INFLUENCE OF DYNAMIC MAGNETIZATION TO IMPROVE THE EFFICIENCY OF ELECTROMAGNETIC-ACOUSTIC TRANSFORMATION WITH WAVEGUIDE CONTROL RODS
The disadvantage of the electromagnetic-acoustic (EMA) method receiving ultrasonic waves are low efficiency. The traditional way to enhance its effectiveness is increase the bias field. The aim of the study was research the way to improve the efficiency of the EMA transformation, using a time-varyin...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Belarusian National Technical University
2017-09-01
|
Series: | Pribory i Metody Izmerenij |
Subjects: | |
Online Access: | https://pimi.bntu.by/jour/article/view/329 |
id |
doaj-1098eb58685e4bbfb29d0c708869de00 |
---|---|
record_format |
Article |
spelling |
doaj-1098eb58685e4bbfb29d0c708869de002021-07-29T08:39:10ZengBelarusian National Technical UniversityPribory i Metody Izmerenij2220-95062414-04732017-09-018323624510.21122/2220-9506-2017-8-3-236-245284INFLUENCE OF DYNAMIC MAGNETIZATION TO IMPROVE THE EFFICIENCY OF ELECTROMAGNETIC-ACOUSTIC TRANSFORMATION WITH WAVEGUIDE CONTROL RODSD. V. Zlobin0L. V. Volkova1Kalashnikov Izhevsk State Technical UniversityKalashnikov Izhevsk State Technical UniversityThe disadvantage of the electromagnetic-acoustic (EMA) method receiving ultrasonic waves are low efficiency. The traditional way to enhance its effectiveness is increase the bias field. The aim of the study was research the way to improve the efficiency of the EMA transformation, using a time-varying bias field.The researches held with the help of a specially designed installation that allows the magnetization to be performed by a constant and alternating magnetic field (dynamic bias), synchronously with the passage of the received pulse. The object of the study were rods made of different grades of steel with a diameter of 4–6 mm, in which the symmetrical zero mode S0 of the rod wave was excited by the EMA method (in the frequency range of about 40 kHz). A comparative analysis of the amplitudes and form pulses of multiple reflections during static and dynamic reversal of magnetization and with a full cycle of magnetization reversal conducted.The result of the efficiency measurements EMA reception during static and dynamic bias found a significant (up to 5 times) increase in the signal amplitude on the receiving transducer. Taking into account that the main contribution to the excitation mechanism and the reception mechanism made the magnetostrictive effect on low frecuncy, it can assumed that using a dynamic bias field is impacting significant on the effective mobility of magnetic domains (that is changes the dynamic magnetic susceptibility of the material). It is established that it is possible to monitor steel at lower values of the bias field, and, consequently, to reduce the mass dimensions of the magnetic system.Thus, in the course of the researchers found of effect of dynamic bias and effect of dynamic bias increase acoustic pulse amplitude of the signal of the received EMA method. Using this method will improve the quality EMA testing by creating more efficient EMA transducer. Taking into account that the value of the detected effect depends significantly on the steel grade, we can assume its possible application in the methods of express analysis, estimation of structural and stressed states.https://pimi.bntu.by/jour/article/view/329linearly extended objectsthe effectiveness of electromagnetic-acoustic conversiondynamic biasingthe bias coil |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
D. V. Zlobin L. V. Volkova |
spellingShingle |
D. V. Zlobin L. V. Volkova INFLUENCE OF DYNAMIC MAGNETIZATION TO IMPROVE THE EFFICIENCY OF ELECTROMAGNETIC-ACOUSTIC TRANSFORMATION WITH WAVEGUIDE CONTROL RODS Pribory i Metody Izmerenij linearly extended objects the effectiveness of electromagnetic-acoustic conversion dynamic biasing the bias coil |
author_facet |
D. V. Zlobin L. V. Volkova |
author_sort |
D. V. Zlobin |
title |
INFLUENCE OF DYNAMIC MAGNETIZATION TO IMPROVE THE EFFICIENCY OF ELECTROMAGNETIC-ACOUSTIC TRANSFORMATION WITH WAVEGUIDE CONTROL RODS |
title_short |
INFLUENCE OF DYNAMIC MAGNETIZATION TO IMPROVE THE EFFICIENCY OF ELECTROMAGNETIC-ACOUSTIC TRANSFORMATION WITH WAVEGUIDE CONTROL RODS |
title_full |
INFLUENCE OF DYNAMIC MAGNETIZATION TO IMPROVE THE EFFICIENCY OF ELECTROMAGNETIC-ACOUSTIC TRANSFORMATION WITH WAVEGUIDE CONTROL RODS |
title_fullStr |
INFLUENCE OF DYNAMIC MAGNETIZATION TO IMPROVE THE EFFICIENCY OF ELECTROMAGNETIC-ACOUSTIC TRANSFORMATION WITH WAVEGUIDE CONTROL RODS |
title_full_unstemmed |
INFLUENCE OF DYNAMIC MAGNETIZATION TO IMPROVE THE EFFICIENCY OF ELECTROMAGNETIC-ACOUSTIC TRANSFORMATION WITH WAVEGUIDE CONTROL RODS |
title_sort |
influence of dynamic magnetization to improve the efficiency of electromagnetic-acoustic transformation with waveguide control rods |
publisher |
Belarusian National Technical University |
series |
Pribory i Metody Izmerenij |
issn |
2220-9506 2414-0473 |
publishDate |
2017-09-01 |
description |
The disadvantage of the electromagnetic-acoustic (EMA) method receiving ultrasonic waves are low efficiency. The traditional way to enhance its effectiveness is increase the bias field. The aim of the study was research the way to improve the efficiency of the EMA transformation, using a time-varying bias field.The researches held with the help of a specially designed installation that allows the magnetization to be performed by a constant and alternating magnetic field (dynamic bias), synchronously with the passage of the received pulse. The object of the study were rods made of different grades of steel with a diameter of 4–6 mm, in which the symmetrical zero mode S0 of the rod wave was excited by the EMA method (in the frequency range of about 40 kHz). A comparative analysis of the amplitudes and form pulses of multiple reflections during static and dynamic reversal of magnetization and with a full cycle of magnetization reversal conducted.The result of the efficiency measurements EMA reception during static and dynamic bias found a significant (up to 5 times) increase in the signal amplitude on the receiving transducer. Taking into account that the main contribution to the excitation mechanism and the reception mechanism made the magnetostrictive effect on low frecuncy, it can assumed that using a dynamic bias field is impacting significant on the effective mobility of magnetic domains (that is changes the dynamic magnetic susceptibility of the material). It is established that it is possible to monitor steel at lower values of the bias field, and, consequently, to reduce the mass dimensions of the magnetic system.Thus, in the course of the researchers found of effect of dynamic bias and effect of dynamic bias increase acoustic pulse amplitude of the signal of the received EMA method. Using this method will improve the quality EMA testing by creating more efficient EMA transducer. Taking into account that the value of the detected effect depends significantly on the steel grade, we can assume its possible application in the methods of express analysis, estimation of structural and stressed states. |
topic |
linearly extended objects the effectiveness of electromagnetic-acoustic conversion dynamic biasing the bias coil |
url |
https://pimi.bntu.by/jour/article/view/329 |
work_keys_str_mv |
AT dvzlobin influenceofdynamicmagnetizationtoimprovetheefficiencyofelectromagneticacoustictransformationwithwaveguidecontrolrods AT lvvolkova influenceofdynamicmagnetizationtoimprovetheefficiencyofelectromagneticacoustictransformationwithwaveguidecontrolrods |
_version_ |
1721252865190658048 |