Frontal suspension for congenital ptosis using an expanded polytetrafluoroethylene (Gore-Tex®) sheet: one-year follow-up

Kazuaki Nakauchi,1 Hidenori Mito,2 Osamu Mimura11Hospital of Hyogo College of Medicine, Hyogo, 2Ide Eye Hospital, Yamagata, JapanBackground: The frontalis suspension technique is the surgical method of choice in patients with ptosis and a levator function of 4 mm or less. Several types of materials...

Full description

Bibliographic Details
Main Authors: Nakauchi K, Mito H, Mimura O
Format: Article
Language:English
Published: Dove Medical Press 2013-01-01
Series:Clinical Ophthalmology
Online Access:http://www.dovepress.com/frontal-suspension-for-congenital-ptosis-using-an-expanded-polytetrafl-a11963
id doaj-1106eba3fe774ddfac0c6af7edc6e623
record_format Article
spelling doaj-1106eba3fe774ddfac0c6af7edc6e6232020-11-25T02:49:13ZengDove Medical PressClinical Ophthalmology1177-54671177-54832013-01-012013default131136Frontal suspension for congenital ptosis using an expanded polytetrafluoroethylene (Gore-Tex®) sheet: one-year follow-upNakauchi KMito HMimura OKazuaki Nakauchi,1 Hidenori Mito,2 Osamu Mimura11Hospital of Hyogo College of Medicine, Hyogo, 2Ide Eye Hospital, Yamagata, JapanBackground: The frontalis suspension technique is the surgical method of choice in patients with ptosis and a levator function of 4 mm or less. Several types of materials have been used, including Gore-Tex®, which has been used successfully as a frontalis sling material since 1986. Recently, a Gore-Tex sheet (wider than a sling or strip) suspension was reported. This paper reports the results of 27 eyes from 20 patients with congenital ptosis treated using the frontalis suspension technique with the newly developed Gore-Tex Most Versatile Patch (MVP) sheet.Methods: All patients underwent surgery between April 2007 and September 2011 and were followed up for at least one year. The average follow-up duration was 18 months, with a range of 12–36 months. The average patient age was 45 (5–85) years, and the group included 11 males and nine females. Thirteen cases demonstrated ptosis in one eye, and seven cases involved both eyes. The patients were divided by age into a younger group and an older group. All ptosis procedures were performed using the Gore-Tex MVP sheet. The implant was normally 7 mm wide for adults and 5 mm wide for children. The implantation method was the same as that used for the sheet shape fascia.Results: In all patients, satisfactory functional results were observed at the 6-month follow-up examination. Eyelid opening heights were also obtained. The average marginal reflex distance (MRD) was -0.5 mm preoperatively, which improved to +1.9 mm after surgery. After one year, average MRD was +1.6 mm. MRD attenuation was more frequent in the younger group. There were no cases requiring redo surgery and only one case of exposure.Keywords: polytetrafluoroethylene, Gore-Tex®, frontalis suspension, congenital ptosis, recurrencehttp://www.dovepress.com/frontal-suspension-for-congenital-ptosis-using-an-expanded-polytetrafl-a11963
collection DOAJ
language English
format Article
sources DOAJ
author Nakauchi K
Mito H
Mimura O
spellingShingle Nakauchi K
Mito H
Mimura O
Frontal suspension for congenital ptosis using an expanded polytetrafluoroethylene (Gore-Tex®) sheet: one-year follow-up
Clinical Ophthalmology
author_facet Nakauchi K
Mito H
Mimura O
author_sort Nakauchi K
title Frontal suspension for congenital ptosis using an expanded polytetrafluoroethylene (Gore-Tex®) sheet: one-year follow-up
title_short Frontal suspension for congenital ptosis using an expanded polytetrafluoroethylene (Gore-Tex®) sheet: one-year follow-up
title_full Frontal suspension for congenital ptosis using an expanded polytetrafluoroethylene (Gore-Tex®) sheet: one-year follow-up
title_fullStr Frontal suspension for congenital ptosis using an expanded polytetrafluoroethylene (Gore-Tex®) sheet: one-year follow-up
title_full_unstemmed Frontal suspension for congenital ptosis using an expanded polytetrafluoroethylene (Gore-Tex®) sheet: one-year follow-up
title_sort frontal suspension for congenital ptosis using an expanded polytetrafluoroethylene (gore-tex®) sheet: one-year follow-up
publisher Dove Medical Press
series Clinical Ophthalmology
issn 1177-5467
1177-5483
publishDate 2013-01-01
description Kazuaki Nakauchi,1 Hidenori Mito,2 Osamu Mimura11Hospital of Hyogo College of Medicine, Hyogo, 2Ide Eye Hospital, Yamagata, JapanBackground: The frontalis suspension technique is the surgical method of choice in patients with ptosis and a levator function of 4 mm or less. Several types of materials have been used, including Gore-Tex®, which has been used successfully as a frontalis sling material since 1986. Recently, a Gore-Tex sheet (wider than a sling or strip) suspension was reported. This paper reports the results of 27 eyes from 20 patients with congenital ptosis treated using the frontalis suspension technique with the newly developed Gore-Tex Most Versatile Patch (MVP) sheet.Methods: All patients underwent surgery between April 2007 and September 2011 and were followed up for at least one year. The average follow-up duration was 18 months, with a range of 12–36 months. The average patient age was 45 (5–85) years, and the group included 11 males and nine females. Thirteen cases demonstrated ptosis in one eye, and seven cases involved both eyes. The patients were divided by age into a younger group and an older group. All ptosis procedures were performed using the Gore-Tex MVP sheet. The implant was normally 7 mm wide for adults and 5 mm wide for children. The implantation method was the same as that used for the sheet shape fascia.Results: In all patients, satisfactory functional results were observed at the 6-month follow-up examination. Eyelid opening heights were also obtained. The average marginal reflex distance (MRD) was -0.5 mm preoperatively, which improved to +1.9 mm after surgery. After one year, average MRD was +1.6 mm. MRD attenuation was more frequent in the younger group. There were no cases requiring redo surgery and only one case of exposure.Keywords: polytetrafluoroethylene, Gore-Tex®, frontalis suspension, congenital ptosis, recurrence
url http://www.dovepress.com/frontal-suspension-for-congenital-ptosis-using-an-expanded-polytetrafl-a11963
work_keys_str_mv AT nakauchik frontalsuspensionforcongenitalptosisusinganexpandedpolytetrafluoroethylenegoretexampregsheetoneyearfollowup
AT mitoh frontalsuspensionforcongenitalptosisusinganexpandedpolytetrafluoroethylenegoretexampregsheetoneyearfollowup
AT mimurao frontalsuspensionforcongenitalptosisusinganexpandedpolytetrafluoroethylenegoretexampregsheetoneyearfollowup
_version_ 1724744819507462144