The influence of sample preparation quality on the results of spectral analysis

Сonsiders the possibility of analyzing samples of small diameters without the use of special adapters for determining the chemical composition on spectrometers. Measurements are limited to the size of the hole on the analytical table, which is 12 mm. Accordingly, all analyzed samples must have a dia...

Full description

Bibliographic Details
Main Author: M. V. Lagoyskaya
Format: Article
Language:English
Published: Belarusian National Technical University 2020-01-01
Series:Litʹë i Metallurgiâ
Subjects:
Online Access:https://lim.bntu.by/jour/article/view/3155
id doaj-11433a18df2e4b7c81ddc105cd7ba821
record_format Article
spelling doaj-11433a18df2e4b7c81ddc105cd7ba8212021-07-29T08:34:08ZengBelarusian National Technical UniversityLitʹë i Metallurgiâ1683-60652414-04062020-01-0104727510.21122/1683-6065-2019-4-72-753065The influence of sample preparation quality on the results of spectral analysisM. V. Lagoyskaya0BSW – Management Company of the Holding «BMC»Сonsiders the possibility of analyzing samples of small diameters without the use of special adapters for determining the chemical composition on spectrometers. Measurements are limited to the size of the hole on the analytical table, which is 12 mm. Accordingly, all analyzed samples must have a diameter of at least 14 mm to completely cover the sample cover of the discharge chamber in order to avoid air entering the chamber. The company manufacturer of spectral equipment offers to use special adapters for the analysis of small samples. But the use of such adapters has a number of drawbacks. These include additional cash costs for the purchase of adapters, the need for additional standardization procedures, the availability of special reference samples. In the laboratory of analytical support (LAS) of the Central Laboratory of the Factory (CLF), all samples of finished rolled products (wire rods or fittings) in size from 5.5 mm to 20 mm are prepared in the form of «blades». The compressed part of the «blade» is the analyzed surface of the sample, which is further processed on a disk grinder and transmitted to the spectral analysis. The article presents the results of comparative tests of valves class U500 between samples in the form of «blades» and in the form of «columns» and concluded that the necessity of use of special adapters.https://lim.bntu.by/jour/article/view/3155sample preparationchemical compositionspectral analysisoptical emission spectrometersmall diameter rollingadapter
collection DOAJ
language English
format Article
sources DOAJ
author M. V. Lagoyskaya
spellingShingle M. V. Lagoyskaya
The influence of sample preparation quality on the results of spectral analysis
Litʹë i Metallurgiâ
sample preparation
chemical composition
spectral analysis
optical emission spectrometer
small diameter rolling
adapter
author_facet M. V. Lagoyskaya
author_sort M. V. Lagoyskaya
title The influence of sample preparation quality on the results of spectral analysis
title_short The influence of sample preparation quality on the results of spectral analysis
title_full The influence of sample preparation quality on the results of spectral analysis
title_fullStr The influence of sample preparation quality on the results of spectral analysis
title_full_unstemmed The influence of sample preparation quality on the results of spectral analysis
title_sort influence of sample preparation quality on the results of spectral analysis
publisher Belarusian National Technical University
series Litʹë i Metallurgiâ
issn 1683-6065
2414-0406
publishDate 2020-01-01
description Сonsiders the possibility of analyzing samples of small diameters without the use of special adapters for determining the chemical composition on spectrometers. Measurements are limited to the size of the hole on the analytical table, which is 12 mm. Accordingly, all analyzed samples must have a diameter of at least 14 mm to completely cover the sample cover of the discharge chamber in order to avoid air entering the chamber. The company manufacturer of spectral equipment offers to use special adapters for the analysis of small samples. But the use of such adapters has a number of drawbacks. These include additional cash costs for the purchase of adapters, the need for additional standardization procedures, the availability of special reference samples. In the laboratory of analytical support (LAS) of the Central Laboratory of the Factory (CLF), all samples of finished rolled products (wire rods or fittings) in size from 5.5 mm to 20 mm are prepared in the form of «blades». The compressed part of the «blade» is the analyzed surface of the sample, which is further processed on a disk grinder and transmitted to the spectral analysis. The article presents the results of comparative tests of valves class U500 between samples in the form of «blades» and in the form of «columns» and concluded that the necessity of use of special adapters.
topic sample preparation
chemical composition
spectral analysis
optical emission spectrometer
small diameter rolling
adapter
url https://lim.bntu.by/jour/article/view/3155
work_keys_str_mv AT mvlagoyskaya theinfluenceofsamplepreparationqualityontheresultsofspectralanalysis
AT mvlagoyskaya influenceofsamplepreparationqualityontheresultsofspectralanalysis
_version_ 1721254229395374080