Choice of sterilizing/disinfecting agent: determination of the Decimal ReductionTime (D-Value)

Efforts to diminish the transmission of infections include programs in which disinfectants play a crucial role. Hospital surfaces and medical devices are potential sources of cross contamination, and each instrument, surface or area in a health care unit can be responsible for spread of infection. T...

Full description

Bibliographic Details
Main Authors: Priscila Gava Mazzola, Angela Faustino Jozala, Letícia Célia de Lencastre Novaes, Patricia Moriel, Thereza Christina Vessoni Penna
Format: Article
Language:English
Published: Universidade de São Paulo 2009-12-01
Series:Brazilian Journal of Pharmaceutical Sciences
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502009000400013
id doaj-1260a355fc4e4e94957bdbb4b35a6546
record_format Article
spelling doaj-1260a355fc4e4e94957bdbb4b35a65462020-11-25T02:25:52ZengUniversidade de São PauloBrazilian Journal of Pharmaceutical Sciences1984-82502175-97902009-12-0145470170810.1590/S1984-82502009000400013Choice of sterilizing/disinfecting agent: determination of the Decimal ReductionTime (D-Value)Priscila Gava MazzolaAngela Faustino JozalaLetícia Célia de Lencastre NovaesPatricia MorielThereza Christina Vessoni PennaEfforts to diminish the transmission of infections include programs in which disinfectants play a crucial role. Hospital surfaces and medical devices are potential sources of cross contamination, and each instrument, surface or area in a health care unit can be responsible for spread of infection. The decimal reduction time was used to study and compare the behavior of selected strains of microorganisms. The highest D-values for various bacteria were obtained for the following solutions: (i) 0.1% sodium dichloroisocyanurate (pH 7.0) - E. coli and A. calcoaceticus (D = 5.9 min); (ii) sodium hypochlorite (pH 7.0) at 0.025% for B. stearothermophilus (D = 24 min), E. coli and E. cloacae (D = 7.5 min); at 0.05% for B. stearothermophilus (D = 9.4 min) and E. coli (D = 6.1 min). The suspension studies were an indication of the disinfectant efficacy on a surface. The data in this study reflect the formulations used and may vary from product to product. The expected effectiveness from the studied formulations shows that the tested agents can be recommended for surface disinfection as stated in present guidelines and emphasize the importance and need to develop routine and novel programs to evaluate product utility.<br>Esforços para diminuir o risco de transmissões de infecções incluem programas nos quais os desinfetantes desempenham papel crucial. As superfícies de materiais médico-hospitalares, se não estiverem diretamente ligados à transmissão de doenças, podem contribuir, potencialmente, para uma contaminação cruzada secundária. Cada instrumento ou superfície do estabelecimento do ambiente de saúde que entra em contato com um paciente é um disseminador potencial de infecção. Para estudar e comparar o comportamento dos microrganismos selecionados foram realizados ensaios de determinação do tempo de redução decimal. Os maiores valores D determinados, foram: (i) 0,1% dicloroisocianurato de sódio (NaDCC) (pH 7.0) - E. coli e A. calcoaceticus (D = 5,9 min); (ii) hipoclorito de sódio (pH 7,0) à 0,025% para B. stearothermophilus (D = 24 min), E. coli e E. cloacae (D = 7,5 min); e à 0,05% para B. stearothermophilus (D = 9,4 min) e E. coli (D = 6,1 min). Este estudo estabelece que as suspensões estudadas são indicação da eficácia de desinfecção recomendada pela legislação, mas os resultados podem variar de produto para produto. Para desinfecção de mãos clorexidina pode ser utilizada, pois apresentou valores D baixos. Para desinfecção de nível intermediário de equipamentos e instrumentos recomenda-se a utilização de NaDCC, devido à estabilidade e baixo efeito corrosivo para equipamentos e materiais. Glutaraldeído, apesar de muito aceito para processos esterilizantes, tem eficácia comparável a soluções de formaldeído.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502009000400013DeseinfecçãoAgentes desinfetantesTempo de redução decimalDisinfectionDisinfectant agentsDecimal reduction time
collection DOAJ
language English
format Article
sources DOAJ
author Priscila Gava Mazzola
Angela Faustino Jozala
Letícia Célia de Lencastre Novaes
Patricia Moriel
Thereza Christina Vessoni Penna
spellingShingle Priscila Gava Mazzola
Angela Faustino Jozala
Letícia Célia de Lencastre Novaes
Patricia Moriel
Thereza Christina Vessoni Penna
Choice of sterilizing/disinfecting agent: determination of the Decimal ReductionTime (D-Value)
Brazilian Journal of Pharmaceutical Sciences
Deseinfecção
Agentes desinfetantes
Tempo de redução decimal
Disinfection
Disinfectant agents
Decimal reduction time
author_facet Priscila Gava Mazzola
Angela Faustino Jozala
Letícia Célia de Lencastre Novaes
Patricia Moriel
Thereza Christina Vessoni Penna
author_sort Priscila Gava Mazzola
title Choice of sterilizing/disinfecting agent: determination of the Decimal ReductionTime (D-Value)
title_short Choice of sterilizing/disinfecting agent: determination of the Decimal ReductionTime (D-Value)
title_full Choice of sterilizing/disinfecting agent: determination of the Decimal ReductionTime (D-Value)
title_fullStr Choice of sterilizing/disinfecting agent: determination of the Decimal ReductionTime (D-Value)
title_full_unstemmed Choice of sterilizing/disinfecting agent: determination of the Decimal ReductionTime (D-Value)
title_sort choice of sterilizing/disinfecting agent: determination of the decimal reductiontime (d-value)
publisher Universidade de São Paulo
series Brazilian Journal of Pharmaceutical Sciences
issn 1984-8250
2175-9790
publishDate 2009-12-01
description Efforts to diminish the transmission of infections include programs in which disinfectants play a crucial role. Hospital surfaces and medical devices are potential sources of cross contamination, and each instrument, surface or area in a health care unit can be responsible for spread of infection. The decimal reduction time was used to study and compare the behavior of selected strains of microorganisms. The highest D-values for various bacteria were obtained for the following solutions: (i) 0.1% sodium dichloroisocyanurate (pH 7.0) - E. coli and A. calcoaceticus (D = 5.9 min); (ii) sodium hypochlorite (pH 7.0) at 0.025% for B. stearothermophilus (D = 24 min), E. coli and E. cloacae (D = 7.5 min); at 0.05% for B. stearothermophilus (D = 9.4 min) and E. coli (D = 6.1 min). The suspension studies were an indication of the disinfectant efficacy on a surface. The data in this study reflect the formulations used and may vary from product to product. The expected effectiveness from the studied formulations shows that the tested agents can be recommended for surface disinfection as stated in present guidelines and emphasize the importance and need to develop routine and novel programs to evaluate product utility.<br>Esforços para diminuir o risco de transmissões de infecções incluem programas nos quais os desinfetantes desempenham papel crucial. As superfícies de materiais médico-hospitalares, se não estiverem diretamente ligados à transmissão de doenças, podem contribuir, potencialmente, para uma contaminação cruzada secundária. Cada instrumento ou superfície do estabelecimento do ambiente de saúde que entra em contato com um paciente é um disseminador potencial de infecção. Para estudar e comparar o comportamento dos microrganismos selecionados foram realizados ensaios de determinação do tempo de redução decimal. Os maiores valores D determinados, foram: (i) 0,1% dicloroisocianurato de sódio (NaDCC) (pH 7.0) - E. coli e A. calcoaceticus (D = 5,9 min); (ii) hipoclorito de sódio (pH 7,0) à 0,025% para B. stearothermophilus (D = 24 min), E. coli e E. cloacae (D = 7,5 min); e à 0,05% para B. stearothermophilus (D = 9,4 min) e E. coli (D = 6,1 min). Este estudo estabelece que as suspensões estudadas são indicação da eficácia de desinfecção recomendada pela legislação, mas os resultados podem variar de produto para produto. Para desinfecção de mãos clorexidina pode ser utilizada, pois apresentou valores D baixos. Para desinfecção de nível intermediário de equipamentos e instrumentos recomenda-se a utilização de NaDCC, devido à estabilidade e baixo efeito corrosivo para equipamentos e materiais. Glutaraldeído, apesar de muito aceito para processos esterilizantes, tem eficácia comparável a soluções de formaldeído.
topic Deseinfecção
Agentes desinfetantes
Tempo de redução decimal
Disinfection
Disinfectant agents
Decimal reduction time
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502009000400013
work_keys_str_mv AT priscilagavamazzola choiceofsterilizingdisinfectingagentdeterminationofthedecimalreductiontimedvalue
AT angelafaustinojozala choiceofsterilizingdisinfectingagentdeterminationofthedecimalreductiontimedvalue
AT leticiaceliadelencastrenovaes choiceofsterilizingdisinfectingagentdeterminationofthedecimalreductiontimedvalue
AT patriciamoriel choiceofsterilizingdisinfectingagentdeterminationofthedecimalreductiontimedvalue
AT therezachristinavessonipenna choiceofsterilizingdisinfectingagentdeterminationofthedecimalreductiontimedvalue
_version_ 1724849753928237056