Influence Factors Analysis of RC Beams under Falling Weight Impact Based on HJC Model
Impact loads may cause serious or even fatal damage to the structure (component), in most existing specifications in China, and there are no special terms that take impact load into consideration. So, the response analysis of the structure (component) under impact loads is very important. In this pa...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2018-01-01
|
Series: | Shock and Vibration |
Online Access: | http://dx.doi.org/10.1155/2018/4731863 |
id |
doaj-107213b26bc7494aa4e19376c80a7f7c |
---|---|
record_format |
Article |
spelling |
doaj-107213b26bc7494aa4e19376c80a7f7c2020-11-25T00:43:33ZengHindawi LimitedShock and Vibration1070-96221875-92032018-01-01201810.1155/2018/47318634731863Influence Factors Analysis of RC Beams under Falling Weight Impact Based on HJC ModelXiaohong Long0Ahmed Turgun1Rong Yue2Yongtao Ma3Hui Luo4School of Civil Engineering and Mechanics, Huazhong University of Science and Technology, Wuhan 430074, ChinaSchool of Civil Engineering and Mechanics, Huazhong University of Science and Technology, Wuhan 430074, ChinaSchool of Civil Engineering and Mechanics, Huazhong University of Science and Technology, Wuhan 430074, ChinaSchool of Civil Engineering and Mechanics, Huazhong University of Science and Technology, Wuhan 430074, ChinaSchool of Civil Engineering and Mechanics, Huazhong University of Science and Technology, Wuhan 430074, ChinaImpact loads may cause serious or even fatal damage to the structure (component), in most existing specifications in China, and there are no special terms that take impact load into consideration. So, the response analysis of the structure (component) under impact loads is very important. In this paper, the sensitivity analysis was conducted for the 22 parameters of the Holmquist–Johnson concrete (HJC) constitutive model of concrete, and the sensitive parameters of the HJC model are identified with A, B, G, Pl, μl, and fc respectively. LS-DYNA nonlinear transient finite element analysis code was used for this paper. Based on the validation of finite element modeling and choosing midspan deflection of RC beams and impact loads as response indices, some influencing factors on RC beams under falling weight impact were investigated, such as the mass and speed of falling weight, impact position, the strength of concrete and rebar, longitudinal reinforcement ratio, and the span of the beam.http://dx.doi.org/10.1155/2018/4731863 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Xiaohong Long Ahmed Turgun Rong Yue Yongtao Ma Hui Luo |
spellingShingle |
Xiaohong Long Ahmed Turgun Rong Yue Yongtao Ma Hui Luo Influence Factors Analysis of RC Beams under Falling Weight Impact Based on HJC Model Shock and Vibration |
author_facet |
Xiaohong Long Ahmed Turgun Rong Yue Yongtao Ma Hui Luo |
author_sort |
Xiaohong Long |
title |
Influence Factors Analysis of RC Beams under Falling Weight Impact Based on HJC Model |
title_short |
Influence Factors Analysis of RC Beams under Falling Weight Impact Based on HJC Model |
title_full |
Influence Factors Analysis of RC Beams under Falling Weight Impact Based on HJC Model |
title_fullStr |
Influence Factors Analysis of RC Beams under Falling Weight Impact Based on HJC Model |
title_full_unstemmed |
Influence Factors Analysis of RC Beams under Falling Weight Impact Based on HJC Model |
title_sort |
influence factors analysis of rc beams under falling weight impact based on hjc model |
publisher |
Hindawi Limited |
series |
Shock and Vibration |
issn |
1070-9622 1875-9203 |
publishDate |
2018-01-01 |
description |
Impact loads may cause serious or even fatal damage to the structure (component), in most existing specifications in China, and there are no special terms that take impact load into consideration. So, the response analysis of the structure (component) under impact loads is very important. In this paper, the sensitivity analysis was conducted for the 22 parameters of the Holmquist–Johnson concrete (HJC) constitutive model of concrete, and the sensitive parameters of the HJC model are identified with A, B, G, Pl, μl, and fc respectively. LS-DYNA nonlinear transient finite element analysis code was used for this paper. Based on the validation of finite element modeling and choosing midspan deflection of RC beams and impact loads as response indices, some influencing factors on RC beams under falling weight impact were investigated, such as the mass and speed of falling weight, impact position, the strength of concrete and rebar, longitudinal reinforcement ratio, and the span of the beam. |
url |
http://dx.doi.org/10.1155/2018/4731863 |
work_keys_str_mv |
AT xiaohonglong influencefactorsanalysisofrcbeamsunderfallingweightimpactbasedonhjcmodel AT ahmedturgun influencefactorsanalysisofrcbeamsunderfallingweightimpactbasedonhjcmodel AT rongyue influencefactorsanalysisofrcbeamsunderfallingweightimpactbasedonhjcmodel AT yongtaoma influencefactorsanalysisofrcbeamsunderfallingweightimpactbasedonhjcmodel AT huiluo influencefactorsanalysisofrcbeamsunderfallingweightimpactbasedonhjcmodel |
_version_ |
1725277812111179776 |