A Highly-sensitive Voltammetric Sensor for Scutellarin Based On Poly-taurine Film Modified Electrode
A highly-sensitive voltammetric sensor for scutellarin was fabricated via directly electro-polymerization of taurine at glassy carbon electrode. This sensor was simply obtained but displayed greatly improved response for scutellarin. The redox process of scutellarin was investigated systematically a...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
AIDIC Servizi S.r.l.
2017-09-01
|
Series: | Chemical Engineering Transactions |
Online Access: | https://www.cetjournal.it/index.php/cet/article/view/379 |
id |
doaj-11635446691c42059a8a75f8933f26cb |
---|---|
record_format |
Article |
spelling |
doaj-11635446691c42059a8a75f8933f26cb2021-02-18T20:58:10ZengAIDIC Servizi S.r.l.Chemical Engineering Transactions2283-92162017-09-016010.3303/CET1760004A Highly-sensitive Voltammetric Sensor for Scutellarin Based On Poly-taurine Film Modified Electrode Y. LiL. WeiL. DuH. ZhaoH. WangA highly-sensitive voltammetric sensor for scutellarin was fabricated via directly electro-polymerization of taurine at glassy carbon electrode. This sensor was simply obtained but displayed greatly improved response for scutellarin. The redox process of scutellarin was investigated systematically and some dynamic parameters of electrode reaction were calculated using electrochemical techniques in details. Under the optimum conditions, the linear range was from 8.0×10-8 to 4.0×10-6 mol L-1 with a low detectable limit 8.0×10-8 mol L-1. The proposed method was used to determine scutellarin in commercial pharmaceuticals with satisfactory results.. https://www.cetjournal.it/index.php/cet/article/view/379 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Y. Li L. Wei L. Du H. Zhao H. Wang |
spellingShingle |
Y. Li L. Wei L. Du H. Zhao H. Wang A Highly-sensitive Voltammetric Sensor for Scutellarin Based On Poly-taurine Film Modified Electrode Chemical Engineering Transactions |
author_facet |
Y. Li L. Wei L. Du H. Zhao H. Wang |
author_sort |
Y. Li |
title |
A Highly-sensitive Voltammetric Sensor for Scutellarin Based On Poly-taurine Film Modified Electrode
|
title_short |
A Highly-sensitive Voltammetric Sensor for Scutellarin Based On Poly-taurine Film Modified Electrode
|
title_full |
A Highly-sensitive Voltammetric Sensor for Scutellarin Based On Poly-taurine Film Modified Electrode
|
title_fullStr |
A Highly-sensitive Voltammetric Sensor for Scutellarin Based On Poly-taurine Film Modified Electrode
|
title_full_unstemmed |
A Highly-sensitive Voltammetric Sensor for Scutellarin Based On Poly-taurine Film Modified Electrode
|
title_sort |
highly-sensitive voltammetric sensor for scutellarin based on poly-taurine film modified electrode |
publisher |
AIDIC Servizi S.r.l. |
series |
Chemical Engineering Transactions |
issn |
2283-9216 |
publishDate |
2017-09-01 |
description |
A highly-sensitive voltammetric sensor for scutellarin was fabricated via directly electro-polymerization of taurine at glassy carbon electrode. This sensor was simply obtained but displayed greatly improved response for scutellarin. The redox process of scutellarin was investigated systematically and some dynamic parameters of electrode reaction were calculated using electrochemical techniques in details. Under the optimum conditions, the linear range was from 8.0×10-8 to 4.0×10-6 mol L-1 with a low detectable limit 8.0×10-8 mol L-1. The proposed method was used to determine scutellarin in commercial pharmaceuticals with satisfactory results..
|
url |
https://www.cetjournal.it/index.php/cet/article/view/379 |
work_keys_str_mv |
AT yli ahighlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode AT lwei ahighlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode AT ldu ahighlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode AT hzhao ahighlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode AT hwang ahighlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode AT yli highlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode AT lwei highlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode AT ldu highlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode AT hzhao highlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode AT hwang highlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode |
_version_ |
1724262359192567808 |