A Tool for Thyroid and Breast Punch Biopsy

Background. Diagnosis of thyroid and mammary gland neoplasms is a persisting challenge. The common punch biopsy techniques exhibit significant drawbacks responsible for biasing the gland tumour inspection. The authors propose technical and methodological novelties in punch biopsy for improving the s...

Full description

Bibliographic Details
Main Authors: Z. M. Sigal, O. V. Surnina
Format: Article
Language:English
Published: Bashkir State Medical University 2021-04-01
Series:Креативная хирургия и онкология
Subjects:
Online Access:https://www.surgonco.ru/jour/article/view/565
id doaj-1207a5542214437ba61f7e5994b2cad2
record_format Article
spelling doaj-1207a5542214437ba61f7e5994b2cad22021-07-28T13:20:41ZengBashkir State Medical UniversityКреативная хирургия и онкология2307-05012076-30932021-04-01111202810.24060/2076-3093-2021-11-1-20-28412A Tool for Thyroid and Breast Punch BiopsyZ. M. Sigal0O. V. Surnina1Izhevsk State Medical AcademyIzhevsk State Medical Academy; Republican Clinical Diagnostic CentreBackground. Diagnosis of thyroid and mammary gland neoplasms is a persisting challenge. The common punch biopsy techniques exhibit significant drawbacks responsible for biasing the gland tumour inspection. The authors propose technical and methodological novelties in punch biopsy for improving the sensitivity and accuracy of neoplasm differential diagnosis in surgery.Materials and methods. A control cohort of 1406 patients had a conventional punch biopsy without ultrasonic guidance, whereas the study cohort of 1870 patients had puncturing with a novel device suitable for voluminous thyroid and mammary gland neoplasm biopsy.Results. A novel punch biopsy method is developed basing on the oscillation amplitude and tissue optical density determination. The novel puncture appliance and technique allowed an accuracy improvement of voluminous thyroid and mammary gland neoplasm puncture up to 90 %. No complications of thyroid neoplasm punch biopsy were observed in the study cohort. The control group exhibited the complications of impaired swallowing, local inflammation and haematomas at the puncture site.Discussion. The punch biopsy technique based on the pulse oscillation amplitude and optical tissue density measurement was proved to allow an earlier detection of voluminous neoplasms compared to visual inspection, while an additional canal allows concurrent biopsy of the lesion-adjacent tissue and the assessment of therapeutic efficacy and disease progression.Conclusion. Creative surgical approaches to punch biopsy based on emitter and optic sensor-geared pulse optometry and their implementing tool have been developed. The method improves the efficiency and accuracy of voluminous neoplasm differential diagnosis, provides control of treatment efficacy and prevents false positive and false negative detections.https://www.surgonco.ru/jour/article/view/565puncturepunch biopsyimage-guided biopsyultrasonographycomputed tomographythyroid neoplasmsmammary neoplasmspulse optometry
collection DOAJ
language English
format Article
sources DOAJ
author Z. M. Sigal
O. V. Surnina
spellingShingle Z. M. Sigal
O. V. Surnina
A Tool for Thyroid and Breast Punch Biopsy
Креативная хирургия и онкология
puncture
punch biopsy
image-guided biopsy
ultrasonography
computed tomography
thyroid neoplasms
mammary neoplasms
pulse optometry
author_facet Z. M. Sigal
O. V. Surnina
author_sort Z. M. Sigal
title A Tool for Thyroid and Breast Punch Biopsy
title_short A Tool for Thyroid and Breast Punch Biopsy
title_full A Tool for Thyroid and Breast Punch Biopsy
title_fullStr A Tool for Thyroid and Breast Punch Biopsy
title_full_unstemmed A Tool for Thyroid and Breast Punch Biopsy
title_sort tool for thyroid and breast punch biopsy
publisher Bashkir State Medical University
series Креативная хирургия и онкология
issn 2307-0501
2076-3093
publishDate 2021-04-01
description Background. Diagnosis of thyroid and mammary gland neoplasms is a persisting challenge. The common punch biopsy techniques exhibit significant drawbacks responsible for biasing the gland tumour inspection. The authors propose technical and methodological novelties in punch biopsy for improving the sensitivity and accuracy of neoplasm differential diagnosis in surgery.Materials and methods. A control cohort of 1406 patients had a conventional punch biopsy without ultrasonic guidance, whereas the study cohort of 1870 patients had puncturing with a novel device suitable for voluminous thyroid and mammary gland neoplasm biopsy.Results. A novel punch biopsy method is developed basing on the oscillation amplitude and tissue optical density determination. The novel puncture appliance and technique allowed an accuracy improvement of voluminous thyroid and mammary gland neoplasm puncture up to 90 %. No complications of thyroid neoplasm punch biopsy were observed in the study cohort. The control group exhibited the complications of impaired swallowing, local inflammation and haematomas at the puncture site.Discussion. The punch biopsy technique based on the pulse oscillation amplitude and optical tissue density measurement was proved to allow an earlier detection of voluminous neoplasms compared to visual inspection, while an additional canal allows concurrent biopsy of the lesion-adjacent tissue and the assessment of therapeutic efficacy and disease progression.Conclusion. Creative surgical approaches to punch biopsy based on emitter and optic sensor-geared pulse optometry and their implementing tool have been developed. The method improves the efficiency and accuracy of voluminous neoplasm differential diagnosis, provides control of treatment efficacy and prevents false positive and false negative detections.
topic puncture
punch biopsy
image-guided biopsy
ultrasonography
computed tomography
thyroid neoplasms
mammary neoplasms
pulse optometry
url https://www.surgonco.ru/jour/article/view/565
work_keys_str_mv AT zmsigal atoolforthyroidandbreastpunchbiopsy
AT ovsurnina atoolforthyroidandbreastpunchbiopsy
AT zmsigal toolforthyroidandbreastpunchbiopsy
AT ovsurnina toolforthyroidandbreastpunchbiopsy
_version_ 1721275490519482368