferentchemicalabsorbentinalabscalepackedcolumnsystem AT bmeenakshipriya removalofnofromdieselengineexhaustbyusingdifferentchemicalabsorbentinalabscalepackedcolumnsystem AT rvinoth removalofnofromdieselengineexhaustbyusingdifferentchemicalabsorbentinalabscalepackedcolumnsystem |
_version_ |
1724653828574281728 |