Cracked reinforced concrete walls of chimneys, silos and cooling towers as result of using formworks

There are presented in this paper some problems connected with reinforced concrete shell objects operation in the aggressive environment and built in method of formworks. Reinforced concrete chimneys, cooling towers, silos and other shells were built for decades. Durability of cracked shells are one...

Full description

Bibliographic Details
Main Authors: Maj Marek, Ubysz Andrzej
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:MATEC Web of Conferences
Online Access:https://doi.org/10.1051/matecconf/201814602002
id doaj-1080577285984f149c018fdd8726a836
record_format Article
spelling doaj-1080577285984f149c018fdd8726a8362021-02-02T07:34:45ZengEDP SciencesMATEC Web of Conferences2261-236X2018-01-011460200210.1051/matecconf/201814602002matecconf_bd2018_02002Cracked reinforced concrete walls of chimneys, silos and cooling towers as result of using formworksMaj MarekUbysz AndrzejThere are presented in this paper some problems connected with reinforced concrete shell objects operation in the aggressive environment and built in method of formworks. Reinforced concrete chimneys, cooling towers, silos and other shells were built for decades. Durability of cracked shells are one of the most important parameters during process of designing, construction and exploitation of shells. Some reasons of appearance of horizontal and vertical cracks as temperature, pressure of stored material, live loads e.g. dynamic character of wind, moisture, influence of construction joints, thermal insulation, chemistry active environmental etc. reduce the carrying capacity of the walls. Formworks, as is occurred recently, are the reason for technological joints with leaking connection, imperfections of flexible formworks slabs and as result can initiate cracks. Cracked surface of this constructions causes decreasing capacity and lower the state of reliability. Horizontal, vertical cracks can caused corrosion of concrete and steel bars, decreasing stiffness of contraction, increasing of deflection and carbonation of concrete cover. Local and global imperfactions of concrete shells are increasing according to greater number of cracks...https://doi.org/10.1051/matecconf/201814602002
collection DOAJ
language English
format Article
sources DOAJ
author Maj Marek
Ubysz Andrzej
spellingShingle Maj Marek
Ubysz Andrzej
Cracked reinforced concrete walls of chimneys, silos and cooling towers as result of using formworks
MATEC Web of Conferences
author_facet Maj Marek
Ubysz Andrzej
author_sort Maj Marek
title Cracked reinforced concrete walls of chimneys, silos and cooling towers as result of using formworks
title_short Cracked reinforced concrete walls of chimneys, silos and cooling towers as result of using formworks
title_full Cracked reinforced concrete walls of chimneys, silos and cooling towers as result of using formworks
title_fullStr Cracked reinforced concrete walls of chimneys, silos and cooling towers as result of using formworks
title_full_unstemmed Cracked reinforced concrete walls of chimneys, silos and cooling towers as result of using formworks
title_sort cracked reinforced concrete walls of chimneys, silos and cooling towers as result of using formworks
publisher EDP Sciences
series MATEC Web of Conferences
issn 2261-236X
publishDate 2018-01-01
description There are presented in this paper some problems connected with reinforced concrete shell objects operation in the aggressive environment and built in method of formworks. Reinforced concrete chimneys, cooling towers, silos and other shells were built for decades. Durability of cracked shells are one of the most important parameters during process of designing, construction and exploitation of shells. Some reasons of appearance of horizontal and vertical cracks as temperature, pressure of stored material, live loads e.g. dynamic character of wind, moisture, influence of construction joints, thermal insulation, chemistry active environmental etc. reduce the carrying capacity of the walls. Formworks, as is occurred recently, are the reason for technological joints with leaking connection, imperfections of flexible formworks slabs and as result can initiate cracks. Cracked surface of this constructions causes decreasing capacity and lower the state of reliability. Horizontal, vertical cracks can caused corrosion of concrete and steel bars, decreasing stiffness of contraction, increasing of deflection and carbonation of concrete cover. Local and global imperfactions of concrete shells are increasing according to greater number of cracks...
url https://doi.org/10.1051/matecconf/201814602002
work_keys_str_mv AT majmarek crackedreinforcedconcretewallsofchimneyssilosandcoolingtowersasresultofusingformworks
AT ubyszandrzej crackedreinforcedconcretewallsofchimneyssilosandcoolingtowersasresultofusingformworks
_version_ 1724299069926408192