Simultaneous Quantification of Chosen Organic Micropollutants in Drinking Water
An analytical method that can allow one to determine simultaneously chosen organic micropollutants has been developed to measure their concentrations in water. Standard mixture of 16 polycyclic aromatic hydrocarbons (PAH) and nine polychlorinated biphenyls (PCB) was added to distilled water in a spe...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2019-06-01
|
Series: | Proceedings |
Subjects: | |
Online Access: | https://www.mdpi.com/2504-3900/16/1/8 |
id |
doaj-113a5d05bfcc47af872a4ce933181c20 |
---|---|
record_format |
Article |
spelling |
doaj-113a5d05bfcc47af872a4ce933181c202020-11-25T01:11:16ZengMDPI AGProceedings2504-39002019-06-01161810.3390/proceedings2019016008proceedings2019016008Simultaneous Quantification of Chosen Organic Micropollutants in Drinking WaterPatrycja Sobczak0Agata Rosińska1Department of Chemistry, Water and Wastewater Technology, Faculty of Infrastructure and Environment, Częstochowa University of Technology, Dąbrowskiego 69 Str, 42-200 Częstochowa, PolandDepartment of Chemistry, Water and Wastewater Technology, Faculty of Infrastructure and Environment, Częstochowa University of Technology, Dąbrowskiego 69 Str, 42-200 Częstochowa, PolandAn analytical method that can allow one to determine simultaneously chosen organic micropollutants has been developed to measure their concentrations in water. Standard mixture of 16 polycyclic aromatic hydrocarbons (PAH) and nine polychlorinated biphenyls (PCB) was added to distilled water in a specific amount. The solid phase extraction (SPE) method was applied. Isopropyl alcohol and methanol were used to precondition SPE extraction columns. PAH and PCB were eluted from the column fillings using dichloromethane. Extracts were condensed to a volume of 2 mL. Prepared samples were analyzed with the use of gas chromatography and mass spectrometry. The achieved percent recovery of PAH was from around 7% in the case of chrysene to 100% in the case of naphthalene. The achieved percent recovery of PCB was from about 51% in the case of PCB 101 to 92% in the case of PCB 156.https://www.mdpi.com/2504-3900/16/1/8organic micropollutantspolycyclic aromatic hydrocarbonspolychlorinated biphenylsdrinking watersurface water |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Patrycja Sobczak Agata Rosińska |
spellingShingle |
Patrycja Sobczak Agata Rosińska Simultaneous Quantification of Chosen Organic Micropollutants in Drinking Water Proceedings organic micropollutants polycyclic aromatic hydrocarbons polychlorinated biphenyls drinking water surface water |
author_facet |
Patrycja Sobczak Agata Rosińska |
author_sort |
Patrycja Sobczak |
title |
Simultaneous Quantification of Chosen Organic Micropollutants in Drinking Water |
title_short |
Simultaneous Quantification of Chosen Organic Micropollutants in Drinking Water |
title_full |
Simultaneous Quantification of Chosen Organic Micropollutants in Drinking Water |
title_fullStr |
Simultaneous Quantification of Chosen Organic Micropollutants in Drinking Water |
title_full_unstemmed |
Simultaneous Quantification of Chosen Organic Micropollutants in Drinking Water |
title_sort |
simultaneous quantification of chosen organic micropollutants in drinking water |
publisher |
MDPI AG |
series |
Proceedings |
issn |
2504-3900 |
publishDate |
2019-06-01 |
description |
An analytical method that can allow one to determine simultaneously chosen organic micropollutants has been developed to measure their concentrations in water. Standard mixture of 16 polycyclic aromatic hydrocarbons (PAH) and nine polychlorinated biphenyls (PCB) was added to distilled water in a specific amount. The solid phase extraction (SPE) method was applied. Isopropyl alcohol and methanol were used to precondition SPE extraction columns. PAH and PCB were eluted from the column fillings using dichloromethane. Extracts were condensed to a volume of 2 mL. Prepared samples were analyzed with the use of gas chromatography and mass spectrometry. The achieved percent recovery of PAH was from around 7% in the case of chrysene to 100% in the case of naphthalene. The achieved percent recovery of PCB was from about 51% in the case of PCB 101 to 92% in the case of PCB 156. |
topic |
organic micropollutants polycyclic aromatic hydrocarbons polychlorinated biphenyls drinking water surface water |
url |
https://www.mdpi.com/2504-3900/16/1/8 |
work_keys_str_mv |
AT patrycjasobczak simultaneousquantificationofchosenorganicmicropollutantsindrinkingwater AT agatarosinska simultaneousquantificationofchosenorganicmicropollutantsindrinkingwater |
_version_ |
1725171962778484736 |