A Highly-sensitive Voltammetric Sensor for Scutellarin Based On Poly-taurine Film Modified Electrode

A highly-sensitive voltammetric sensor for scutellarin was fabricated via directly electro-polymerization of taurine at glassy carbon electrode. This sensor was simply obtained but displayed greatly improved response for scutellarin. The redox process of scutellarin was investigated systematically a...

Full description

Bibliographic Details
Main Authors: Y. Li, L. Wei, L. Du, H. Zhao, H. Wang
Format: Article
Language:English
Published: AIDIC Servizi S.r.l. 2017-09-01
Series:Chemical Engineering Transactions
Online Access:https://www.cetjournal.it/index.php/cet/article/view/379
id doaj-11635446691c42059a8a75f8933f26cb
record_format Article
spelling doaj-11635446691c42059a8a75f8933f26cb2021-02-18T20:58:10ZengAIDIC Servizi S.r.l.Chemical Engineering Transactions2283-92162017-09-016010.3303/CET1760004A Highly-sensitive Voltammetric Sensor for Scutellarin Based On Poly-taurine Film Modified Electrode Y. LiL. WeiL. DuH. ZhaoH. WangA highly-sensitive voltammetric sensor for scutellarin was fabricated via directly electro-polymerization of taurine at glassy carbon electrode. This sensor was simply obtained but displayed greatly improved response for scutellarin. The redox process of scutellarin was investigated systematically and some dynamic parameters of electrode reaction were calculated using electrochemical techniques in details. Under the optimum conditions, the linear range was from 8.0×10-8 to 4.0×10-6 mol L-1 with a low detectable limit 8.0×10-8 mol L-1. The proposed method was used to determine scutellarin in commercial pharmaceuticals with satisfactory results.. https://www.cetjournal.it/index.php/cet/article/view/379
collection DOAJ
language English
format Article
sources DOAJ
author Y. Li
L. Wei
L. Du
H. Zhao
H. Wang
spellingShingle Y. Li
L. Wei
L. Du
H. Zhao
H. Wang
A Highly-sensitive Voltammetric Sensor for Scutellarin Based On Poly-taurine Film Modified Electrode
Chemical Engineering Transactions
author_facet Y. Li
L. Wei
L. Du
H. Zhao
H. Wang
author_sort Y. Li
title A Highly-sensitive Voltammetric Sensor for Scutellarin Based On Poly-taurine Film Modified Electrode
title_short A Highly-sensitive Voltammetric Sensor for Scutellarin Based On Poly-taurine Film Modified Electrode
title_full A Highly-sensitive Voltammetric Sensor for Scutellarin Based On Poly-taurine Film Modified Electrode
title_fullStr A Highly-sensitive Voltammetric Sensor for Scutellarin Based On Poly-taurine Film Modified Electrode
title_full_unstemmed A Highly-sensitive Voltammetric Sensor for Scutellarin Based On Poly-taurine Film Modified Electrode
title_sort highly-sensitive voltammetric sensor for scutellarin based on poly-taurine film modified electrode
publisher AIDIC Servizi S.r.l.
series Chemical Engineering Transactions
issn 2283-9216
publishDate 2017-09-01
description A highly-sensitive voltammetric sensor for scutellarin was fabricated via directly electro-polymerization of taurine at glassy carbon electrode. This sensor was simply obtained but displayed greatly improved response for scutellarin. The redox process of scutellarin was investigated systematically and some dynamic parameters of electrode reaction were calculated using electrochemical techniques in details. Under the optimum conditions, the linear range was from 8.0×10-8 to 4.0×10-6 mol L-1 with a low detectable limit 8.0×10-8 mol L-1. The proposed method was used to determine scutellarin in commercial pharmaceuticals with satisfactory results..
url https://www.cetjournal.it/index.php/cet/article/view/379
work_keys_str_mv AT yli ahighlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode
AT lwei ahighlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode
AT ldu ahighlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode
AT hzhao ahighlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode
AT hwang ahighlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode
AT yli highlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode
AT lwei highlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode
AT ldu highlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode
AT hzhao highlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode
AT hwang highlysensitivevoltammetricsensorforscutellarinbasedonpolytaurinefilmmodifiedelectrode
_version_ 1724262359192567808